Enviro DV36 owner manual Conversion Kit Installation, Removing valve Screw

Page 12

Maintenance And Service

Conversion Kit Installation:

1.Turn control knob on the gas valve to the “OFF” position and shut the gas supply off at the shut-off valve upstream of the unit. CAUTION: The gas supply must be shut off prior to disconnecting the electrical power and before proceeding with the conversion. Allow the valve and unit to cool down to room temperature.

2.Remove the glass as shown in the MAINTENANCE AND SERVICE - GLASS DOOR REMOVAL.

3.Carefully remove the log set and ember material if they are installed.

4.Remove the burner as shown in the MAINTENANCE AND SERVICE - BURNER REMOVAL.

5.Convert the burner orifice(s):

a)Remove the main burner orifice with a 1⁄2 inch deep socket.

b)Put a bead of pipe-thread sealant or approved Teflon tape on the orifice threads before installing into the brass elbow.

c)Install the new orifice(s) from the kit into the brass elbow.

6.Convert the pilot injector:

a)Pull the pilot hood straight up to access the pilot injector.

b)Using a 5/32” or 4 mm Allen key, remove the pilot injector.

c)Install the new pilot injector supplied with this conversion kit. Simply screw the new injector inside the pilot hood using the Allen key,

d)Reinstall the hood by placing the hood on the assembly, line up the key way, and snap into place.

7.Convert the SIT gas valve:

a)Remove the black protection cap from the HI/LO knob by hand shown in Figure 10.

Figure 11: Removing valve

screw.

b)Insert a 5/32” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 11), rotate it counter-clockwise until it is free and extract it.

c)Check that the screw is clean and if necessary remove dirt.

d)Flip the screw (refer to Figure 12).

e)Using the Allen wrench as shown in Figure 11, rotate the screw clockwise until a torque of 9 inch lbs. WARNING! Do not over tighten the screw. It is recommended that you grip the wrench by the short side.

f)Verify that if the conversion is from NG to LPG, the screw must be re-assembled with the red o- ring visible (refer to Figure 13). If the conversion is from LPG to NG, the red o-ring of the screw must be not visible.

Figure 10: Removing

valve cap.

Figure 12: Flip valve

screw.

12

Image 12
Contents For Your Safety R E C T V E N T F I R E P L a C ESafety Precautions GeneralTable of Contents Codes And Approvals Vented GAS Fireplace Heater DV36 NG/LPGThis Enviro DV36 Fireplace Specifications Installation OptionsFor Your Safety Read Before Operating InstructionsBlue, the fireplace is getting too much To Turn GAS Fireplace OFF Component Sound & ReasonMaintenance And Service Never Operate Fireplace with the glass Removed Bottom latches for glassKit Parts List Completely cooled downConversion Kit Installation Removing valve ScrewRing on valve screw Initial Installation Qualified Installers onlyDo not interfere with the structural integrity of the walls Mantel Clearances Vent Termination Restrictions Installation Instructions KIT ComponentsInstallation of Fireplace Horizontal Vent Kit Manufacturer Trade Name Nominal Sizes4DSC Two 2 piece wall Vent restrictor is located in the center Being Attached to Wood Assemble Vertical Vent TerminationRoof Pitch Minimum Height H Feet Meters Use of Wall Straps Installation of Electrical Wiring for the Optional FAN KIT GAS Line Connection To Test Valve PressuresSecondary Installation Empty firebox with grate and locator pinsThird Stage Log Set Installation Never operate the fireplace with the glass door removed Complete log set-up with embersTurn off the gas control knob and allow the unit to cool Back Panel In PlaceKit Contents Installation of Kit Hook Fan Tabs Over Grommets at Unit BackTrouble Shooting Problem Possible Cause SolutionParts List Reference Part Description Part NumberParts List Options Parts Diagram Warranty To the DealerTo the Distributor Installation Data Sheet