FIREPLACE INSERT INSTALLATION CONTINUED

When installing into a masonry chimney, it is recommended that the exhaust vent be extended to the top of the chimney as shown to the lower right. However, if the vent pipe does not extend to the top of the chimney, the pipe must extend a minimum of 18” above the damper.

You must seal the damper area with a steel plate when using the direct connection method.

The Vent Pipe Must Extend Above The Damper into the first tile of the flue liner (Figure 25) in the USA and to the top of the chimney CANADA (Figure 26). The chimney must not be corroded or damaged in any way for this type of installation to be permitted. A direct vent may be made through the chimney structure if local codes permit.

DIRECT CONNECTION

Note: This installation not allowed in Canada

8”

18” min.

 

length

 

Metal

18”

Sealing Plate

 

6”

FULL CHIMNEY RELINE

Note: This installation is recommended for all chimney installations!

Deluxe Cap

Liner Support

8”

18”

Optional

Metal Plate

6”

Figure 25

 

Figure 26

Canadian Comfort Industries V04

19

PELPRO OWNERS MANUAL

Copyright 2004

www.pelprostoves.com

Dansons Group Inc.

Image 19
Contents 866 456 Copyright Notice Updates and RegistrationTable of Contents Safety Precautions Safety Precautions Specifications F140 FAN Limit Switch Automatic Safety FeaturesL250 High Limit Switch L120 LOW Limit SwitchInstallation Options Include Installation OptionsFPP For your stove Installation Check ListCCI -AcuTron Board Cutaway View Maximum Venting Size Vent InstallationExhaust Systems General Pellet Vent TypeVent Termination Clearances Pellet Vent Termination Figures 7Foot Package PART# ACFAKT3 Foot Package PART# ACFAKT10 Outside air is Required on ALL Mobile Home InstallationsOutside AIR Through The Wall Kits IncludeFloor Protection Requirements Freestanding Stove InstallationStove Placement Clearances Straight InstallationAlcove Through the Wall Alcove InstallationEJ a Through the WALL, Direct INSTALLATION. FigureCOMMON, but not inclusive, Vertical Installation Designs are Vertical Installations Figures 17Mobile Home Installation Installing SOLID-FUEL Inserts Into Factory Built Fireplaces Fireplace Insert InstallationVenting Into AN Existing Chimney Full Chimney Reline Fireplace Insert Installation …BUILT-IN Insert Installation BUILT-IN Insert Installation . . . CON’T HOW Your Pelpro Stove Works Operating Your StoveLighting Your Stove Lighting stove manually No Igniter NON-Thermostat ModeBasic Overview Initial Start or SET-UP Manual or NON-THERMOSTAT ModeRE-START Manual or NON-THERMOSTAT Mode ControlsAuger Cycle Trim Pots Fine Tune Adjustments- Factory SettingsShutting the Stove OFF Controls …AIR Inlet Damper Performance Enhancement TipsHigh / LOW Cycle Option Flashing 3 OperationOn / OFF Option Flashing 1 Start Initial Appliance Burn SetupPellet Consumption Fine Tuning the Pellet Feed RatesPellet Fuel Pellet QualityFines ASH and Clinkers …PFI Pellet Standards INSERTING, Removing & Adjusting the Burn Grate Cleaning Your EZ-CLEAN GrateMAY Result Required Routine CleaningEvery 2 -3 Days / Weekly Heat Tubes Cold Stove onlySoot FLY ASH Periodic MaintenancePeriodic Maintenance … Problem Solution Trouble ShootingCheck with Dansons Customer Service Extended Warranty Limited WarrantyAppendix a Optional AccessoriesReplacement Parts Agshtls AgshtsgAgshtss AgshtlgZIP/PC Service & Maintenance Log

IPP Bay View Insert / Built-In, FPP, IPP, FPP Freestanding, IPP, FPP specifications

Dansons Group is renowned for its innovative approach to outdoor and indoor heating solutions, especially with their FPP Freestanding and IPP Bay View Insert/Built-In models. These products are designed to cater to the diverse needs of homeowners seeking both functionality and aesthetics in their heating appliances.

The FPP Freestanding model is a perfect blend of traditional charm and modern technology. It serves as an impressive centerpiece in any setting, providing warmth and ambiance to any space. One of its standout features is its large viewing area, which allows for an unobstructed view of the flames, creating a cozy and inviting atmosphere. It is equipped with advanced combustion technology that ensures efficient burning, maximizing heat output while minimizing emissions. This model is also designed to accommodate a range of fuel options, including wood and pellets, giving users the flexibility to choose what works best for them.

On the other hand, the IPP Bay View Insert/Built-In model offers a seamless integration into existing fireplaces or as a built-in feature in new constructions. This model emphasizes both performance and aesthetics, providing a sleek finish that enhances any room's decor. One of the key technologies in the IPP is its advanced blowers and distribution system, which efficiently circulates heat throughout the space, ensuring even warmth without hot spots. Additionally, the IPP incorporates a unique air-wash system that keeps the glass clean, allowing for a clear view of the flickering flames.

Both the FPP and IPP series prioritize ease of use and maintenance. They are designed with user-friendly controls that allow for easy operation and customization of heat settings. Moreover, Dansons Group emphasizes safety, incorporating features such as automatic shut-off mechanisms and cool-touch exteriors to prevent accidental burns.

In summary, the Dansons Group FPP Freestanding and IPP Bay View Insert/Built-In models stand out for their combination of aesthetic appeal, technological advancement, and user-friendly features. Whether you're looking for a statement piece or a practical heating solution, these products are designed to create a warm ambiance while ensuring efficiency and safety.