Installation
Continued
WARNING: Never connect natural gas fireplace to private
Installation Items Needed
Before installing fireplace, make sure you have the items listed below.
•external regulator for propane/LP unit only (supplied by installer)
•piping (check local codes)
•sealant (resistant to propane/LP gas)
•equipment shutoff valve *
•test gauge connection *
•sediment trap (optional)
•tee joint
•pipe wrench
•approved flexible gas line with gas connector (if allowed by local codes) (not provided)
*A CSA
For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pres- sure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 14. Pointing the vent down protects it from freezing rain or sleet.
Propane/LP
Supply Tank
External
Regulator
Vent
Pointing
Down
Figure 14 - External Regulator With Vent
Pointing Down
CAUTION: Use only new, black iron or steel pipe. Inter-
Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 15).
IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.
Check your building codes for any special re- quirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves. Never use sealant on flare threads.
CSA
Equipment Shutoff Valve
With 1/8" NPT Tap*
| Natural Gas |
| From Gas Meter |
| (5" W.C.** to 10.5" |
| W.C. Pressure) |
| Propane/LP |
| From External |
| Regulator |
| (11" W.C.** to 14" |
3" Minimum | W.C. Pressure) |
|
Cap Pipe Tee
Nipple Joint
Sediment Trap
Figure 15 - Gas Connection
*Purchase the optional CSA
Accessories, page 31.
** Minimum inlet pressure for purpose of input adjustment.