Desa VSGF36NRB Wiring Diagram Replacement Parts, Specifications, Technical Service, Service Hints

Page 26

Wiring Diagram

Note: For proper operation of optional accessories, the wires from the thermopile to the control must be connected exactly as shown.

Replacement Parts

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

 

 

 

Thermopile

 

 

 

 

Specifications

Models VSGF36NTB and VSGF36NRB

Rating (Variable)

33,000/21,500 Btu/Hr

Type Gas

Natural Gas

Ignition

Piezo

Pressure Manifold

3.5" W.C.

Inlet Gas Pressure (in. of water)

Maximum 10.5"

 

Minimum*

5"

Shipping Weight

120 lbs.

* For input adjustment

 

Models VSGF36PTB and VSGF36PRB

Rating (Variable)

33,000/21,500 Btu/Hr

Type Gas

Propane/LP

Ignition

Piezo

Pressure Manifold

7.9" W.C.

Inlet Gas Pressure (in. of water)

Maximum 13"

Minimum*

11"

• Shipping Weight

120 lbs.

* For input adjustment

 

Parts Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products’ Technical Service Department at 1-866-672-6040.

When calling DESA, have ready

your name

your address

model and serial numbers of your firebox

how firebox was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products at 1-866-672-6040 for referral information.

When calling DESA Heating Products, have ready

model number of your firebox

the replacement part number

Note: The firebox identification label (including model number, serial number, clearances, etc.) is located on the right front edge of the firebox.

Technical Service

You may have further questions about installation, operation or troubleshooting. If so, contact DESA Heating Products’Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your firebox ready.

You can also visit DESA Heating Products’techni- cal services web site at www.desatech.com.

Service Hints

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

• propane/LP gas supply may be low for propane/ LP unit

You may feel your gas pressure is too low. If so, contact your local gas supplier.

26

www.desatech.com

119305-01A

Image 26
Contents What to do if YOU Smell GAS VSGF36NTB, VSGF36PTB, VSGF36NRB and VSGF36PRBTable of Contents Safety InformationSafety Information Local Codes Unpacking Product FeaturesProduct Identification Planning Product SpecificationsLocating Firebox Unusually Tight Construction Air For Combustion VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsInstallation Clearances Minimum Wall and Ceiling Clearances seeBuilt-In Firebox Installation Mantel Clearances for Built-In InstallationRough Opening Dimensions for Built-in Installation Front Width DepthInstalling Gas Piping to Fireplace Location Installing Firebox UsingOptional Accessory Mantels Propane/LP Installation Items NeededNatural Gas Connecting Fireplace to Gas Supply Checking Gas Connections,KPa Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Logs Middle Right Log Middle Left LogHard-wiring Firebox Installing Fireplace Hood and ScreenThermostat Models For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsThermostat Control Operation Manual Lighting ProcedureRemote Control Models To Turn OFF GASSet flame adjustment knob to any level between HI and LO Optional Hand-Held Blower OperationTo Turn OFF GAS To Appliance Remote OperationOn/Off Series Model HRC100 Thermostat Series Model hrc200Pilot Flame Pattern Key Pad Lock FeatureInspecting Burners Main burnerCleaning Maintenance Burner Injector Holder Pilot Air Inlet HoleTechnical Service Wiring Diagram Replacement PartsSpecifications Service HintsTroubleshooting Observed Problem Possible Cause RemedyMaintenance, See Cleaning and Mainte Shut off gas supply Do not try to light any appliance Accessories Illustrated Parts Breakdown Models VSGF36PTB, VSGF36NTBParts List Models VSGF36PRB, VSGF36NRB Parts List Models VSGF36PTB, VSGF36NTB, VSGF36PRB and VSGF36NRB KEY NO. Part no Description 119305-01A 119305-01A Limited Warranty VENT-FREE GAS Fireplace System Warranty InformationKeep this Warranty