Avalon Stoves DVL Insert EF II owner manual Vent Connector Removal

Page 17

Installation (for qualified installers only)

17

Vent Connector Removal and Installation (continued)

Vent Connector Removal

Pull the vent connector rod forward.

WARNING: The anti-seize on the vent connector can stain clothing, carpets, or other items.

Slide the vent connector to the rear. It will "snap" out.

Vent Connector Installation

Attach the flex vent to the vent connector.

Slide the insert

into place, lining up these guides with the edges of the vent

connector

Push the vent connector rod in, lift slightly, and line it up so the tabs on the end of the rod engage the hooks on the vent connector

Pull on the vent connector rod until the vent connector snaps into place. Slide the vent connector rod in to conceal it.

© Travis Industries

4080123

100-01174_002

Image 17
Contents Travis Industries, Inc DVL Insert EFIntroduction Important Information 2IntroductionSave Your Bill of Sale 4080123Table of Contents If YOU Smell GAS Safety PrecautionsDo not place anything inside Heating Specifications Features Installation OptionsDimensions Natural Gas PropaneInstallation for qualified installers only Fireplace Requirements Top Convection DeflectorFactory-Built Metal Wood-Burning Fireplace Requirements Hearth RequirementsLeveling Bolts Mantel Clearances ClearancesFace Height Width Face SizingGas Inlet Pressure Gas Line RequirementsGas Line Location Altitude Considerations Vent RequirementsVent Restrictor Vent InstallationVent Location Vent Configurations Inlet & Exhaust Re-LineVent Connector Removal and Installation Vent Connector Removal Surround Panel Installation Installation Without Surround PanelsElectrical Connection Installation of the On/Off Switch and RheostatGlass Frame Removal and Installation Finalizing the InstallationGlass Install the logs Log Set InstallationInstalling the Rock Wool Install the twigs, ember chunk, kibbles, and rock woolPilot Flame Inspection Steps for Finalizing the InstallationAir Shutter Adjustment Fine Tuning the EMBER-FYRE Burner Location of Controls 26OperationBefore You Begin Starting The Pilot Flame Operation28Operation Adjusting the Flame HeightStarting the Heater for the First Time Turning the Heater On and OffOperation29 Adjusting the Blower SpeedNormal Operating Sounds Normal Operating OdorsMaintaining Your Heaters Appearance 30MaintenanceYearly Service Procedure Troubleshooting Table MaintenanceHow this Heater Works 32MaintenanceWhat Turns the Main Burners On and Off What Prevents Gas BuildupReplacement Parts List Maintenance33Wiring Diagram Safety Label Safety LabelYears 1 & 2 Coverage Parts & Labor Limited 7 Year WarrantyYears 3 Through 5 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyLP Conversion Instructions Burner ReplacementFollow the directions below to replace the orifices Optional Equipment for qualified installers onlyTo adjust the pilot flame, turn this screw Note if totally Firebacks Optional Equipment for qualified installers only Accent Light Important Installation Note for Models Using the FirebacksAccent Light Operation Lower Surround Panel Index

DVL Insert EF II specifications

The Avalon Stoves DVL Insert EF II is an impressive addition to any home, combining functionality, efficiency, and aesthetic appeal. Designed to convert traditional wood-burning fireplaces into an efficient heating source, the DVL Insert EF II stands out due to its exceptional engineering and innovative features.

One of the main characteristics of the DVL Insert EF II is its high-efficiency rating. With an impressive efficiency of up to 85%, this insert maximizes heat output while minimizing wood consumption. This translates to fewer trips to the woodpile, allowing homeowners to enjoy extended warmth and comfort during the cold months.

Key technologies incorporated into the DVL Insert EF II include a sophisticated air wash system that keeps the glass clean, ensuring a clear view of the captivating flames. This feature not only enhances the aesthetic appeal of the insert but also reduces the maintenance required to keep the glass sparkling. Additionally, the DVL Insert EF II employs a secondary combustion system that ensures more complete burning of the wood, which increases both efficiency and heat output while reducing smoke emissions.

The DVL Insert EF II comes with a robust firebox, made from high-quality steel, which is designed to withstand high temperatures and offer durability over time. Its large viewing area is framed by a cast-iron door, giving it a timeless and elegant appearance that complements various styles of decor. The insert is available in multiple finishes, allowing homeowners to choose a look that fits their personal style and existing interior.

Another notable feature is the built-in blower system, which helps distribute heat more evenly throughout the room, enhancing comfort. This option can be particularly beneficial in larger spaces, as it allows for better temperature regulation and extends the reach of the warmth generated.

Installation flexibility is also a key characteristic of the DVL Insert EF II. It can be fitted into most standard fireplaces, making it a versatile choice for many homes. Its compact design ensures that it can fit effortlessly into the existing structure while still providing powerful heating capabilities.

In summary, the Avalon Stoves DVL Insert EF II is a highly efficient, aesthetically pleasing option for homeowners looking to upgrade their fireplace capabilities. With advanced technologies such as an air wash system, secondary combustion, and a built-in blower, this insert delivers both convenience and performance, making it an excellent addition to any living space.