Avalon Stoves DVL Insert EF II owner manual Operation, Starting The Pilot Flame

Page 27

Operation

Starting The Pilot Flame

The pilot flame is required to ignite the

main burners (it also plays a safety role). It a should be left on once lit. It will stay lit

unless the gas control valve is turned to "OFF". However, the pilot will go out if the gas is shut off, the propane tank runs out (or low) or if the stove malfunctions. If the pilot turns off frequently, call your dealer for information. To start the pilot follow the directions below:

27

5 minutes

WARNING:

b

When lighting or re-lighting the pilot, the glass must be removed (see page 20).

aRemove the glass (see page 20 for details).

b

Push the gas control knob in slightly and

 

 

turn it to the "OFF" position. The knob

c

 

will not turn from "ON" to "OFF" unless the

 

 

knob is depressed slightly. Wait five

 

 

minutes to let any gas that may have

 

 

accumulated inside the firebox escape.

 

 

If you smell leaking gas, follow the

 

 

directions on the cover "IF YOU SMELL

 

 

GAS".

 

c

Turn the gas control knob to the "PILOT"

d

 

position and press the knob in, this will

 

 

allow gas to flow to the pilot light. Press

 

 

the button on the pilot igniter repeatedly

 

 

until you see the pilot light.

 

WARNING:

 

If the pilot does not light after 15 seconds,

 

release the knob and call your dealer for

e

service. Do not attempt to light pilot until

 

service has been performed.

 

NOTE:

 

You may wish to remove the log set to gain

 

a better view of the pilot (see page 22).

 

d

Keep the gas control knob depressed for

f

 

30 seconds once it is lit.

e

Release the gas control knob. If the pilot

 

 

goes out, repeat step C. If the pilot

 

 

refuses to stay lit, call your dealer for

 

 

service. With the pilot lit, proceed to step

 

 

“f”.

 

f

Replace the glass.

g

g

Turn the gas control knob counter-

 

 

clockwise to "ON". The pilot is now lit

 

 

and the heater can be turned on and off.

 

PILOT

IGNITER

30 seconds

?

© Travis Industries

4080123

100-01174_002

Image 27
Contents Travis Industries, Inc DVL Insert EF4080123 2IntroductionIntroduction Important Information Save Your Bill of SaleTable of Contents If YOU Smell GAS Safety PrecautionsDo not place anything inside Natural Gas Propane Features Installation OptionsHeating Specifications DimensionsInstallation for qualified installers only Fireplace Requirements Top Convection DeflectorHearth Requirements Leveling BoltsFactory-Built Metal Wood-Burning Fireplace Requirements Mantel Clearances ClearancesFace Height Width Face SizingGas Line Requirements Gas Line LocationGas Inlet Pressure Altitude Considerations Vent RequirementsVent Restrictor Vent InstallationVent Location Vent Configurations Inlet & Exhaust Re-LineVent Connector Removal and Installation Vent Connector Removal Surround Panel Installation Installation Without Surround PanelsElectrical Connection Installation of the On/Off Switch and RheostatGlass Frame Removal and Installation Finalizing the InstallationGlass Install the logs Log Set InstallationInstalling the Rock Wool Install the twigs, ember chunk, kibbles, and rock woolSteps for Finalizing the Installation Air Shutter AdjustmentPilot Flame Inspection Fine Tuning the EMBER-FYRE Burner 26Operation Before You BeginLocation of Controls Starting The Pilot Flame OperationTurning the Heater On and Off Adjusting the Flame Height28Operation Starting the Heater for the First TimeNormal Operating Odors Adjusting the Blower SpeedOperation29 Normal Operating Sounds30Maintenance Yearly Service ProcedureMaintaining Your Heaters Appearance Troubleshooting Table MaintenanceWhat Prevents Gas Buildup 32MaintenanceHow this Heater Works What Turns the Main Burners On and OffMaintenance33 Wiring DiagramReplacement Parts List Safety Label Safety LabelYears 6 & 7 Coverage Parts only Limited 7 Year WarrantyYears 1 & 2 Coverage Parts & Labor Years 3 Through 5 Coverage Parts & LaborLP Conversion Instructions Burner ReplacementFollow the directions below to replace the orifices Optional Equipment for qualified installers onlyTo adjust the pilot flame, turn this screw Note if totally Firebacks Optional Equipment for qualified installers only Accent Light Important Installation Note for Models Using the FirebacksAccent Light Operation Lower Surround Panel Index

DVL Insert EF II specifications

The Avalon Stoves DVL Insert EF II is an impressive addition to any home, combining functionality, efficiency, and aesthetic appeal. Designed to convert traditional wood-burning fireplaces into an efficient heating source, the DVL Insert EF II stands out due to its exceptional engineering and innovative features.

One of the main characteristics of the DVL Insert EF II is its high-efficiency rating. With an impressive efficiency of up to 85%, this insert maximizes heat output while minimizing wood consumption. This translates to fewer trips to the woodpile, allowing homeowners to enjoy extended warmth and comfort during the cold months.

Key technologies incorporated into the DVL Insert EF II include a sophisticated air wash system that keeps the glass clean, ensuring a clear view of the captivating flames. This feature not only enhances the aesthetic appeal of the insert but also reduces the maintenance required to keep the glass sparkling. Additionally, the DVL Insert EF II employs a secondary combustion system that ensures more complete burning of the wood, which increases both efficiency and heat output while reducing smoke emissions.

The DVL Insert EF II comes with a robust firebox, made from high-quality steel, which is designed to withstand high temperatures and offer durability over time. Its large viewing area is framed by a cast-iron door, giving it a timeless and elegant appearance that complements various styles of decor. The insert is available in multiple finishes, allowing homeowners to choose a look that fits their personal style and existing interior.

Another notable feature is the built-in blower system, which helps distribute heat more evenly throughout the room, enhancing comfort. This option can be particularly beneficial in larger spaces, as it allows for better temperature regulation and extends the reach of the warmth generated.

Installation flexibility is also a key characteristic of the DVL Insert EF II. It can be fitted into most standard fireplaces, making it a versatile choice for many homes. Its compact design ensures that it can fit effortlessly into the existing structure while still providing powerful heating capabilities.

In summary, the Avalon Stoves DVL Insert EF II is a highly efficient, aesthetically pleasing option for homeowners looking to upgrade their fireplace capabilities. With advanced technologies such as an air wash system, secondary combustion, and a built-in blower, this insert delivers both convenience and performance, making it an excellent addition to any living space.