SAFETY INFORMATION

Continued

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) in- side any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only).

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This fireplace shall not be installed in a bed- room or bathroom.

5.Do not use this fireplace as a wood-burning fireplace. Use only the logs provided with the fireplace.

6.Do not add extra logs or ornaments such as pine cones, vermiculite or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

7.To prevent the creation of soot, follow the instructions in Cleaning and maintenance, page 25.

8.Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

9.This fireplace needs fresh air ventilation to run properly. This fireplace has an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if enough fresh air is not available. See Air for Combustion and Ventilation, page 7. If fireplace keeps shutting off, see Troubleshooting, page 27.

10.Do not run fireplace

where flammable liquids or vapors are used or stored

under dusty conditions

11.Do not use this fireplace to cook food or burn paper or other objects.

12.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

13.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

14.Turn fireplace off and let cool before servicing. Only a qualified service person should service and repair fireplace.

15.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

16.To prevent performance problems in propane/LP units, do not use propane/LP fuel tanks of less than 100 lbs. capacity (propane/LP units only).

17.Provide adequate clearances around air openings.

Local Codes

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the lat- est edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note: Where listed vented decorative logs are required, thermostat operation is not permitted.

State of Massachusetts: The installa- tion must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

Vent-free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts.

www.desatech.com119305-01A

Image 4
Contents What to do if YOU Smell GAS VSGF36NTB, VSGF36PTB, VSGF36NRB and VSGF36PRBTable of Contents Safety InformationSafety Information Local Codes Product Identification Product FeaturesUnpacking Locating Firebox Product SpecificationsPlanning Air For Combustion Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsInstallation Clearances Minimum Wall and Ceiling Clearances seeBuilt-In Firebox Installation Mantel Clearances for Built-In InstallationRough Opening Dimensions for Built-in Installation Front Width DepthOptional Accessory Mantels Installing Firebox UsingInstalling Gas Piping to Fireplace Location Natural Gas Installation Items NeededPropane/LP Connecting Fireplace to Gas Supply Checking Gas Connections,Pressure Testing Fireplace Gas Connections Checking GAS ConnectionsKPa Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Logs Middle Right Log Middle Left LogHard-wiring Firebox Installing Fireplace Hood and ScreenFor Your Safety Read Before Lighting Operating FireplaceThermostat Models Lighting InstructionsManual Lighting Procedure Remote Control ModelsThermostat Control Operation To Turn OFF GASSet flame adjustment knob to any level between HI and LO Blower Operation To Turn OFF GAS To ApplianceOptional Hand-Held Remote OperationOn/Off Series Model HRC100 Thermostat Series Model hrc200Key Pad Lock Feature Inspecting BurnersPilot Flame Pattern Main burnerCleaning Maintenance Burner Injector Holder Pilot Air Inlet HoleWiring Diagram Replacement Parts SpecificationsTechnical Service Service HintsTroubleshooting Observed Problem Possible Cause RemedyMaintenance, See Cleaning and Mainte Shut off gas supply Do not try to light any appliance Accessories Illustrated Parts Breakdown Models VSGF36PTB, VSGF36NTBParts List Models VSGF36PRB, VSGF36NRB Parts List Models VSGF36PTB, VSGF36NTB, VSGF36PRB and VSGF36NRB KEY NO. Part no Description 119305-01A 119305-01A Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace System