OWNER’S MANUAL
VENTING INSTALLATION
Continued
HIGH ALTITUDE
INSTALLATION
Your FMI
When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Re- duce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification.
When installing this fireplace at an eleva- tion above 4500 feet (in Canada), check with local authorities.
Consult your local gas company to help de- termine the proper orifice for your location.
For assistance with any high altitude instal- lation contact DESA International’s Tech- nical Services Department at
PARTS LISTS FOR VENTING KITS AND COMPONENTS
FMI Rigid Venting
Number Description
FD30 30˚ Starter/Adapter (6 5/8" to 7")
6 per box
FD60 60˚ Starter/Adaptor (6 5/8" to 7")
6 per box
F7030 7" to 12" Adjustable pipe length
6 per box
D1031 7" to 12" Adjustable pipe length
1 per box
D3050 Vertical restrictor
6 per box
01806 Basic vertical kit
Adjustable flashing - storm collar, vertical cap
01807 48" Pipe length
6 per box
01808 36" Pipe length
6 per box
01809 24" Pipe length
6 per box
01810 12" Pipe length
6 per box
01811 6" Pipe length
6 per box
01812 17" to 24" adjustable pipe length
6 per box
01813 45˚ Elbow
6 per box
01814 90˚ Elbow
6 per box
01817 Wall firestop
6 per box
01818 Adjustable flashing
6 per box
01819 Steep pitch flashing (12/12
6 per box
01820 Vinyl/Stucco siding standoff
01821 Firestop plate
6 per box
01822 Vertical termination cap
01823 Horizontal round termination
cap
Number Description
01825 36" Snorkel termination
01826 14" Snorkel termination
01827 Termination/high rise/horizontal
01828 Wall strap
6 per box
01829 Storm collar
6 per box
01797 Vertical round high wind termination
01799 Horizontal square high wind termination
106394 | 15 |