Desa DVFH34P Installing Optional Wall Mount Switch GWMS2, REMOVING/REPLACING Glass Door

Page 22

DVFH34, DVFH34P

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

FIREPLACE INSTALLATION

Continued

4.Route the wire through openings pro- vided on the sides of the fireplace to a convenient location to mount your ther- mostat (no outside wall).

IMPORTANT: The wire may be short- ened but must not be lengthened.

The thermostat should be mounted 54" above the floor in a location where there is good air circulation. Avoid heat sources such as lamps, direct sunlight, fireplace, or heat and air conditioning ducts.

5.Gently remove the cover of the ther- mostat from the base. Grasp the sides of the cover firmly and pull to separate from the base.

6.Feed the electrical wires through the rectangular slots (from the back) on each side of the base (see Figure 45).

WARNING: Do not connect this thermostat to a power source. Electrical shock and/or fire haz- ard will occur.

7.Connect one bare wire end to each ter- minal (“W” and “R”) of the thermostat base (see Figure 46).

8.Install the base to the wall with screws provided with thermostat.

9.Move the temperature adjustment back and forth to insure the bimetal is free from restrictions.

10.Replace the cover onto the base. (Upon installation, the thermostat must be al- lowed to stabilize at room temperature for a minimum of 30 minutes for proper operation.)

11.Set the temperature adjustment to the desired setting.

This thermostat has been electronically calibrated at the factory. No adjustment or leveling is necessary.

Feed wires through rectangular slots

Figure 45 - Back View of Thermostat Base

 

Terminal “W”

W

R

Terminal “R”

Figure 46 - Thermostat Base Terminals “W” and “R”

INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2

NOTICE: The GWMS2 includes 25' of wire for installation. Your fireplace includes 15' of wire for accessory installation. Choose the length that best fits your needs when installing this accessory.

1.Connect one terminal of the provided wire for the wall switch to the TPTH terminal on the valve. Connect remain- ing wire terminal to the TH terminal on the valve. Make sure that the wire terminals are in the positions on the unit as pictured in Figure 41, page 21. If wires are not connected as shown the switch will not work.

2.Route the wire through openings pro- vided on the sides of the fireplace to a convenient location to mount your switch.

3.Connect one bare wire end to each of the terminals of the GWMS2 wall switch.

4.Install the wall switch and cover in the wall.

REMOVING/REPLACING GLASS DOOR

You must remove glass door to install op- tional brick liners, logs, lava rock, and em- ber material.

CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For re- placement part information see Replacement Parts, page 33.

1.Remove the upper louver panel by lift- ing upward and out (see Figure 47).

2.Remove the screws from the three tabs at the top of the glass door while hold- ing door securely keeping it from fall- ing forward.

3.Grasp door by both sides and ease it upward off of the lower bracket (see Figure 48).

4.To replace glass door, follow the above instructions in reverse.

Top Louver

Panel

Figure 47 - Removing Top Louver Panel

Screw

Glass

Door

Assembly

Lower Bracket for

Glass Door Assembly

Figure 48 -Removing/ReplacingGlassDoor

22

106394

Image 22
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyNatural GAS Model DVFH34 PROPANE/LP GAS Model DVFH34P Safety Information DVFH34, DVFH34P DIRECT-VENT Fireplace NATURAL/PROPANE/LPLocal Codes Product FeaturesProduct Identification Glossary TermsClearances PRE-INSTALLATION PreparationLocation and Space Requirements Framing and FinishingGeneral Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a ChaseInstallation for Horizontal Termination Terminal into a wall or sidingRigid Vent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Venting with Two 90 Elbow s Vertical Termination ConfigurationsVenting with One 90 Elbow Vertical Rigid Venting Configuration With No Horizontal Run Vertical VentingFMI Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Number DescriptionInstalling GA3700/DA3610TA Blowers Fireplace InstallationInstalling Optional Blower Accessory Check GAS TypeIf your fireplace system is installed Installing GAS Piping to Fireplace Location Installation Items NeededPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyInstallation Items Needed Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Close equipment shutoff valve see Fig- ureInstalling Optional Wall Mounted Thermostat GWMT1 Installing Remote ReceiverInstalling Optional Wall Mount Switch GWMS2 REMOVING/REPLACING Glass DoorInstalling Optional Brick Liner D8037A Installing Rear Brick Panel and Retainer BracketsInstalling LOGS, Lava Rock and Glowing Embers Installing Log NoOperating Fireplace For Your Safety Read Before LightingManual Lighting Procedure Lighting InstructionsThermostat Control Operation Operating Optional GWMS2 Wall Mounted SwitchOptional Remote Operation Ghrc Series OperationInspecting Burners Operating Optional Blower AccessoryPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveService Hints Replacement PartsWiring Diagram Technical ServiceSpecifications DVFH34 DVFH34PIllustrated Parts Breakdown DVFH34 DVFH34P36Parts List DIRECT-VENT Fireplace DVFH34 DVFH34PAccessories Receiver and HAND-HELD Remote Control KIT Ghrc Series DVFH34, DVFH34P DIRECT-VENT Fireplace NATURAL/PROPANE/LP 106394 Warranty Information