Maintenance And Service

BURNER REMOVAL:

The burner may need to be removed for a few reasons, including cleaning under the burner, converting the unit to a different gas type, or to replace the burner altogether. Proceed only when the unit has

completely cooled down.

1. Remove the fascia or louvers

2. Remove

the

glass as shown in the

MAINTENANCE AND SERVICE - GLASS DOOR

REMOVAL.

 

 

 

3. Remove

the

brick panels

as shown

in SECONDARY

INSTALLATION

- OPTIONAL

CERAMIC BRICK PANEL INSTALLATION.

4.

Remove the left and right firebox

 

 

corners.

 

5.

Remove the six (6) T-20 screws that hold

 

 

the burner in place; three (3) along the

 

 

top and three (3) along the bottom.

 

6.

Lift the burner straight up then out.

Figure 9. Removing Burner.

To re-install the burner follow steps 1-6 in reverse. When placing the burner back in the unit ensure that the venturi box under the burner is lined up.

FUEL CONVERSION:

TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY

Please read and understand these instructions before installing.

Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper or complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.

Kit Parts List:

1 - Orifice (NG - #39 DMS or LP - #53 DMS)

1 - Pilot Injector (NG 0.62 mm; LP 0.35 mm)

1 - Installation instruction sheet

1 - Conversion label

Carefully inspect all parts supplied with this conversion kit. If any parts have been damaged or are missing, contact your dealer, distributor or courier company to have them replaced before starting this installation.

11

Image 11
Contents R E C T V E N T F I R E P L a C E For Your SafetyGeneral Safety PrecautionsTable of Contents This Enviro DV36 Fireplace Codes And ApprovalsVented GAS Fireplace Heater DV36 NG/LPG Installation Options SpecificationsOperating Instructions For Your Safety Read BeforeBlue, the fireplace is getting too much Component Sound & Reason To Turn GAS Fireplace OFFMaintenance And Service Bottom latches for glass Never Operate Fireplace with the glass RemovedCompletely cooled down Kit Parts ListRemoving valve Screw Conversion Kit InstallationRing on valve screw Qualified Installers only Initial InstallationDo not interfere with the structural integrity of the walls Mantel Clearances Vent Termination Restrictions KIT Components Installation InstructionsManufacturer Trade Name Nominal Sizes Installation of Fireplace Horizontal Vent Kit4DSC Two 2 piece wall Vent restrictor is located in the center Being Attached to Wood Vertical Vent Termination AssembleRoof Pitch Minimum Height H Feet Meters Use of Wall Straps Installation of Electrical Wiring for the Optional FAN KIT To Test Valve Pressures GAS Line ConnectionEmpty firebox with grate and locator pins Secondary InstallationThird Stage Log Set Installation Complete log set-up with embers Never operate the fireplace with the glass door removedBack Panel In Place Turn off the gas control knob and allow the unit to coolKit Contents Hook Fan Tabs Over Grommets at Unit Back Installation of KitProblem Possible Cause Solution Trouble ShootingReference Part Description Part Number Parts ListParts List Options Parts Diagram To the Distributor WarrantyTo the Dealer Installation Data Sheet