MOBILE HOME INSTALLATION

CAUTION: DO NOT INSTALL STOVE IN SLEEPING ROOM

THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR,

CEILING/ROOF MUST BE MAINTAINED!

Your PELPRO stove has been tested and listed for mobile home installation. It may be installed in a mobile home as a "Free Standing Stove", a "Hearth Stove", or as an "In Insert" installed in an existing wood or coal- burning fireplace or as an "Built –In Insert" installed with a mantel.

In addition to all previously detailed installation requirements, mobile home installations must meet the following requirements:

Permanently bolt your stove to the floor, (A). Figure 23, 24

Electrically ground your stove or the pedestal to the steel frame of the home. Use a number 8 gauge copper wire, (B) figure 24, or equivalent.

The stove must have a permanent outside air source with a ¼ inch screen over the inlet. Figure 23, (B,C, D)

For transportation all chimney / vent above the mobile home must be removed.

“PL” Vent must be 3” or 4” PL Vent and must extend a minimum or 36” above the roofline of the mobile home and must be installed using a UL/ULC listed ceiling fire stop (J), figure 23, and rain cap (L), figure 23.

INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.

 

A

Floor Pad

L

B

Combustion Air Intake

K

C

Fresh Air Duct

D

Fresh Air Hood

 

E

Stove Exhaust

 

F

Pipe Adapter

 

G

Clean Out Tee

 

H

Tee Support Bracket

J

I

Pipe

 

J

Firestop Spacer / Ceiling Support

 

K

Roof Flashing / Storm Collar

 

L

Rain Cap

I

 

 

 

H

 

 

 

 

G

 

 

 

 

HEARTH PAD

 

A

BOLT(S)

 

FLOOR

 

 

 

 

 

B

C D

 

FRAME

 

 

B

GROUND

 

A

 

WIRE

 

Figure 24

 

 

 

Figure 23

 

 

 

Note: When moving your Mobile Home, all exterior venting must be removed while Mobile Home is being relocated. Upon completion of relocation all venting must be reinstalled and securely fastened.

Canadian Comfort Industries V04

17

PELPRO OWNERS MANUAL

Copyright 2004

www.pelprostoves.com

Dansons Group Inc.

Image 17
Contents 866 456 Copyright Notice Updates and RegistrationTable of Contents Safety Precautions Safety Precautions Specifications L250 High Limit Switch Automatic Safety FeaturesL120 LOW Limit Switch F140 FAN Limit SwitchFPP Installation OptionsInstallation Options Include CCI -AcuTron Board Cutaway View Installation Check ListFor your stove Exhaust Systems General Vent InstallationPellet Vent Type Maximum Venting SizeVent Termination Clearances Pellet Vent Termination Figures 7Outside AIR Outside air is Required on ALL Mobile Home InstallationsThrough The Wall Kits Include Foot Package PART# ACFAKT3 Foot Package PART# ACFAKT10Stove Placement Freestanding Stove InstallationClearances Straight Installation Floor Protection RequirementsAlcove Through the Wall Alcove InstallationEJ a Through the WALL, Direct INSTALLATION. FigureCOMMON, but not inclusive, Vertical Installation Designs are Vertical Installations Figures 17Mobile Home Installation Venting Into AN Existing Chimney Fireplace Insert InstallationInstalling SOLID-FUEL Inserts Into Factory Built Fireplaces Full Chimney Reline Fireplace Insert Installation …BUILT-IN Insert Installation BUILT-IN Insert Installation . . . CON’T HOW Your Pelpro Stove Works Operating Your StoveLighting Your Stove Lighting stove manually No Igniter NON-Thermostat ModeRE-START Manual or NON-THERMOSTAT Mode Initial Start or SET-UP Manual or NON-THERMOSTAT ModeControls Basic OverviewShutting the Stove OFF Trim Pots Fine Tune Adjustments- Factory SettingsControls … Auger CycleAIR Inlet Damper Performance Enhancement TipsOn / OFF Option Flashing 1 OperationHigh / LOW Cycle Option Flashing 3 Start Initial Appliance Burn SetupPellet Fuel Fine Tuning the Pellet Feed RatesPellet Quality Pellet ConsumptionPFI Pellet Standards ASH and Clinkers …Fines INSERTING, Removing & Adjusting the Burn Grate Cleaning Your EZ-CLEAN GrateEvery 2 -3 Days / Weekly Required Routine CleaningHeat Tubes Cold Stove only MAY ResultSoot FLY ASH Periodic MaintenancePeriodic Maintenance … Check with Dansons Customer Service Trouble ShootingProblem Solution Extended Warranty Limited WarrantyAppendix a Optional AccessoriesReplacement Parts Agshtss AgshtsgAgshtlg AgshtlsZIP/PC Service & Maintenance Log

IPP Bay View Insert / Built-In, FPP, IPP, FPP Freestanding, IPP, FPP specifications

Dansons Group is renowned for its innovative approach to outdoor and indoor heating solutions, especially with their FPP Freestanding and IPP Bay View Insert/Built-In models. These products are designed to cater to the diverse needs of homeowners seeking both functionality and aesthetics in their heating appliances.

The FPP Freestanding model is a perfect blend of traditional charm and modern technology. It serves as an impressive centerpiece in any setting, providing warmth and ambiance to any space. One of its standout features is its large viewing area, which allows for an unobstructed view of the flames, creating a cozy and inviting atmosphere. It is equipped with advanced combustion technology that ensures efficient burning, maximizing heat output while minimizing emissions. This model is also designed to accommodate a range of fuel options, including wood and pellets, giving users the flexibility to choose what works best for them.

On the other hand, the IPP Bay View Insert/Built-In model offers a seamless integration into existing fireplaces or as a built-in feature in new constructions. This model emphasizes both performance and aesthetics, providing a sleek finish that enhances any room's decor. One of the key technologies in the IPP is its advanced blowers and distribution system, which efficiently circulates heat throughout the space, ensuring even warmth without hot spots. Additionally, the IPP incorporates a unique air-wash system that keeps the glass clean, allowing for a clear view of the flickering flames.

Both the FPP and IPP series prioritize ease of use and maintenance. They are designed with user-friendly controls that allow for easy operation and customization of heat settings. Moreover, Dansons Group emphasizes safety, incorporating features such as automatic shut-off mechanisms and cool-touch exteriors to prevent accidental burns.

In summary, the Dansons Group FPP Freestanding and IPP Bay View Insert/Built-In models stand out for their combination of aesthetic appeal, technological advancement, and user-friendly features. Whether you're looking for a statement piece or a practical heating solution, these products are designed to create a warm ambiance while ensuring efficiency and safety.