Enviro DV36 Turn off the gas control knob and allow the unit to cool, Back Panel In Place

Page 32

Secondary Installation

OPTIONAL CERAMIC BRICK PANEL INSTALLATION:

Figure 49. Back Panel In Place.

Turn off the gas control knob and allow the unit to cool.

Please ensure that your ceramic panels have not been damaged.

To Install Panels:

1.Remove the glass door by following the

instruction in the “SECONDARY INSTALLATION -

GLASS DOOR REMOVAl” section and remove logs if necessary.

2.Slide center brick panel up behind the baffle (shown in Figure 49) and rest the bottom of the panel on the ledge.

3.Using a flat head screwdriver, bend the top tabs on either side at the front of the baffle down (refer to Figure 51 for placement).

4.Slide the right panel along the side of the firebox until it is tight against the right side of the center panel. Ensure the panel is behind the top tab (see Figure 50).

5.Bend up the right bottom tab until it touches the bottom of the right panel (see Figure 52) and press the top right tab tight against the top of the panel (see

Figure 51).

6.Repeat steps 4 and 5 for the left panel.

7.Install the log set (refer to SECONDARY INSTALLATION - LOG SET

AND EMBER INSTALLATION) and glass door.

To Remove Panels:

1.Pull the bottom and top tabs away from the side panels.

2.Carefully slide the side panels out towards the front, do not slide the panels on the tabs.

3.Push the center panel straight up about 1⁄4 inch (5 mm), pull the bottom out past the ledge, then pull the panel down until it is past the bottom of the baffle. Remove panel from firebox

Figure 50. Right Panel In Place.

 

 

 

Figure 51. Top Tab For Right Panel.

 

Figure 52. Bottom Tab For Right Panel.

32

Image 32
Contents For Your Safety R E C T V E N T F I R E P L a C ESafety Precautions GeneralTable of Contents This Enviro DV36 Fireplace Codes And ApprovalsVented GAS Fireplace Heater DV36 NG/LPG Specifications Installation OptionsFor Your Safety Read Before Operating InstructionsBlue, the fireplace is getting too much To Turn GAS Fireplace OFF Component Sound & ReasonMaintenance And Service Never Operate Fireplace with the glass Removed Bottom latches for glassKit Parts List Completely cooled downConversion Kit Installation Removing valve ScrewRing on valve screw Initial Installation Qualified Installers onlyDo not interfere with the structural integrity of the walls Mantel Clearances Vent Termination Restrictions Installation Instructions KIT ComponentsInstallation of Fireplace Horizontal Vent Kit Manufacturer Trade Name Nominal Sizes4DSC Two 2 piece wall Vent restrictor is located in the center Being Attached to Wood Assemble Vertical Vent TerminationRoof Pitch Minimum Height H Feet Meters Use of Wall Straps Installation of Electrical Wiring for the Optional FAN KIT GAS Line Connection To Test Valve PressuresSecondary Installation Empty firebox with grate and locator pinsThird Stage Log Set Installation Never operate the fireplace with the glass door removed Complete log set-up with embersTurn off the gas control knob and allow the unit to cool Back Panel In PlaceKit Contents Installation of Kit Hook Fan Tabs Over Grommets at Unit BackTrouble Shooting Problem Possible Cause SolutionParts List Reference Part Description Part NumberParts List Options Parts Diagram To the Distributor WarrantyTo the Dealer Installation Data Sheet