OPERATING FIREPLACE

 

Continued

 

 

 

Flame Adjustment Knob

REMOTE

 

 

OL

N

 

 

OFF

 

 

O

 

O

ON

T

F

 

 

O

F

HI

 

LIP

 

Selector Switch in Remote

Control Knob

Position (Optional Hand-

in On Position

Held Remote Control)

 

Figure 31 - Setting the Selector Switch, Control Knob and Flame Adjustment Knob for Hand-Held Remote Operation

On/Off Series (Model HRC100)

Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 32).

To Lock press both buttons on hand-held remote control until light stops flashing. Hand- held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.

To Unlock press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.

Control Button Turns

Burners On and Off

Figure 32 - On/Off Hand-Held Remote

Control Unit (HRC100)

Thermostat Series (Model hrc200)

The hand-held remote can be operated using either the manual mode (MANU) or thermo- static mode (AUTO) (see Figure 33). To select Fahrenheit/Centigrade mode display, carefully press the ˚C/˚F mode button with the end of a paper clip or similar blunt object.

Manual Mode

1. Press the POWER and LOCK buttons togeth- er to turn on the hand-held remote control.

2. Press the MANU button to turn on the fireplace.

3. Press the POWER and LOCK buttons together to turn off the fireplace.

 

 

Digital Display Shows

Indicator

 

Temperature and Settings

Light

 

 

 

 

Locks

 

 

 

Turns

 

 

 

Hand-Held

System to

ROOM

SET

 

 

AUTO

Remote On

Prevent

TEMP

TEMP

 

 

 

or Off and

Accidental

 

 

 

 

TEMP

 

Allows You

Ignition

LOCK

POWER

 

 

 

 

 

 

to Choose

Turns

MANU ºC/ºF

AUTO

the Manual

Burners

 

 

 

Setting

On or Off

 

 

 

 

 

 

 

 

Selects

Increases or Decreases

AUTO Mode

 

Room Temperature in

 

°C/°F Mode

AUTO Mode

 

 

 

Button

Figure 33 - Thermostat Hand-Held Remote Control Unit (HRC200)

Auto (Thermostatic) Mode

1. Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2. Press AUTO button to select this mode.

3. Set the desired room temperature by press- ing the TEMP + or - buttons.

4. Press the POWER and LOCK buttons together to turn off the fireplace

Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place the hand-held remote in the center of the room facing towards the fireplace.

Note: Do not hold the hand-held remote for a long time. Body temperature will affect its operation in the AUTO mode.

Safety Features

When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fireplace, the receiver ON/OFF/REMOTE switch should be in the OFF position.

Auto Shutoff Feature

1. If the average room temperature exceeds

82 degrees Fahrenheit (28 degrees Centi- grade), the hand-held remote control will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode.

119305-01A

www.desatech.com

23

Image 23
Contents VSGF36NTB, VSGF36PTB, VSGF36NRB and VSGF36PRB What to do if YOU Smell GASSafety Information Table of ContentsSafety Information Local Codes Unpacking Product FeaturesProduct Identification Planning Product SpecificationsLocating Firebox Confined and Unconfined Space Air For Combustion VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Outdoors InstallationVentilation AIR Ventilation Air From Inside BuildingMinimum Wall and Ceiling Clearances see Installation ClearancesMantel Clearances for Built-In Installation Built-In Firebox InstallationFront Width Depth Rough Opening Dimensions for Built-in InstallationInstalling Gas Piping to Fireplace Location Installing Firebox UsingOptional Accessory Mantels Propane/LP Installation Items NeededNatural Gas Checking Gas Connections, Connecting Fireplace to Gas SupplyTest Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections KPaMiddle Right Log Middle Left Log Installing LogsInstalling Fireplace Hood and Screen Hard-wiring FireboxLighting Instructions For Your Safety Read Before LightingOperating Fireplace Thermostat ModelsTo Turn OFF GAS Manual Lighting ProcedureRemote Control Models Thermostat Control OperationSet flame adjustment knob to any level between HI and LO Remote Operation Blower OperationTo Turn OFF GAS To Appliance Optional Hand-HeldThermostat Series Model hrc200 On/Off Series Model HRC100Main burner Key Pad Lock FeatureInspecting Burners Pilot Flame PatternBurner Injector Holder Pilot Air Inlet Hole Cleaning MaintenanceService Hints Wiring Diagram Replacement PartsSpecifications Technical ServiceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, See Cleaning and Mainte Shut off gas supply Do not try to light any appliance Accessories Models VSGF36PTB, VSGF36NTB Illustrated Parts BreakdownParts List Models VSGF36PRB, VSGF36NRB Parts List Models VSGF36PTB, VSGF36NTB, VSGF36PRB and VSGF36NRB KEY NO. Part no Description 119305-01A 119305-01A Limited Warranty VENT-FREE GAS Fireplace System Warranty InformationKeep this Warranty