THE CONTROLS CONTINUED

TRIM POTS (Fine Tune Adjustments)– Factory Settings

The COMBUSTION FAN (FAN), HI (4) and LO (1) FEED RATE trim pots have been preset at the

 

 

factory, but may need to be adjusted onsite after your installation is complete. Due to different

 

 

installation setups, length and size of venting, and pellet fuel quality, the preset from the factory will

 

 

not always be correct. These settings will accommodate virtually all wood pellet fuels.

Decrease

Increase

 

FUEL FEED rates at the Lowest (number 1) and highest (number 4) settings can be adjusted by

FINE TUNE ADJUSTMENTS

adjusting the fine tune trim pots located on the control panel. To raise fuel feed turn trim pot

 

 

counter clockwise and to lower turn clockwise. To assist in knowing what the change is you

 

 

should note the amount of time the light on the AUGER CYCLE LED stays OFF. (Note: The light

 

 

stays on when ever the fuel feed motor, AUGER CYCLE, is running). Lengthening the time this

1

4

LED stays OFF lowers the fuel feed and shortening the off-time increases the fuel feed.

 

 

COMBUSTION FAN SPEED (FAN)

 

FAN

In a few instances because of prevailing conditions pertinent to your specific installation, or even

 

 

different batches of pellet fuel, the COMBUSTION FAN SPEED may be adjusted to raise or lower

 

 

the amount of air moving through the grate for the cleanest burn. The FAN speed can be adjusted

 

 

by adjusting the FAN trim pot COUNTER CLOCKWISE to INCREASE the speed and CLOCKWISE to DECREASE the speed of the combustion fan.

Note: If you attempt to adjust the Fuel Feed Trim Pots, use a small precision screwdriver. The Trim Pots do not make a full rotation.

If using a metal screwdriver, be gentle as the plastic trim pot slot can be damaged or stripped.

FAN SPEED (Convection or heating)

The FAN SPEED controls the speed of the room air fan. This fan blows room air through the heat exchange tubes and back into the room. When the FEED RATE is set to a higher position, the FAN SPEED should be set higher and visa versa. When the FEED RATE is set at [3 OR 4] set the FAN SPEED to [MED]. If you forget, the room air fan's (L140) temperature limit snap switch automatically sets the fan on high when your stove is producing heat faster than the fan is carrying it into the room. This may occur when the heat control lever is set at [3 or 4] and the FAN SPEED is set to a very low or off setting. After the fan runs at this automatic high setting a few minutes, it may cycle back to its lower setting and may continue to cycle between [HIGH ] and your selected setting. The circulation (room air) fan cycling from high to low is a normal condition, as well as a safety feature of

your appliance.

AUGER CYCLE

The AUGER CYCLE LED indicates when a electrical signal is being sent to the auger motor. It is NOT used to indicate the actual movement of the auger. When the signal is being sent the LED will be solid for 3 seconds. When the LED is off no signal is being sent.

FAN SPEED

HI

 

MED

AUGER

 

CYCLE

LOW

 

 

FAN

 

SPEED

 

OFF

SHUTTING THE STOVE OFF

Note: DO NOT UNPLUG your stove if there is a fire going or if the stove is still active. This could result in smoke coming back into the room. Remember the EXHAUST FAN is needed to force the exhaust out of the stove.

On the CCI “AcuTron” Board firmly touch the OFF touch pad. The FUEL RATE LED will turn off. The AUGER CYCLE LED will turn off. The auger will stop feeding fuel to the fire and the FAN speed LED will flash indicating that the appliance is in the “Shut Down” mode. The fire will go out and the fans will continue to run until your stove cools down at which time the fans will automatically shut off and NO LED’s will remain ON.

Canadian Comfort Industries V04

25

PELPRO OWNERS MANUAL

Copyright 2004

www.pelprostoves.com

Dansons Group Inc.

