Dansons Group FPP, IPP, IPP, FPP, FPP Freestanding manual Safety Precautions

Page 5

SAFETY PRECAUTIONS . . . Continued

oDisconnect the power cord before performing any maintenance. NOTE: Touching the OFF touch pad does not disconnect all power to the heater.

oDo not throw this manual away. This manual has important operating and maintenance instructions that you will need at a later time. Always follow the instructions in this manual.

oDo not place clothing or other flammable items on or near the heater. Because this heater can be controlled by a thermostat there is a possibility of the heater turning on and igniting any items placed on or near it.

oThis heater must be connected to a standard 110 - 120V., 60 Hz grounded electrical outlet. Do not use an adapter plug or sever the grounding plug. Do not route the electrical cord underneath,

in front of, or over the heater.

oIt is recommended to connect the heater to a standard 110 – 120V ground surge protected unit or surge protected electrical outlet..

oWhen installed in a mobile home, the heater must be bolted to the floor, have outside air, and MUST NOT BE INSTALLED IN THE BEDROOM (Per H.U.D. requirements). Check with local building officials.

oEducate all children on the dangers of a high-temperature heater.

oYoung children should be supervised when they are in the same room as the heater.

oCaution: NEVER PUT FINGERS NEAR AUGER. Pellet fuel is fed to the burn pot by a screw auger that is driven by a high torque motor. The auger can start and stop automatically anytime while the heater is operating.

oDo not connect this appliance directly to air ducts or any air distribution system. This will void your warranty.

oDo not burn with insufficient combustion air. A periodic check is recommended to ensure proper combustion air is admitted to the combustion chamber. Setting the proper combustion air is achieved by adjusting the slide damper located on the right hand side of the appliance.

oIt is advisable to clean the exhaust vent bi-annually or every two tons of pellets.

oSoot or creosote may accumulate when the stove is operated under incorrect conditions such as an extremely rich burn (black tipped, lazy orange flames).

Note: Canadian Comfort Industries grants no warranty, implied or stated, for the installation or maintenance of your heater, and assumes no responsibility of any consequential damage(s).

Canadian Comfort Industries V04

5

PELPRO OWNERS MANUAL

Copyright 2004

www.pelprostoves.com

Dansons Group Inc.

Image 5
Contents 866 456 Copyright Notice Updates and RegistrationTable of Contents Safety Precautions Safety Precautions Specifications L250 High Limit Switch Automatic Safety FeaturesL120 LOW Limit Switch F140 FAN Limit SwitchFPP Installation OptionsInstallation Options Include CCI -AcuTron Board Cutaway View Installation Check ListFor your stove Exhaust Systems General Vent InstallationPellet Vent Type Maximum Venting SizeVent Termination Clearances Pellet Vent Termination Figures 7Outside AIR Outside air is Required on ALL Mobile Home InstallationsThrough The Wall Kits Include Foot Package PART# ACFAKT3 Foot Package PART# ACFAKT10Stove Placement Freestanding Stove InstallationClearances Straight Installation Floor Protection RequirementsAlcove Through the Wall Alcove InstallationEJ a Through the WALL, Direct INSTALLATION. FigureCOMMON, but not inclusive, Vertical Installation Designs are Vertical Installations Figures 17Mobile Home Installation Venting Into AN Existing Chimney Fireplace Insert InstallationInstalling SOLID-FUEL Inserts Into Factory Built Fireplaces Full Chimney Reline Fireplace Insert Installation …BUILT-IN Insert Installation BUILT-IN Insert Installation . . . CON’T HOW Your Pelpro Stove Works Operating Your StoveLighting Your Stove Lighting stove manually No Igniter NON-Thermostat ModeRE-START Manual or NON-THERMOSTAT Mode Initial Start or SET-UP Manual or NON-THERMOSTAT ModeControls Basic OverviewShutting the Stove OFF Trim Pots Fine Tune Adjustments- Factory SettingsControls … Auger CycleAIR Inlet Damper Performance Enhancement TipsOn / OFF Option Flashing 1 OperationHigh / LOW Cycle Option Flashing 3 Start Initial Appliance Burn SetupPellet Fuel Fine Tuning the Pellet Feed RatesPellet Quality Pellet ConsumptionPFI Pellet Standards ASH and Clinkers …Fines INSERTING, Removing & Adjusting the Burn Grate Cleaning Your EZ-CLEAN GrateEvery 2 -3 Days / Weekly Required Routine CleaningHeat Tubes Cold Stove only MAY ResultSoot FLY ASH Periodic MaintenancePeriodic Maintenance … Check with Dansons Customer Service Trouble ShootingProblem Solution Extended Warranty Limited WarrantyAppendix a Optional AccessoriesReplacement Parts Agshtss AgshtsgAgshtlg AgshtlsZIP/PC Service & Maintenance Log

IPP Bay View Insert / Built-In, FPP, IPP, FPP Freestanding, IPP, FPP specifications

Dansons Group is renowned for its innovative approach to outdoor and indoor heating solutions, especially with their FPP Freestanding and IPP Bay View Insert/Built-In models. These products are designed to cater to the diverse needs of homeowners seeking both functionality and aesthetics in their heating appliances.

The FPP Freestanding model is a perfect blend of traditional charm and modern technology. It serves as an impressive centerpiece in any setting, providing warmth and ambiance to any space. One of its standout features is its large viewing area, which allows for an unobstructed view of the flames, creating a cozy and inviting atmosphere. It is equipped with advanced combustion technology that ensures efficient burning, maximizing heat output while minimizing emissions. This model is also designed to accommodate a range of fuel options, including wood and pellets, giving users the flexibility to choose what works best for them.

On the other hand, the IPP Bay View Insert/Built-In model offers a seamless integration into existing fireplaces or as a built-in feature in new constructions. This model emphasizes both performance and aesthetics, providing a sleek finish that enhances any room's decor. One of the key technologies in the IPP is its advanced blowers and distribution system, which efficiently circulates heat throughout the space, ensuring even warmth without hot spots. Additionally, the IPP incorporates a unique air-wash system that keeps the glass clean, allowing for a clear view of the flickering flames.

Both the FPP and IPP series prioritize ease of use and maintenance. They are designed with user-friendly controls that allow for easy operation and customization of heat settings. Moreover, Dansons Group emphasizes safety, incorporating features such as automatic shut-off mechanisms and cool-touch exteriors to prevent accidental burns.

In summary, the Dansons Group FPP Freestanding and IPP Bay View Insert/Built-In models stand out for their combination of aesthetic appeal, technological advancement, and user-friendly features. Whether you're looking for a statement piece or a practical heating solution, these products are designed to create a warm ambiance while ensuring efficiency and safety.