Vermont Casting DVT44 Injector Orifice Size Matrix, Air Shutter Settings, Valve Minimum Rate Screw

Page 35

Chateau™

 

 

 

Table 1

Injector Orifice Size Matrix

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conversion to LP

 

 

 

 

 

 

 

 

 

Burner Orifice

 

 

Input (BTU/hr)

Kit #

Model

Front

Part #

 

Middle

Part #

Rear

Part #

Minimum

Maximum

20011992

DVT38IP

#66

20009182

 

#59

20000664

#50

30000337

34,000

46,000

 

 

(.033”)

 

 

(.041”)

 

(.070”)

 

 

 

20012367

DVT44IP

#63

20006251

 

#57

20004587

#49

20006252

45,000

60,000

 

 

(.037”)

 

 

(.043”)

 

(.073”)

 

 

 

Table 2 Air Shutter Settings

Conversion to LP

 

Burner Tube

Burner Housing

Model

Air Shutter Setting

Air Shutter Setting

DVT38IP

Fully open

n/a

DVT44IP

Fully open

Fully open

Table 3 Valve Minimum Rate Screw

Model

Size

Part #

DVT38IP

#31 (.120”)

20012364

DVT44IP

No Shank Screw

20012264

Pilot Flame Adjustment

Typically, the top 3/8” or 1/2” of the pilot flame sensor should be engulfed in the pilot flame. (Page 28, Fig. 50)

To adjust pilot burner:

1.Locate pilot adjustment screw on the valve next to the black plastic cap. Refer to Page 30.

2.Adjust pilot screw to provide proper sized flame. Only a small adjustment should be needed.

NOTE: Do not rotate screw excessively. Do not adjust any other screws on the valve.

20011956

35

Image 35
Contents What to do if YOU Smell GAS INSTALLER/CONSUMER Safety InformationTable of Contents Please Review the Following Carefully Installation & Operating InstructionsFireplace Dimensions DVT38 Mantels Locating Your FireplaceClearance to Combustibles Final Finishing HearthFraming and Finishing High Elevations Gas Line InstallationGas Specifications Gas Inlet and Manifold PressuresControl System Control System InstallationElectrical Junction Box Connect 120V AC electrical supply Special Feature for Cold ClimatesLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2DVT38N DVT38P DVT44N DVT44P Quick Reference for Fresh Air Restrictor Plate / Flue BaffleApplication Horizontal Termination Canadian InstallationsUSA Installations General Information Assembling Vent Pipes SK8 Venting PipesUse of the Restrictor Plates Horizontal Venting Applications Sidewall ApplicationsStep Sidewall InstallationVertical height requirement Always install horizontal venting on a level planeFresh Air Restrictor Plate Typical offset application Vertical Through-the-Roof InstallationMin 610mm Component Description Model Number Chimney ComponentsOperating Instructions Glass Frame Assembly RemovalGlass Cleaning Restrictor Plate InstallationAppliance Kit Model Description Ceramic Refractory InstallationDVT38 Logs Log, Lava Rock and Ember PlacementMandatory for proper carry over of flame into the burner tube Position the Log Grate Burner. Remove the twoPosition the Log Rear Left Position the Log Front Middle Right DVT38 logset complete Correct pilot flame appearance Flame CharacteristicsTrim frame in place Trim InstallationTurning Off the Gas to the Appliance Lighting & Operating InstructionsLighting Instructions Igniter operation TroubleshootingTroubleshooting American Flame Gas Control System Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Check Manifold Pressure Converting the Gas Control ValveValve Minimum Rate Screw Air Shutter SettingsPilot Flame Adjustment Injector Orifice Size MatrixBurner and Burner Compartment MaintenanceCleaning the Control System DVT38, DVT44 Colonial Red Limestone Herringbone DVT38 DVT44Fuel Conversion Kits Ceramic Refractory Kits AccessoriesBack-up Battery Kit Chateau Chateau Product Covered by this Warranty Limited Lifetime WarrantyModel EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings