Maintenance And Service
Conversion Kit Installation:
1.Turn control knob on the gas valve to the “OFF” position and shut the gas supply off at the
2.Remove the glass as shown in the MAINTENANCE AND SERVICE - GLASS DOOR REMOVAL.
3.Carefully remove the log set and ember material if they are installed.
4.Remove the burner as shown in the MAINTENANCE AND SERVICE - BURNER REMOVAL.
5.Convert the burner orifice(s):
a)Remove the main burner orifice with a 1⁄2 inch deep socket.
b)Put a bead of
c)Install the new orifice(s) from the kit into the brass elbow.
6.Convert the pilot injector:
a)Pull the pilot hood straight up to access the pilot injector.
b)Using a 5/32” or 4 mm Allen key, remove the pilot injector.
c)Install the new pilot injector supplied with this conversion kit. Simply screw the new injector inside the pilot hood using the Allen key,
d)Reinstall the hood by placing the hood on the assembly, line up the key way, and snap into place.
7.Convert the SIT gas valve:
a)Remove the black protection cap from the HI/LO knob by hand shown in Figure 10.
Figure 11: Removing valve
screw.
b)Insert a 5/32” or 4 mm Allen wrench into the hexagonal
c)Check that the screw is clean and if necessary remove dirt.
d)Flip the screw (refer to Figure 12).
e)Using the Allen wrench as shown in Figure 11, rotate the screw clockwise until a torque of 9 inch lbs. WARNING! Do not over tighten the screw. It is recommended that you grip the wrench by the short side.
f)Verify that if the conversion is from NG to LPG, the screw must be
Figure 10: Removing
valve cap.
Figure 12: Flip valve
screw.
12