INTRODUCTION ------------------------------------------------------------------------------------

2

TABLE OF CONTENTS ----------------------------------------------------------------------------

3

SAFETY PRECAUTIONS -------------------------------------------------------------------------

4,5

SPECIFICATIONS ---------------------------------------------------------------------------------

6

AUTOMATIC SAFETY FEATURES --------------------------------------------------------------

7

INSTALLATION OPTIONS -----------------------------------------------------------------------

8

INSTALLATION CHECK LIST -------------------------------------------------------------------

9

EXHAUST SYSTEMS ------------------------------------------------------------------------------

10

GENERAL ----------------------------------------------------------------------------------------

10

SIZING ---------------------------------------------------------------------------------------------

10

TERMINATION ----------------------------------------------------------------------------------

11

CLEARANCES -----------------------------------------------------------------------------------

11

OUTSIDE AIR ----------------------------------------------------------------------------------------

12

FREESTANDING INSTALLATION --------------------------------------------------------------

13

STOVE PLACEMENT ---------------------------------------------------------------------------

13

FLOOR PROTECTION -------------------------------------------------------------------------

13

CLEARANCES ----------------------------------------------------------------------------------

13,14

ALCOVE -------------------------------------------------------------------------------------------

14

THROUGH THE WALL DIRECT INSTALLATION -------------------------------------

15

VERTICAL INSTALLATIONS ----------------------------------------------------------------

16

MOBILE HOME INSTALLATION ----------------------------------------------------------------

17

INSERT / BUILT-IN INSTALLATION

 

IN A WOOD OR COAL BURNING FIREPLACE ----------------------------------------

18,19

IN A WALL OR MANTEL ----------------------------------------------------------------------

20,21

OPERATING YOUR STOVE ---------------------------------------------------------------------

22

HOW YOUR PELPRO STOVE WORKS ------------------------------------------------------

22

LIGHTING A FIRE ----------------------------------------------------------------------------------

23

THE ACUTRON CONTROLS --------------------------------------------------------------------

24,25

SHUTTING THE STOVE OFF -------------------------------------------------------------------

25

PERFORMANCE ENHANCEMENT TIPS -----------------------------------------------------

26

ACUTRON WALL THERMOSTAT (OPTIONAL) -------------------------------------------

27

INITIAL BURN SETUP -----------------------------------------------------------------------------

28

PELLETS

 

PELLET QUALITY ------------------------------------------------------------------------------

29

PELLET CONSUMPTION ---------------------------------------------------------------------

29

FACTORS EFFECTING PELLET FEED RATES ---------------------------------------

29

FINE TUNING THE PELLET FEED RATES ----------------------------------------------

29

ASH and CLINKERS ---------------------------------------------------------------------------

30

FINES ---------------------------------------------------------------------------------------------

30

PFI PELLET STANDARDS -------------------------------------------------------------------

30

INSERTING, REMOVING, AND ADJUSTING THE BURN GRATE ---------------------

31

REQUIRED CLEANING ---------------------------------------------------------------------------

32

PERIODIC MAINTENANCE ----------------------------------------------------------------------

33-34

TROUBLE SHOOTING ----------------------------------------------------------------------------

35

LIMITED WARRANTY -----------------------------------------------------------------------------

36

APPENDIX “A” - PELPRO OPTIONS -----------------------------------------------------------

37

APPENDIX “B” – PELPRO ACCESSORIES -------------------------------------------------

38,39

SERVICE LOG --------------------------------------------------------------------------------------

40

Canadian Comfort Industries V04

3

PELPRO OWNERS MANUAL

Copyright 2004

www.pelprostoves.com

Dansons Group Inc.

