Desa VSGF36PTB Checking GAS Connections, KPa, Test Pressures Equal To or Less Than Psig 3.5 kPa

Page 16

Installation

Continued

CHECKING GAS CONNECTIONS

WARNING: Test all gas pip- ing and connections, internal and external to unit, for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

3.Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP supply to equipment shutoff valve for propane/ LP (see Figures 19 and 20). Apply noncorro- sive leak detection fluid to all joints. Bubbles forming show a leak.

4.Correct all leaks at once.

open flame to check for a leak. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

Equipment Shutoff Valve

Open

Correct all leaks at once.

Closed

Figure 18 - Equipment Shutoff Valve

CAUTION: Make sure exter- nal regulator has been installed between propane/LPsupply and fireplace. See guidelines under Connecting Fireplace to Gas Supply, page 15.

Pressure Testing gas Supply Piping system

Test Pressures In Excess Of 1/2 PSIG

Gas Control Valve

Equipment

Shutoff

Valve

Gas Meter

(3.5 kPa)

1. Disconnect fireplace with its main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage fireplace regulator.

2. Cap off open end of gas pipe where equipment shutoff valve was connected.

3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5. Correct all leaks at once.

6. Reconnect fireplace and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than

1/2 PSIG (3.5 kPa)

1. Close equipment shutoff valve (see Figure 18).

Figure 19 - Checking Gas Joints for

Natural Gas

Equipment Shutoff Valve

Propane/LP

Supply Tank

Gas Control Valve

Figure 20 - Checking Gas Joints for

Propane/LP Gas

Pressure Testing Fireplace Gas

Connections

1. Open equipment shutoff valve (see Figure 18).

2. Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3. Make sure control knob of fireplace is in the OFF position.

16

www.desatech.com

119305-01A

Image 16
Contents What to do if YOU Smell GAS VSGF36NTB, VSGF36PTB, VSGF36NRB and VSGF36PRBTable of Contents Safety InformationSafety Information Local Codes Product Identification Product FeaturesUnpacking Locating Firebox Product SpecificationsPlanning Air For Combustion Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsInstallation Clearances Minimum Wall and Ceiling Clearances seeBuilt-In Firebox Installation Mantel Clearances for Built-In InstallationRough Opening Dimensions for Built-in Installation Front Width DepthOptional Accessory Mantels Installing Firebox UsingInstalling Gas Piping to Fireplace Location Natural Gas Installation Items NeededPropane/LP Connecting Fireplace to Gas Supply Checking Gas Connections,Pressure Testing Fireplace Gas Connections Checking GAS ConnectionsKPa Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Logs Middle Right Log Middle Left LogHard-wiring Firebox Installing Fireplace Hood and ScreenFor Your Safety Read Before Lighting Operating FireplaceThermostat Models Lighting InstructionsManual Lighting Procedure Remote Control ModelsThermostat Control Operation To Turn OFF GASSet flame adjustment knob to any level between HI and LO Blower Operation To Turn OFF GAS To ApplianceOptional Hand-Held Remote OperationOn/Off Series Model HRC100 Thermostat Series Model hrc200Key Pad Lock Feature Inspecting BurnersPilot Flame Pattern Main burnerCleaning Maintenance Burner Injector Holder Pilot Air Inlet HoleWiring Diagram Replacement Parts SpecificationsTechnical Service Service HintsTroubleshooting Observed Problem Possible Cause RemedyMaintenance, See Cleaning and Mainte Shut off gas supply Do not try to light any appliance Accessories Illustrated Parts Breakdown Models VSGF36PTB, VSGF36NTBParts List Models VSGF36PRB, VSGF36NRB Parts List Models VSGF36PTB, VSGF36NTB, VSGF36PRB and VSGF36NRB KEY NO. Part no Description 119305-01A 119305-01A Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace System