FREESTANDING INSTALLATION . . . continued

THROUGH THE WALL, DIRECT INSTALLATION. (Figure 16)

1.Select the location for your stove, design the exhaust system and determine the brand and size of "PL" vent to be used.

2.Position the floor pad, (C).

3.Following the "PL" vent manufacturer's specifications, mark and cut a hole through the wall to accommodate the wall thimble, (A), and the outside air pipe, (B), if outside air is to be used. Install the wall thimble, (A). Be sure to run a bead of silicone around the outside edges of the wall thimble to reduce drafts. Insert the proper size of "PL" vent, (D), through the wall thimble, (A). Place your stove on the floor pad, (C), close to its final position. Leave room to connect the "PL" vent to your stove. Place a bead of RTV silicone around the end of your stove's exhaust pipe, (E). Connect the “PL” vent pipe adaptor (J) onto the stoves exhaust pipe. Connect the length of "PL" vent, (D), that is in the thimble, (A), onto the pipe adaptor (E). Fasten together with at least three sheet metal screws (approx. ½” in length). Place a bead of RTV silicone around the connection. Place your stove in its final position on the pad. Place another bead of RTV silicone around the “PL” vent and the inside of the wall thimble, to stop cold air drafts.

4.Note: If 4" PL vent is required, use an increaser, (J), on the stove exhaust pipe.

5.On the outside of the building, place a 45 degree "PL" type elbow, (F), onto the end of the horizontal "PL" vent,

(D). Optionally, place a rodent screen cap, (G), (may be required in some locals), on the end of the elbow, (F). Secure all connections using 3 sheet metal screws and run a bead of RTV silicone around all connections. Also run a bead of RTV silicone around the “PL” vent pipe and the outside of the wall thimble.

6.If outside air is used, install the outside air pipe, (B). Seal the outside air pipe, (B), to your stove's outside air pipe, (I), with RTV silicone. Make sure the outside air pipe fits over, (not inside), your stove's outside air pipe. Install a wind shield (H). Run a bead of silicone around the inside and outside walls, again to reduce cold drafts.

12”

1”

1”

10”

2”

6”

6”

A

PL Wall Thimble

 

 

 

B

Outside Air Intake

 

 

 

C

Hearth Pad

 

 

 

D

PL Vent Length

 

EJ A

A D F

E

Stove Exhaust

 

F

PL 45 deg elbow

 

 

 

G

PL Screened End Cap

 

 

 

H

Fresh Air Hood

4

 

B H G

I

Combustion Air Intake

 

 

 

 

J

PL Pipe Adaptor

 

 

 

Figure 16

C

 

NOTE: Some horizontal, through the wall installations may require a Clean-Out Tee and a minimum 3’ vertical rise of pipe outside the building to help draft the stove. This is required if a proper burn cannot be maintained, after the stove has been tested and the airflow set. This is due to backpressure in the exhaust, caused by the airflow around the house.

Canadian Comfort Industries V04

15

PELPRO OWNERS MANUAL

Copyright 2004

www.pelprostoves.com

Dansons Group Inc.

Image 15
Contents 866 456 Copyright Notice Updates and RegistrationTable of Contents Safety Precautions Safety Precautions Specifications F140 FAN Limit Switch Automatic Safety FeaturesL250 High Limit Switch L120 LOW Limit SwitchInstallation Options Installation Options IncludeFPP Installation Check List For your stoveCCI -AcuTron Board Cutaway View Maximum Venting Size Vent InstallationExhaust Systems General Pellet Vent TypeVent Termination Clearances Pellet Vent Termination Figures 7Foot Package PART# ACFAKT3 Foot Package PART# ACFAKT10 Outside air is Required on ALL Mobile Home InstallationsOutside AIR Through The Wall Kits IncludeFloor Protection Requirements Freestanding Stove InstallationStove Placement Clearances Straight InstallationAlcove Through the Wall Alcove InstallationEJ a Through the WALL, Direct INSTALLATION. FigureCOMMON, but not inclusive, Vertical Installation Designs are Vertical Installations Figures 17Mobile Home Installation Fireplace Insert Installation Installing SOLID-FUEL Inserts Into Factory Built FireplacesVenting Into AN Existing Chimney Full Chimney Reline Fireplace Insert Installation …BUILT-IN Insert Installation BUILT-IN Insert Installation . . . CON’T HOW Your Pelpro Stove Works Operating Your StoveLighting Your Stove Lighting stove manually No Igniter NON-Thermostat ModeBasic Overview Initial Start or SET-UP Manual or NON-THERMOSTAT ModeRE-START Manual or NON-THERMOSTAT Mode ControlsAuger Cycle Trim Pots Fine Tune Adjustments- Factory SettingsShutting the Stove OFF Controls …AIR Inlet Damper Performance Enhancement TipsOperation High / LOW Cycle Option Flashing 3On / OFF Option Flashing 1 Start Initial Appliance Burn SetupPellet Consumption Fine Tuning the Pellet Feed RatesPellet Fuel Pellet QualityASH and Clinkers … FinesPFI Pellet Standards INSERTING, Removing & Adjusting the Burn Grate Cleaning Your EZ-CLEAN GrateMAY Result Required Routine CleaningEvery 2 -3 Days / Weekly Heat Tubes Cold Stove onlySoot FLY ASH Periodic MaintenancePeriodic Maintenance … Trouble Shooting Problem SolutionCheck with Dansons Customer Service Extended Warranty Limited WarrantyAppendix a Optional AccessoriesReplacement Parts Agshtls AgshtsgAgshtss AgshtlgZIP/PC Service & Maintenance Log

IPP Bay View Insert / Built-In, FPP, IPP, FPP Freestanding, IPP, FPP specifications

Dansons Group is renowned for its innovative approach to outdoor and indoor heating solutions, especially with their FPP Freestanding and IPP Bay View Insert/Built-In models. These products are designed to cater to the diverse needs of homeowners seeking both functionality and aesthetics in their heating appliances.

The FPP Freestanding model is a perfect blend of traditional charm and modern technology. It serves as an impressive centerpiece in any setting, providing warmth and ambiance to any space. One of its standout features is its large viewing area, which allows for an unobstructed view of the flames, creating a cozy and inviting atmosphere. It is equipped with advanced combustion technology that ensures efficient burning, maximizing heat output while minimizing emissions. This model is also designed to accommodate a range of fuel options, including wood and pellets, giving users the flexibility to choose what works best for them.

On the other hand, the IPP Bay View Insert/Built-In model offers a seamless integration into existing fireplaces or as a built-in feature in new constructions. This model emphasizes both performance and aesthetics, providing a sleek finish that enhances any room's decor. One of the key technologies in the IPP is its advanced blowers and distribution system, which efficiently circulates heat throughout the space, ensuring even warmth without hot spots. Additionally, the IPP incorporates a unique air-wash system that keeps the glass clean, allowing for a clear view of the flickering flames.

Both the FPP and IPP series prioritize ease of use and maintenance. They are designed with user-friendly controls that allow for easy operation and customization of heat settings. Moreover, Dansons Group emphasizes safety, incorporating features such as automatic shut-off mechanisms and cool-touch exteriors to prevent accidental burns.

In summary, the Dansons Group FPP Freestanding and IPP Bay View Insert/Built-In models stand out for their combination of aesthetic appeal, technological advancement, and user-friendly features. Whether you're looking for a statement piece or a practical heating solution, these products are designed to create a warm ambiance while ensuring efficiency and safety.