Image 3
Contents 866 456 Copyright Notice Updates and RegistrationTable of Contents Safety Precautions Safety Precautions Specifications F140 FAN Limit Switch Automatic Safety FeaturesL250 High Limit Switch L120 LOW Limit SwitchInstallation Options Installation Options IncludeFPP Installation Check List For your stoveCCI -AcuTron Board Cutaway View Maximum Venting Size Vent InstallationExhaust Systems General Pellet Vent TypeVent Termination Clearances Pellet Vent Termination Figures 7Foot Package PART# ACFAKT3 Foot Package PART# ACFAKT10 Outside air is Required on ALL Mobile Home InstallationsOutside AIR Through The Wall Kits IncludeFloor Protection Requirements Freestanding Stove InstallationStove Placement Clearances Straight InstallationAlcove Through the Wall Alcove InstallationEJ a Through the WALL, Direct INSTALLATION. FigureCOMMON, but not inclusive, Vertical Installation Designs are Vertical Installations Figures 17Mobile Home Installation Fireplace Insert Installation Installing SOLID-FUEL Inserts Into Factory Built FireplacesVenting Into AN Existing Chimney Full Chimney Reline Fireplace Insert Installation …BUILT-IN Insert Installation BUILT-IN Insert Installation . . . CON’T HOW Your Pelpro Stove Works Operating Your StoveLighting Your Stove Lighting stove manually No Igniter NON-Thermostat ModeBasic Overview Initial Start or SET-UP Manual or NON-THERMOSTAT ModeRE-START Manual or NON-THERMOSTAT Mode ControlsAuger Cycle Trim Pots Fine Tune Adjustments- Factory SettingsShutting the Stove OFF Controls …AIR Inlet Damper Performance Enhancement TipsOperation High / LOW Cycle Option Flashing 3On / OFF Option Flashing 1 Start Initial Appliance Burn SetupPellet Consumption Fine Tuning the Pellet Feed RatesPellet Fuel Pellet QualityASH and Clinkers … FinesPFI Pellet Standards INSERTING, Removing & Adjusting the Burn Grate Cleaning Your EZ-CLEAN GrateMAY Result Required Routine CleaningEvery 2 -3 Days / Weekly Heat Tubes Cold Stove onlySoot FLY ASH Periodic MaintenancePeriodic Maintenance … Trouble Shooting Problem SolutionCheck with Dansons Customer Service Extended Warranty Limited WarrantyAppendix a Optional AccessoriesReplacement Parts Agshtls AgshtsgAgshtss AgshtlgZIP/PC Service & Maintenance Log

IPP Bay View Insert / Built-In, FPP, IPP, FPP Freestanding, IPP, FPP specifications

Dansons Group is renowned for its innovative approach to outdoor and indoor heating solutions, especially with their FPP Freestanding and IPP Bay View Insert/Built-In models. These products are designed to cater to the diverse needs of homeowners seeking both functionality and aesthetics in their heating appliances.

The FPP Freestanding model is a perfect blend of traditional charm and modern technology. It serves as an impressive centerpiece in any setting, providing warmth and ambiance to any space. One of its standout features is its large viewing area, which allows for an unobstructed view of the flames, creating a cozy and inviting atmosphere. It is equipped with advanced combustion technology that ensures efficient burning, maximizing heat output while minimizing emissions. This model is also designed to accommodate a range of fuel options, including wood and pellets, giving users the flexibility to choose what works best for them.

On the other hand, the IPP Bay View Insert/Built-In model offers a seamless integration into existing fireplaces or as a built-in feature in new constructions. This model emphasizes both performance and aesthetics, providing a sleek finish that enhances any room's decor. One of the key technologies in the IPP is its advanced blowers and distribution system, which efficiently circulates heat throughout the space, ensuring even warmth without hot spots. Additionally, the IPP incorporates a unique air-wash system that keeps the glass clean, allowing for a clear view of the flickering flames.

Both the FPP and IPP series prioritize ease of use and maintenance. They are designed with user-friendly controls that allow for easy operation and customization of heat settings. Moreover, Dansons Group emphasizes safety, incorporating features such as automatic shut-off mechanisms and cool-touch exteriors to prevent accidental burns.

In summary, the Dansons Group FPP Freestanding and IPP Bay View Insert/Built-In models stand out for their combination of aesthetic appeal, technological advancement, and user-friendly features. Whether you're looking for a statement piece or a practical heating solution, these products are designed to create a warm ambiance while ensuring efficiency and safety.