Image 25
Contents 866 456 Copyright Notice Updates and RegistrationTable of Contents Safety Precautions Safety Precautions Specifications L250 High Limit Switch Automatic Safety FeaturesL120 LOW Limit Switch F140 FAN Limit SwitchInstallation Options Include Installation OptionsFPP For your stove Installation Check ListCCI -AcuTron Board Cutaway View Exhaust Systems General Vent InstallationPellet Vent Type Maximum Venting SizeVent Termination Clearances Pellet Vent Termination Figures 7Outside AIR Outside air is Required on ALL Mobile Home InstallationsThrough The Wall Kits Include Foot Package PART# ACFAKT3 Foot Package PART# ACFAKT10Stove Placement Freestanding Stove InstallationClearances Straight Installation Floor Protection RequirementsAlcove Through the Wall Alcove InstallationEJ a Through the WALL, Direct INSTALLATION. FigureCOMMON, but not inclusive, Vertical Installation Designs are Vertical Installations Figures 17Mobile Home Installation Installing SOLID-FUEL Inserts Into Factory Built Fireplaces Fireplace Insert InstallationVenting Into AN Existing Chimney Full Chimney Reline Fireplace Insert Installation …BUILT-IN Insert Installation BUILT-IN Insert Installation . . . CON’T HOW Your Pelpro Stove Works Operating Your StoveLighting Your Stove Lighting stove manually No Igniter NON-Thermostat ModeRE-START Manual or NON-THERMOSTAT Mode Initial Start or SET-UP Manual or NON-THERMOSTAT ModeControls Basic OverviewShutting the Stove OFF Trim Pots Fine Tune Adjustments- Factory SettingsControls … Auger CycleAIR Inlet Damper Performance Enhancement TipsHigh / LOW Cycle Option Flashing 3 OperationOn / OFF Option Flashing 1 Start Initial Appliance Burn SetupPellet Fuel Fine Tuning the Pellet Feed RatesPellet Quality Pellet ConsumptionFines ASH and Clinkers …PFI Pellet Standards INSERTING, Removing & Adjusting the Burn Grate Cleaning Your EZ-CLEAN GrateEvery 2 -3 Days / Weekly Required Routine CleaningHeat Tubes Cold Stove only MAY ResultSoot FLY ASH Periodic MaintenancePeriodic Maintenance … Problem Solution Trouble ShootingCheck with Dansons Customer Service Extended Warranty Limited WarrantyAppendix a Optional AccessoriesReplacement Parts Agshtss AgshtsgAgshtlg AgshtlsZIP/PC Service & Maintenance Log

IPP Bay View Insert / Built-In, FPP, IPP, FPP Freestanding, IPP, FPP specifications

Dansons Group is renowned for its innovative approach to outdoor and indoor heating solutions, especially with their FPP Freestanding and IPP Bay View Insert/Built-In models. These products are designed to cater to the diverse needs of homeowners seeking both functionality and aesthetics in their heating appliances.

The FPP Freestanding model is a perfect blend of traditional charm and modern technology. It serves as an impressive centerpiece in any setting, providing warmth and ambiance to any space. One of its standout features is its large viewing area, which allows for an unobstructed view of the flames, creating a cozy and inviting atmosphere. It is equipped with advanced combustion technology that ensures efficient burning, maximizing heat output while minimizing emissions. This model is also designed to accommodate a range of fuel options, including wood and pellets, giving users the flexibility to choose what works best for them.

On the other hand, the IPP Bay View Insert/Built-In model offers a seamless integration into existing fireplaces or as a built-in feature in new constructions. This model emphasizes both performance and aesthetics, providing a sleek finish that enhances any room's decor. One of the key technologies in the IPP is its advanced blowers and distribution system, which efficiently circulates heat throughout the space, ensuring even warmth without hot spots. Additionally, the IPP incorporates a unique air-wash system that keeps the glass clean, allowing for a clear view of the flickering flames.

Both the FPP and IPP series prioritize ease of use and maintenance. They are designed with user-friendly controls that allow for easy operation and customization of heat settings. Moreover, Dansons Group emphasizes safety, incorporating features such as automatic shut-off mechanisms and cool-touch exteriors to prevent accidental burns.

In summary, the Dansons Group FPP Freestanding and IPP Bay View Insert/Built-In models stand out for their combination of aesthetic appeal, technological advancement, and user-friendly features. Whether you're looking for a statement piece or a practical heating solution, these products are designed to create a warm ambiance while ensuring efficiency and safety.