Desa DVFH34P Installing Optional Wall Mounted Thermostat GWMT1, Installing Remote Receiver

Page 21

OWNER’S MANUAL

FIREPLACE INSTALLATION

Continued

INSTALLING OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL - GHRC SERIES/GHRCT SERIES

NOTICE: Use only alkaline bat- teries (not included).

Installing Remote Receiver

1.Open bottom louver and locate the switch bracket on the left.

2.Unscrew the switch bracket. Lean bracket forward so you are able to ac- cess the back of the remote receiver.

3.Locate the battery clip mounted on the back of the receiver. Slide a 9-volt al- kaline battery (not included) through the clip (see Figure 39).

4.Attach the terminal wires to the battery.

5.Remove wire from TH to TPTH on control valve (see Figure 40).

6.Connect wires from receiver to TH and TPTH to control valve (see Figure 41).

7.Replace the switch bracket.

Receiver

Terminal

Wires

Battery Clip

9-Volt Alkaline

Battery

Figure 39 - Attaching Alkaline Battery to Receiver

Figure 40 - Disconnecting TH to TPTH Wire

To

Optional

Remote

Accessory

Figure 41 - Control Valve Terminals

Installing 9-Volt Alkaline Battery

in Hand-Held Remote Control

Unit

1.Remove battery cover on back of re- mote control unit.

2.Attach terminal wires to a 9-volt alka- line battery (not included). Place bat- tery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

Battery

Cover

Terminal

Remote

Wires

Control Unit

9-Volt Alkaline Battery

Battery

Housing

Figure 42 - Installing Alkaline Battery in Hand-Held Remote Control Unit

Remote

Control

Unit

Figure 43 - Installing Battery in Hand-Held

Remote Control Unit (GHRCTA Series

Only)

INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1

WARNING: Installation must be done by a qualified installer familiar with low voltage wiring procedures.

WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.

NOTICE: The GWMT1 includes 25' of wire for installation. Your fire- place includes 15' of wire for ac- cessory installation. Choose the length that best fits your needs when installing this accessory.

1.Open lower louver panel. The valve is attached to the underside of the fire- box assembly.

2.Disconnect the wire that runs from TH to TPTH from the valve as shown in Figure 40.

3.Connect one terminal of the provided wire for the wall thermostat to the TPTH terminal on the valve. Connect remain- ing wire terminal to the TH terminal on the valve. Make sure that the wire termi- nals are in the positions on the unit as pictured in Figure 44. If wires are not connected as shown the thermostat will not work.

To Wall Optional

Remote Accessory

t

Figure 44 - Control Valve Terminals

Continued

106394

21

Image 21
Contents For Your Safety For Your Safety What to do if YOU Smell GASNatural GAS Model DVFH34 PROPANE/LP GAS Model DVFH34P DVFH34, DVFH34P DIRECT-VENT Fireplace NATURAL/PROPANE/LP Safety InformationProduct Identification Product FeaturesLocal Codes Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingLocation of Vent Termination General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseTerminal into a wall or siding Installation for Horizontal TerminationRigid Vent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Vertical Termination Configurations Venting with Two 90 Elbow sVenting with One 90 Elbow Vertical Venting Vertical Rigid Venting Configuration With No Horizontal RunParts Lists for Venting Kits and Components High Altitude InstallationFMI Rigid Venting Number DescriptionInstalling Optional Blower Accessory Fireplace InstallationInstalling GA3700/DA3610TA Blowers Check GAS TypeIf your fireplace system is installed Installation Items Needed Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsClose equipment shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsInstalling Remote Receiver Installing Optional Wall Mounted Thermostat GWMT1REMOVING/REPLACING Glass Door Installing Optional Wall Mount Switch GWMS2Installing Rear Brick Panel and Retainer Brackets Installing Optional Brick Liner D8037AInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsOptional Remote Operation Operating Optional GWMS2 Wall Mounted SwitchThermostat Control Operation Ghrc Series OperationPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementWiring Diagram Replacement PartsService Hints Technical ServiceDVFH34 DVFH34P SpecificationsDVFH34 DVFH34P36 Illustrated Parts BreakdownDIRECT-VENT Fireplace DVFH34 DVFH34P Parts ListAccessories Receiver and HAND-HELD Remote Control KIT Ghrc Series DVFH34, DVFH34P DIRECT-VENT Fireplace NATURAL/PROPANE/LP 106394 Warranty Information