Vermont Casting DVT44 installation instructions Sidewall Applications

Page 14

Chateau™

Vertical Run (in feet) (Measured from the appliance flue collar to the top of the vent pipe.)

May use one (1) elbow only

��

 

��

 

��

 

��

 

��

 

��

 

��

 

��

 

��

 

��

 

��

 

��

 

��

 

��

 

��

May use up to

��

three (3) 90°

elbows, but must

 

��not have two (2)

��consecutive 90°

��elbows in horizon-

��tal plane

��

 

��

 

��

 

��

 

��

 

��

 

��

 

��

 

��

 

��

 

 

 

 

 

 

���

 

���

Unacceptable vent-

 

ing configuration

 

 

� �

� � � � � � � �� �� �� �� �� �� �� �� �� �� ��

Minimum clearance between vent pipes and combustible materials is 3¹⁄” (89 mm) on top, 2¹⁄” (64 mm) on both sides and 1¹⁄” (38 mm) on the bottom.

When the vent termination exits through foundations less than 20” (508 mm) below siding outcrop, the vent pipe must be flush with the siding.

It is always best to locate the fireplace in such a way that minimizes the number of offsets and horizontal vent length of vent pipe from the flue collar of the fire- place to the face of the outer wall.

Horizontal plane means no vertical rise exists on this portion of the vent assembly.

 

20’ (6 m)

 

 

Unitized Elbow

 

 

 

(SK890)

 

 

 

 

 

Pipe

 

 

 

Straps

(4.3m)

 

 

Every 3’

Pipe Straps

(914 mm)

 

Every 3’ (914

 

14’

 

mm)

Firestop/Zero

 

 

Clearance Sleeve

 

Minimum 2’ (610

 

 

mm) Section

 

 

NOTE: Apply high temperature sealant or UL approved high temperature metal adhesive tape as directed on Page

12.

FP1012a

Fig. 16 Support straps for horizontal runs.

The maximum number of 90° elbows per side wall

installation is three (3), but must not have two (2)

consecutive elbows in the horizontal plane.

Horizontal Run (in feet)

FP1359

Fig. 15 Horizontal vent termination window.

Sidewall Applications

Since it is very important that the vent- ing system maintain its balance between

the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to.

NOTE: The penetration to the outside of the build- ing or structure shall be sealed air and weather tight.

Use of the Restrictor Plates in

Horizontal Venting Applications

The primary purpose for the vent restrictor plate is to regain flame height under certain venting conditions as outlined below.

The DVT38 is shipped with the fresh air plate settings at #4 (this applies to both natural gas and propane) when using the horizontal starter vent kit SK8DVSK.

A minimum of 2’ (610 mm) vertical section off the top

of the unit is required, an elbow and a 1’ (305 mm)

maximum horizontal run to get through a wall. (Fig.

17)

2'

(610mm)

C Wall Opening

L

2'

(610mm)

X

(DVT44) X = 7’3¹⁄” (2216 mm)

(DVT38) X = 6’9⁷⁄” (2080 mm)

FP1237a

Fig. 17 Minimum vertical run / maximum horizontal run.

14

20011956

Image 14
Contents INSTALLER/CONSUMER Safety Information What to do if YOU Smell GASTable of Contents Installation & Operating Instructions Please Review the Following CarefullyFireplace Dimensions DVT38 Mantels Locating Your FireplaceClearance to Combustibles Final Finishing HearthFraming and Finishing Gas Inlet and Manifold Pressures Gas Line InstallationGas Specifications High ElevationsControl System Control System InstallationElectrical Junction Box Special Feature for Cold Climates Connect 120V AC electrical supplyGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationDVT38N DVT38P DVT44N DVT44P Quick Reference for Fresh Air Restrictor Plate / Flue BaffleApplication General Information Assembling Vent Pipes SK8 Venting Pipes Canadian InstallationsUSA Installations Horizontal TerminationSidewall Applications Use of the Restrictor Plates Horizontal Venting ApplicationsSidewall Installation StepAlways install horizontal venting on a level plane Vertical height requirementFresh Air Restrictor Plate Vertical Through-the-Roof Installation Typical offset applicationMin 610mm Chimney Components Component Description Model NumberRestrictor Plate Installation Glass Frame Assembly RemovalGlass Cleaning Operating InstructionsCeramic Refractory Installation Appliance Kit Model DescriptionLog, Lava Rock and Ember Placement DVT38 LogsPosition the Log Grate Burner. Remove the two Mandatory for proper carry over of flame into the burner tubePosition the Log Rear Left Position the Log Front Middle Right DVT38 logset complete Flame Characteristics Correct pilot flame appearanceTrim Installation Trim frame in placeTurning Off the Gas to the Appliance Lighting & Operating InstructionsLighting Instructions Troubleshooting Igniter operationTroubleshooting American Flame Gas Control System Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Converting the Gas Control Valve Check Manifold PressureInjector Orifice Size Matrix Air Shutter SettingsPilot Flame Adjustment Valve Minimum Rate ScrewBurner and Burner Compartment MaintenanceCleaning the Control System DVT38, DVT44 DVT38 DVT44 Colonial Red Limestone HerringboneFuel Conversion Kits Ceramic Refractory Kits AccessoriesBack-up Battery Kit Chateau Chateau Limited Lifetime Warranty Product Covered by this WarrantyEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %