Avalon Stoves DVL Insert EF II owner manual Do not place anything inside

Page 5

Safety Precautions

Do not place clothing or other flammable items on or near the heater. Because this heater can be controlled by a thermostat there is a possibility of the heater turning on and igniting any items placed on or near it.

The viewing glass should be

 

opened only

for lighting the

 

pilot or conducting service. Do

 

not operate with cracked,

 

broken, or removed glass.

 

Any safety screen or guard

 

removed for servicing must be

 

replaced prior to operating the

 

heater.

 

 

Operate the heater according

 

to the instructions included in

 

this manual.

 

 

If the main burners do not start

 

correctly turn the gas off at the

 

gas control valve and call your

 

dealer for service.

 

This unit is not for use with

 

solid fuel

 

This

 

 

Do not place anything inside

Manual

the firebox (except the

 

included fiber

logs).

 

If the fiber logs become damaged, replace with Travis Industries log set.

Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be supervised when they are in the same room as the heater.

Instruct everyone in the house how to shut gas off to the appliance and at the gas main shutoff valve. The gas main shutoff valve is usually next to the gas meter or propane tank and requires a wrench to shut off.

5

Light the heater using the built- in piezo igniter. Do not use matches or any other external device to light your heater.

Allow the heater to cool before carrying out any maintenance or cleaning.

Never remove, replace, modify or substitute any part of the heater unless instructions are given in this manual. All other work must be done by a trained technician. Don't modify or replace orifices.

The pilot flame must contact the thermopile and thermocouple (see the illustration to the left). If it does not, turn the gas control valve to "OFF" and call your dealer.

Do not throw this manual away. This manual has important operating and maintenance instructions that you will need at a later time. Always follow the instructions in this manual.

Plug the heater into a 120V grounded electrical outlet. Do not remove the grounding plug.

Don’t route the electrical cord in front of, over, or under the heater

Travis Industries, Inc. grants no warranty, implied or stated, for the installation or maintenance of your heater, and assumes no responsibility of any consequential damage(s).

© Travis Industries

4080123

100-01174_002

Image 5
Contents Travis Industries, Inc DVL Insert EFIntroduction Important Information 2IntroductionSave Your Bill of Sale 4080123Table of Contents If YOU Smell GAS Safety PrecautionsDo not place anything inside Heating Specifications Features Installation OptionsDimensions Natural Gas PropaneInstallation for qualified installers only Fireplace Requirements Top Convection DeflectorFactory-Built Metal Wood-Burning Fireplace Requirements Hearth RequirementsLeveling Bolts Mantel Clearances ClearancesFace Height Width Face SizingGas Inlet Pressure Gas Line RequirementsGas Line Location Altitude Considerations Vent RequirementsVent Restrictor Vent InstallationVent Location Vent Configurations Inlet & Exhaust Re-LineVent Connector Removal and Installation Vent Connector Removal Surround Panel Installation Installation Without Surround PanelsElectrical Connection Installation of the On/Off Switch and RheostatGlass Frame Removal and Installation Finalizing the InstallationGlass Install the logs Log Set InstallationInstalling the Rock Wool Install the twigs, ember chunk, kibbles, and rock woolPilot Flame Inspection Steps for Finalizing the InstallationAir Shutter Adjustment Fine Tuning the EMBER-FYRE Burner Location of Controls 26OperationBefore You Begin Starting The Pilot Flame Operation28Operation Adjusting the Flame HeightStarting the Heater for the First Time Turning the Heater On and OffOperation29 Adjusting the Blower SpeedNormal Operating Sounds Normal Operating OdorsMaintaining Your Heaters Appearance 30MaintenanceYearly Service Procedure Troubleshooting Table MaintenanceHow this Heater Works 32MaintenanceWhat Turns the Main Burners On and Off What Prevents Gas BuildupReplacement Parts List Maintenance33Wiring Diagram Safety Label Safety LabelYears 1 & 2 Coverage Parts & Labor Limited 7 Year WarrantyYears 3 Through 5 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyLP Conversion Instructions Burner ReplacementFollow the directions below to replace the orifices Optional Equipment for qualified installers onlyTo adjust the pilot flame, turn this screw Note if totally Firebacks Optional Equipment for qualified installers only Accent Light Important Installation Note for Models Using the FirebacksAccent Light Operation Lower Surround Panel Index

DVL Insert EF II specifications

The Avalon Stoves DVL Insert EF II is an impressive addition to any home, combining functionality, efficiency, and aesthetic appeal. Designed to convert traditional wood-burning fireplaces into an efficient heating source, the DVL Insert EF II stands out due to its exceptional engineering and innovative features.

One of the main characteristics of the DVL Insert EF II is its high-efficiency rating. With an impressive efficiency of up to 85%, this insert maximizes heat output while minimizing wood consumption. This translates to fewer trips to the woodpile, allowing homeowners to enjoy extended warmth and comfort during the cold months.

Key technologies incorporated into the DVL Insert EF II include a sophisticated air wash system that keeps the glass clean, ensuring a clear view of the captivating flames. This feature not only enhances the aesthetic appeal of the insert but also reduces the maintenance required to keep the glass sparkling. Additionally, the DVL Insert EF II employs a secondary combustion system that ensures more complete burning of the wood, which increases both efficiency and heat output while reducing smoke emissions.

The DVL Insert EF II comes with a robust firebox, made from high-quality steel, which is designed to withstand high temperatures and offer durability over time. Its large viewing area is framed by a cast-iron door, giving it a timeless and elegant appearance that complements various styles of decor. The insert is available in multiple finishes, allowing homeowners to choose a look that fits their personal style and existing interior.

Another notable feature is the built-in blower system, which helps distribute heat more evenly throughout the room, enhancing comfort. This option can be particularly beneficial in larger spaces, as it allows for better temperature regulation and extends the reach of the warmth generated.

Installation flexibility is also a key characteristic of the DVL Insert EF II. It can be fitted into most standard fireplaces, making it a versatile choice for many homes. Its compact design ensures that it can fit effortlessly into the existing structure while still providing powerful heating capabilities.

In summary, the Avalon Stoves DVL Insert EF II is a highly efficient, aesthetically pleasing option for homeowners looking to upgrade their fireplace capabilities. With advanced technologies such as an air wash system, secondary combustion, and a built-in blower, this insert delivers both convenience and performance, making it an excellent addition to any living space.