Maintenance And Service
g)
Figure 13: O-ring on valve screw.
8.Reinstall the burner, brick panels, log set, embers, and glass door.
Also refer to SECONDARY INSTALLATION - INSTALLING LOG SET AND EMBERS
in your Owner’s Manual. When
Figure 14. Ignitor assembly
beside the burner.
9.Reconnect the main gas line if it was disconnected and open the
10.Use a small brush to apply a warm soapy water solution to all gas connections (use a half dish soap and half warm water). If a gas leak is present, bubbling will occur. Gas leaks can be repaired by using an approved pipe thread sealant or approved Teflon tape. NEVER USE AN OPEN FLAME WHEN TESTING FOR LEAKS.
11.Reconnect the electrical power to the unit.
12.Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition and operation and proper flame appearance. Also refer to SECONDARY INSTALLATION - INSTALLING LOG SET AND EMBERS in your Owner’s Manual for a flame appearance picture.
13.MAKE SURE that the conversion label is installed on or close to the rating label to signify that the unit has been converted to a different fuel type.
13