Vermont Casting DVT44 installation instructions Position the Log Rear Left

Page 25
Figure 45

7.Position the Log Grate Right and Left. Position the right and left grate logs simultaneously on the grate in front of the burner housing by hold- ing the two logs with the narrower end toward the middle and the bark details toward the front. Set the logs and lean forward toward the grate. The outer end of the logs should line up with the grate on the outside. (Fig. 43)

8.Position the Log Rear Right . Posi- tion the log rear right by holding the log at an angle with the pointed end down toward the bottom. Set the

Figure 43

Log Grate Left

Chateau™

Log Grate Right

LG402

Figure 44

Log Rear

Log Rear Right

Left

 

pointed end on the matching notch on the overlay toward the right. Rest the wide end toward the back right. The log rests in place by touching the rear refractory lower on the right. (Fig. 44)

9.Position the Log Rear Left

. Position the log rear left by holding the log at an able with the pointed end down toward the bottom. Set the pointed end on the matching notch on the overlay toward the left. Rest the wide end toward the back left. The log rests in place by touching the rear

10. Position the Log Front Left. Posi- tion the log front left by holding the log

with the wide end toward the front and the nar- row end toward the back. Set the rectangular indentation located on the bottom of this log over the rectangular protrusion on the far left end of the log grate left. Lay the pointed end of the log over the burner overlay outside

the log rear left. (Fig. 45)

11.Position the Log Front Middle Left. Position the log front middle left by holding the log with the wide end toward the front and the narrow end toward the back. Set the round indentation located on the bottom of this log over the round protrusion

on the rear left log. Set the log over the fettle where the V-shaped end on the front

of this log (split area) comes in contact with the second left tine on the fettle. (Fig. 45)

Log Front Left

Log Front

Middle Left

LG405

refractory lower on the left.

(Fig. 44)

 

 

Log Front Right

LG404

Log Front Middle

Right (DVT44)

20011956

25

Image 25
Contents What to do if YOU Smell GAS INSTALLER/CONSUMER Safety InformationTable of Contents Please Review the Following Carefully Installation & Operating InstructionsFireplace Dimensions DVT38 Clearance to Combustibles Locating Your FireplaceMantels Framing and Finishing HearthFinal Finishing Gas Specifications Gas Line InstallationGas Inlet and Manifold Pressures High ElevationsElectrical Junction Box Control System InstallationControl System Connect 120V AC electrical supply Special Feature for Cold ClimatesLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2Application Quick Reference for Fresh Air Restrictor Plate / Flue BaffleDVT38N DVT38P DVT44N DVT44P USA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Horizontal TerminationUse of the Restrictor Plates Horizontal Venting Applications Sidewall ApplicationsStep Sidewall InstallationVertical height requirement Always install horizontal venting on a level planeFresh Air Restrictor Plate Typical offset application Vertical Through-the-Roof InstallationMin 610mm Component Description Model Number Chimney ComponentsGlass Cleaning Glass Frame Assembly RemovalRestrictor Plate Installation Operating InstructionsAppliance Kit Model Description Ceramic Refractory InstallationDVT38 Logs Log, Lava Rock and Ember PlacementMandatory for proper carry over of flame into the burner tube Position the Log Grate Burner. Remove the twoPosition the Log Rear Left Position the Log Front Middle Right DVT38 logset complete Correct pilot flame appearance Flame CharacteristicsTrim frame in place Trim InstallationLighting Instructions Lighting & Operating InstructionsTurning Off the Gas to the Appliance Igniter operation TroubleshootingTroubleshooting American Flame Gas Control System Conversion Procedure Conversion PrecautionsFuel Conversion Instructions Check Manifold Pressure Converting the Gas Control ValvePilot Flame Adjustment Air Shutter SettingsInjector Orifice Size Matrix Valve Minimum Rate ScrewCleaning the Control System MaintenanceBurner and Burner Compartment DVT38, DVT44 Colonial Red Limestone Herringbone DVT38 DVT44Fuel Conversion Kits Back-up Battery Kit AccessoriesCeramic Refractory Kits Chateau Chateau Product Covered by this Warranty Limited Lifetime WarrantyModel EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings