SAFETY PRECAUTIONS

oDo not operate the heater if you smell smoke coming from the heater. Push the “OFF” Touch pad, monitor your heater, and call your dealer.

oNever use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or ’freshen up’ a fire in this heater. Keep all such liquids well away from the heater while it is in use.

oDon’t unplug the heater if you suspect a malfunction. Push the “OFF” Touch pad and inspect the heater.

oDo not operate the heater if the flame becomes dark & sooty or if the firepot overfills with pellets. Push the ”OFF” Touch pad and periodically inspect the heater (see ”Operating Your Stove”).

oNever try to repair or replace any part of the heater unless instructions for consumer are given in this manual. All other work should be done by a trained technician.

oThe viewing door and ash pan must be closed and latched during operation.

oNever block free airflow through the open vents of the unit.

oContact your local building officials to obtain a permit and information on any installation restrictions or inspection requirements in your area. Notify your insurance company of this heater as well.

oThe pellet appliance exhaust system works with negative combustion chamber pressure and a slightly positive chimney pressure, therefore the exhaust system must be completely airtight and properly installed. All pellet vent joints must be sealed with HI-TEMP RTV silicone sealant and at least 3 sheet metal screws, to each other as well as to the heater.

oThis unit must be properly installed to prevent the possibility of a house fire. The instructions must be strictly adhered to. Do not use makeshift methods, which may compromise the installation.

oYour heater requires periodic maintenance and cleaning (see ”Operating Your Stove”). Failure to maintain your heater may lead to smoke spillage in your home.

oAllow the heater to cool before carrying out any maintenance or cleaning. Ashes must be disposed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a non-combustible surface or on the ground, well away from all combustible materials, pending final disposal.

oThis heater is designed and approved for pelletized wood fuel only. Any other type of fuel burned in this heater will void the warranty and safety listing.

oThe heater will not operate during a power outage. If a power outage does occur, check the heater for smoke spillage and open a window if any smoke spills into the room.

oKeep foreign objects out of the hopper.

Canadian Comfort Industries V04

4

PELPRO OWNERS MANUAL

Copyright 2004

www.pelprostoves.com

Dansons Group Inc.

Image 4
Contents 866 456 Updates and Registration Copyright NoticeTable of Contents Safety Precautions Safety Precautions Specifications Automatic Safety Features L250 High Limit SwitchL120 LOW Limit Switch F140 FAN Limit SwitchInstallation Options Include Installation OptionsFPP For your stove Installation Check ListCCI -AcuTron Board Cutaway View Vent Installation Exhaust Systems GeneralPellet Vent Type Maximum Venting SizePellet Vent Termination Figures 7 Vent Termination ClearancesOutside air is Required on ALL Mobile Home Installations Outside AIRThrough The Wall Kits Include Foot Package PART# ACFAKT3 Foot Package PART# ACFAKT10Freestanding Stove Installation Stove PlacementClearances Straight Installation Floor Protection RequirementsAlcove Installation Alcove Through the WallThrough the WALL, Direct INSTALLATION. Figure EJ aVertical Installations Figures 17 COMMON, but not inclusive, Vertical Installation Designs areMobile Home Installation Installing SOLID-FUEL Inserts Into Factory Built Fireplaces Fireplace Insert InstallationVenting Into AN Existing Chimney Fireplace Insert Installation … Full Chimney RelineBUILT-IN Insert Installation BUILT-IN Insert Installation . . . CON’T Operating Your Stove HOW Your Pelpro Stove WorksLighting stove manually No Igniter NON-Thermostat Mode Lighting Your StoveInitial Start or SET-UP Manual or NON-THERMOSTAT Mode RE-START Manual or NON-THERMOSTAT ModeControls Basic OverviewTrim Pots Fine Tune Adjustments- Factory Settings Shutting the Stove OFFControls … Auger CyclePerformance Enhancement Tips AIR Inlet DamperHigh / LOW Cycle Option Flashing 3 OperationOn / OFF Option Flashing 1 Initial Appliance Burn Setup StartFine Tuning the Pellet Feed Rates Pellet FuelPellet Quality Pellet ConsumptionFines ASH and Clinkers …PFI Pellet Standards Cleaning Your EZ-CLEAN Grate INSERTING, Removing & Adjusting the Burn GrateRequired Routine Cleaning Every 2 -3 Days / WeeklyHeat Tubes Cold Stove only MAY ResultPeriodic Maintenance Soot FLY ASHPeriodic Maintenance … Problem Solution Trouble ShootingCheck with Dansons Customer Service Limited Warranty Extended WarrantyOptional Accessories Appendix aReplacement Parts Agshtsg AgshtssAgshtlg AgshtlsService & Maintenance Log ZIP/PC

IPP Bay View Insert / Built-In, FPP, IPP, FPP Freestanding, IPP, FPP specifications

Dansons Group is renowned for its innovative approach to outdoor and indoor heating solutions, especially with their FPP Freestanding and IPP Bay View Insert/Built-In models. These products are designed to cater to the diverse needs of homeowners seeking both functionality and aesthetics in their heating appliances.

The FPP Freestanding model is a perfect blend of traditional charm and modern technology. It serves as an impressive centerpiece in any setting, providing warmth and ambiance to any space. One of its standout features is its large viewing area, which allows for an unobstructed view of the flames, creating a cozy and inviting atmosphere. It is equipped with advanced combustion technology that ensures efficient burning, maximizing heat output while minimizing emissions. This model is also designed to accommodate a range of fuel options, including wood and pellets, giving users the flexibility to choose what works best for them.

On the other hand, the IPP Bay View Insert/Built-In model offers a seamless integration into existing fireplaces or as a built-in feature in new constructions. This model emphasizes both performance and aesthetics, providing a sleek finish that enhances any room's decor. One of the key technologies in the IPP is its advanced blowers and distribution system, which efficiently circulates heat throughout the space, ensuring even warmth without hot spots. Additionally, the IPP incorporates a unique air-wash system that keeps the glass clean, allowing for a clear view of the flickering flames.

Both the FPP and IPP series prioritize ease of use and maintenance. They are designed with user-friendly controls that allow for easy operation and customization of heat settings. Moreover, Dansons Group emphasizes safety, incorporating features such as automatic shut-off mechanisms and cool-touch exteriors to prevent accidental burns.

In summary, the Dansons Group FPP Freestanding and IPP Bay View Insert/Built-In models stand out for their combination of aesthetic appeal, technological advancement, and user-friendly features. Whether you're looking for a statement piece or a practical heating solution, these products are designed to create a warm ambiance while ensuring efficiency and safety.