Dansons Group FPP, IPP, IPP, FPP, FPP Freestanding Pellet Fuel, Pellet Quality, Pellet Consumption

Page 29

PELLET FUEL

The performance of your pellet appliance is greatly affected by the type and quality of wood pellets burned. As the heat output of various quality wood pellets differ, so will the performance and heat output of your appliance.

PELLET QUALITY

Your PELPRO stove, with its standard “E Z Clean Grate”, is designed to burn APFI/FFI, "Premium" or "Standard" quality wood pellets. Pellets that are soft, contain excessive amounts of loose sawdust, have been or are wet, produce clinkers and/or heavy ash will result in reduced performance and may actually cause the fire to go out.

PELLET CONSUMPTION

Fuel consumption will vary somewhat between fuel brands and stoves. The following "ROUGH GUIDE" to pellet usage's may be useful in assessing your stove's operation, in ordering fuel and in providing information to your Authorized PELPRO Dealer.

Fuel Rate Setting…

Setting

 

 

Approx. Burn time on 40lb hopper

 

 

Amount of pellets burned

1

 

 

20 – 30 hours

 

 

1.50 to 2.25 lbs. Per hour

2

 

 

15 – 20 hours

 

 

2.25 to 3.00 lbs. Per hour

3

 

 

10 – 15 hours

 

 

3.50 to 4.00 lbs. Per hour

4

 

 

7 - 10 hours

 

 

4.00 to 5.50 lbs. Per hour

* Fuel flow and burn times quoted are approximate. And may vary with type of fuel used.

FACTORS EFFECTING PELLET FEED RATES

Generally, the smaller, harder and cleaner, free from fines the pellets are the faster they will feed at a given setting and visa versa. The extremes in pellet size and quality can cause several hours difference in burning time for a 40 pound bag of pellets. Heat production is directly related to the pounds of fuel burned per hour. As fuel consumption goes down so will heat output and visa versa. Pellet feed rate, at the same fuel settings, may vary greatly from brand to brand and may vary somewhat from batch to batch within the same brand.

FINE TUNING THE PELLET FEED RATES

If the fire goes out at the LO (# 1) setting the pellets being used may not be feeding fast enough. Likewise if the fire is too high, i.e. burning fuel at the LO (# 1) setting the pellets being used may be feeding too fast. The fuel feed rate for each setting may be increased or decreased somewhat to accommodate different pellets

.

NOTE: Fine tuning the feed rates beyond the fuel settings provided, involves technical adjustments that you may wish to have performed by an Authorized PELPRO Dealer. There may be a service charge for these adjustments.

ASH and CLINKERS

Ash is a by-product of all pellets. Clinkers may be produced from some pellets and not from others. High quality pellets will produce less ash and fewer clinkers than lower quality pellets.

ASH is a natural product of burning wood. As the amount of ash in the wood increases the amount of ash left after burning high ash wood pellets will increase.

Canadian Comfort Industries V04

29

PELPRO OWNERS MANUAL

Copyright 2004

www.pelprostoves.com

Dansons Group Inc.

Image 29
Contents 866 456 Copyright Notice Updates and RegistrationTable of Contents Safety Precautions Safety Precautions Specifications L250 High Limit Switch Automatic Safety FeaturesL120 LOW Limit Switch F140 FAN Limit SwitchFPP Installation OptionsInstallation Options Include CCI -AcuTron Board Cutaway View Installation Check ListFor your stove Exhaust Systems General Vent InstallationPellet Vent Type Maximum Venting SizeVent Termination Clearances Pellet Vent Termination Figures 7Outside AIR Outside air is Required on ALL Mobile Home InstallationsThrough The Wall Kits Include Foot Package PART# ACFAKT3 Foot Package PART# ACFAKT10Stove Placement Freestanding Stove InstallationClearances Straight Installation Floor Protection RequirementsAlcove Through the Wall Alcove InstallationEJ a Through the WALL, Direct INSTALLATION. FigureCOMMON, but not inclusive, Vertical Installation Designs are Vertical Installations Figures 17Mobile Home Installation Venting Into AN Existing Chimney Fireplace Insert InstallationInstalling SOLID-FUEL Inserts Into Factory Built Fireplaces Full Chimney Reline Fireplace Insert Installation …BUILT-IN Insert Installation BUILT-IN Insert Installation . . . CON’T HOW Your Pelpro Stove Works Operating Your StoveLighting Your Stove Lighting stove manually No Igniter NON-Thermostat ModeRE-START Manual or NON-THERMOSTAT Mode Initial Start or SET-UP Manual or NON-THERMOSTAT ModeControls Basic OverviewShutting the Stove OFF Trim Pots Fine Tune Adjustments- Factory SettingsControls … Auger CycleAIR Inlet Damper Performance Enhancement TipsOn / OFF Option Flashing 1 OperationHigh / LOW Cycle Option Flashing 3 Start Initial Appliance Burn SetupPellet Fuel Fine Tuning the Pellet Feed RatesPellet Quality Pellet ConsumptionPFI Pellet Standards ASH and Clinkers …Fines INSERTING, Removing & Adjusting the Burn Grate Cleaning Your EZ-CLEAN GrateEvery 2 -3 Days / Weekly Required Routine CleaningHeat Tubes Cold Stove only MAY ResultSoot FLY ASH Periodic MaintenancePeriodic Maintenance … Check with Dansons Customer Service Trouble ShootingProblem Solution Extended Warranty Limited WarrantyAppendix a Optional AccessoriesReplacement Parts Agshtss AgshtsgAgshtlg AgshtlsZIP/PC Service & Maintenance Log

IPP Bay View Insert / Built-In, FPP, IPP, FPP Freestanding, IPP, FPP specifications

Dansons Group is renowned for its innovative approach to outdoor and indoor heating solutions, especially with their FPP Freestanding and IPP Bay View Insert/Built-In models. These products are designed to cater to the diverse needs of homeowners seeking both functionality and aesthetics in their heating appliances.

The FPP Freestanding model is a perfect blend of traditional charm and modern technology. It serves as an impressive centerpiece in any setting, providing warmth and ambiance to any space. One of its standout features is its large viewing area, which allows for an unobstructed view of the flames, creating a cozy and inviting atmosphere. It is equipped with advanced combustion technology that ensures efficient burning, maximizing heat output while minimizing emissions. This model is also designed to accommodate a range of fuel options, including wood and pellets, giving users the flexibility to choose what works best for them.

On the other hand, the IPP Bay View Insert/Built-In model offers a seamless integration into existing fireplaces or as a built-in feature in new constructions. This model emphasizes both performance and aesthetics, providing a sleek finish that enhances any room's decor. One of the key technologies in the IPP is its advanced blowers and distribution system, which efficiently circulates heat throughout the space, ensuring even warmth without hot spots. Additionally, the IPP incorporates a unique air-wash system that keeps the glass clean, allowing for a clear view of the flickering flames.

Both the FPP and IPP series prioritize ease of use and maintenance. They are designed with user-friendly controls that allow for easy operation and customization of heat settings. Moreover, Dansons Group emphasizes safety, incorporating features such as automatic shut-off mechanisms and cool-touch exteriors to prevent accidental burns.

In summary, the Dansons Group FPP Freestanding and IPP Bay View Insert/Built-In models stand out for their combination of aesthetic appeal, technological advancement, and user-friendly features. Whether you're looking for a statement piece or a practical heating solution, these products are designed to create a warm ambiance while ensuring efficiency and safety.