Desa DVFH34P installation manual Pressure Testing Fireplace Gas Connections

Page 20

DVFH34, DVFH34P

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

FIREPLACE INSTALLATION

Continued

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Fig- ure 36).

2.Pressurize supply piping system by ei- ther opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace, or using compressed air.

3.Check all joints from propane/LP sup- ply tank or gas meter to equipment shutoff valve (see Figure 37 for pro- pane/LP or Figure 38 for natural). Ap- ply commercial leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Fig- ure 36).

2.Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natu- ral gas fireplace.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Fig- ure 37 for propane/LP or Figure 38 for natural). Apply commercial leak test so- lution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

5.Light fireplace (see Operating Fire- place, pages 25 through 27). Check all other internal joints for leaks.

6.Turn off fireplace (see To Turn Off Gas to Appliance, page 25).

Open

Equipment

Shutoff

Valve

Closed

Figure 36 - Equipment Shutoff Valve

Propane/LP Supply

Tank

Equipment

Shutoff Valve

Gas Valve

Figure 37 - Checking Gas Joints for Propane/LP Gas Fireplace

Equipment

Shutoff Valve

Gas Meter

Gas Valve

Figure 38 - Checking Gas Joints for Natural Gas Fireplace

20

106394

Image 20
Contents Natural GAS Model DVFH34 PROPANE/LP GAS Model DVFH34P For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information DVFH34, DVFH34P DIRECT-VENT Fireplace NATURAL/PROPANE/LPProduct Features Product IdentificationLocal Codes Glossary TermsPRE-INSTALLATION Preparation Location and Space RequirementsClearances Framing and FinishingGeneral Venting Location of Vent TerminationGeneral Venting Venting Installation Installation PrecautionsInstallation Planning Installing Vent System in a ChaseInstallation for Horizontal Termination Terminal into a wall or sidingRigid Vent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVenting with Two 90 Elbow s Vertical Rigid Venting Configuration With No Horizontal Run Vertical VentingHigh Altitude Installation Parts Lists for Venting Kits and ComponentsFMI Rigid Venting Number DescriptionFireplace Installation Installing Optional Blower AccessoryInstalling GA3700/DA3610TA Blowers Check GAS TypeIf your fireplace system is installed Installing GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Close equipment shutoff valve see Fig- ureInstalling Optional Wall Mounted Thermostat GWMT1 Installing Remote ReceiverInstalling Optional Wall Mount Switch GWMS2 REMOVING/REPLACING Glass DoorInstalling Optional Brick Liner D8037A Installing Rear Brick Panel and Retainer BracketsInstalling LOGS, Lava Rock and Glowing Embers Installing Log NoFor Your Safety Read Before Lighting Manual Lighting ProcedureOperating Fireplace Lighting InstructionsOperating Optional GWMS2 Wall Mounted Switch Optional Remote OperationThermostat Control Operation Ghrc Series OperationOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning and Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveReplacement Parts Wiring DiagramService Hints Technical ServiceSpecifications DVFH34 DVFH34PIllustrated Parts Breakdown DVFH34 DVFH34P36Parts List DIRECT-VENT Fireplace DVFH34 DVFH34PAccessories Receiver and HAND-HELD Remote Control KIT Ghrc Series DVFH34, DVFH34P DIRECT-VENT Fireplace NATURAL/PROPANE/LP 106394 Warranty Information