Vermont Casting DVT44 Quick Reference for Fresh Air Restrictor Plate / Flue Baffle, Application

Page 12

Chateau™

Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.

Inside Corner

Outside Corner

Alcove Applications*

 

 

 

F =

 

 

G =

 

Combustible

G

Combustible

 

6"

(152 mm)

 

6" (152 mm)

V

Noncombustible

 

 

2"

(51 mm)

 

Noncombustible

 

V

 

F

 

2" (51 mm)

 

 

Balcony -

Balcony -

with no side wall

with perpendicular side wall

M

M

 

V

V

 

P

M =

Combustible &

Noncombustible

Combustible &

M = 24" (610 mm)

Noncombustible

P = 20” (508 mm)

12" (305 mm)

D

C C

V

E

O

E = Min. 6” (152 mm) for non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls

O = 8’ (2.4 m) Min.

No.

 

 

of Caps

DMin.

CMax.

1

3’ (914 mm)

2 x DActual

2

6’ (1.8 m)

1 x DActual

3

9’ (2.7 m)

2/3 x DActual

4

12’ (3.7 m)

1/2 x DActual

DMin. = # of Termination caps x 3

CMax. = (2 / # termination caps) x DActual

584-15

*NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3’ (914 mm) minimum between termination caps. 2. All mechanical air intakes within 10’ (1 m) of a termination cap must be a minimum of 3’ (914 mm) below the termination cap. 3. All gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap.

Fig. 13 Termination clearances.

Quick Reference for Fresh Air Restrictor Plate / Flue Baffle

Application

Item

DVT38N

DVT38P

DVT44N

DVT44P

SK8DVSK

Flue Restrictor Plate

3”

None

None

4¹⁄

 

Fresh Air Restrictor Plate

None

None

None

#1

Vertical Less than 12’

Flue Restrictor Plate

None

None

None

None

 

Fresh Air Restrictor Plate

None

None

None

None

Vertical 12’ to 20’

Flue Restrictor Plate

4¹⁄

4¹⁄

4¹⁄

4¹⁄

 

Fresh Air Restrictor Plate

#3

#3

#3

#3

Vertical 20’ to 30’

Flue Restrictor Plate

4¹⁄

4¹⁄

4¹⁄

4¹⁄

 

Fresh Air Restrictor Plate

#2

#2

#2

#2

Vertical 30’ to 40’

Flue Restrictor Plate

4¹⁄

4¹⁄

4¹⁄” or 6³⁄

4¹⁄” or 6³⁄

 

Fresh Air Restrictor Plate

#1

#1

#1

#1

NOTE: Refer to Page 22, Figure 35 for instructions to fabricate 3” and 4¹⁄” flue restrictor plates.

12

20011956

Image 12
Contents INSTALLER/CONSUMER Safety Information What to do if YOU Smell GASTable of Contents Installation & Operating Instructions Please Review the Following CarefullyFireplace Dimensions DVT38 Locating Your Fireplace Clearance to CombustiblesMantels Hearth Framing and FinishingFinal Finishing Gas Line Installation Gas SpecificationsGas Inlet and Manifold Pressures High ElevationsControl System Installation Electrical Junction BoxControl System Special Feature for Cold Climates Connect 120V AC electrical supplyGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationQuick Reference for Fresh Air Restrictor Plate / Flue Baffle ApplicationDVT38N DVT38P DVT44N DVT44P Canadian Installations USA InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Horizontal TerminationSidewall Applications Use of the Restrictor Plates Horizontal Venting ApplicationsSidewall Installation StepAlways install horizontal venting on a level plane Vertical height requirementFresh Air Restrictor Plate Vertical Through-the-Roof Installation Typical offset applicationMin 610mm Chimney Components Component Description Model NumberGlass Frame Assembly Removal Glass CleaningRestrictor Plate Installation Operating InstructionsCeramic Refractory Installation Appliance Kit Model DescriptionLog, Lava Rock and Ember Placement DVT38 LogsPosition the Log Grate Burner. Remove the two Mandatory for proper carry over of flame into the burner tubePosition the Log Rear Left Position the Log Front Middle Right DVT38 logset complete Flame Characteristics Correct pilot flame appearanceTrim Installation Trim frame in placeLighting & Operating Instructions Lighting InstructionsTurning Off the Gas to the Appliance Troubleshooting Igniter operationTroubleshooting American Flame Gas Control System Conversion Precautions Conversion ProcedureFuel Conversion Instructions Converting the Gas Control Valve Check Manifold PressureAir Shutter Settings Pilot Flame AdjustmentInjector Orifice Size Matrix Valve Minimum Rate ScrewMaintenance Cleaning the Control SystemBurner and Burner Compartment DVT38, DVT44 DVT38 DVT44 Colonial Red Limestone HerringboneFuel Conversion Kits Accessories Back-up Battery KitCeramic Refractory Kits Chateau Chateau Limited Lifetime Warranty Product Covered by this WarrantyEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %