Avalon Stoves DVL Insert EF II owner manual Hearth Requirements, Leveling Bolts

Page 9

Installation (for qualified installers only)

9

Factory-Built (Metal) Wood-Burning Fireplace Requirements

N O T E : Any parts that are removed must be removed in a way that would allow them to be re-installed if the insert is ever removed.

The damper ("A") and grate (with log set) ("B") must be removed (see the illustration below)

The smoke shelf ("C"), internal baffles ("D"), screen ("E"), masonry lining or refractory ("G" & "I"), and metal or glass doors ("F") may be removed (if applicable)

The fireplace must be permanently marked to indicate that it has been altered and is no longer suitable for burning solid fuel (wood), unless the removed parts are re-installed. Cutting of any sheet metal parts is prohibited (removal of rivets or screws F is acceptable).

The insulation ("H"), and any structured rigid frame members must not be removed or altered (side and top of door frame, side and top of the face of the fireplace, metal sides, etc.).

The metal floor ("J") may be removed to allow additional room for installation of the insert. If the floor is removed the insert must be placed directly on the metal base of the metal fireplace

 

H

 

A

 

C

 

D

E

I

 

B

 

G

 

J

Hearth Requirements

The heater and face must not contact combustible surfaces. A non-combustible hearth extension is not required. However, if the heater is installed next to the floor, we recommend a hearth to protect the flooring surface from discoloration or other negative impact from the heater.

Leveling Bolts

This heater includes front and rear leveling bolts to accommodate fireplaces with a step- down firebox.

NOTE: To access the rear leveling bolts, remove the burner (see page 39).

To access the rear leveling bolts remove these access plates (replace access plate and gasket after adjustment).

Use a 1/2” socket wrench (with extension) to adjust the leveling bolts.

Rear Leveling Bolt

Front Leveling Bolts

© Travis Industries

4080123

100-01174_002

Image 9
Contents Travis Industries, Inc DVL Insert EFIntroduction Important Information 2IntroductionSave Your Bill of Sale 4080123Table of Contents If YOU Smell GAS Safety PrecautionsDo not place anything inside Heating Specifications Features Installation OptionsDimensions Natural Gas PropaneInstallation for qualified installers only Fireplace Requirements Top Convection DeflectorHearth Requirements Leveling BoltsFactory-Built Metal Wood-Burning Fireplace Requirements Mantel Clearances ClearancesFace Height Width Face SizingGas Line Requirements Gas Line LocationGas Inlet Pressure Altitude Considerations Vent RequirementsVent Restrictor Vent InstallationVent Location Vent Configurations Inlet & Exhaust Re-LineVent Connector Removal and Installation Vent Connector Removal Surround Panel Installation Installation Without Surround PanelsElectrical Connection Installation of the On/Off Switch and RheostatGlass Frame Removal and Installation Finalizing the InstallationGlass Install the logs Log Set InstallationInstalling the Rock Wool Install the twigs, ember chunk, kibbles, and rock woolSteps for Finalizing the Installation Air Shutter AdjustmentPilot Flame Inspection Fine Tuning the EMBER-FYRE Burner 26Operation Before You BeginLocation of Controls Starting The Pilot Flame Operation28Operation Adjusting the Flame HeightStarting the Heater for the First Time Turning the Heater On and OffOperation29 Adjusting the Blower SpeedNormal Operating Sounds Normal Operating Odors30Maintenance Yearly Service ProcedureMaintaining Your Heaters Appearance Troubleshooting Table MaintenanceHow this Heater Works 32MaintenanceWhat Turns the Main Burners On and Off What Prevents Gas BuildupMaintenance33 Wiring DiagramReplacement Parts List Safety Label Safety LabelYears 1 & 2 Coverage Parts & Labor Limited 7 Year WarrantyYears 3 Through 5 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyLP Conversion Instructions Burner ReplacementFollow the directions below to replace the orifices Optional Equipment for qualified installers onlyTo adjust the pilot flame, turn this screw Note if totally Firebacks Optional Equipment for qualified installers only Accent Light Important Installation Note for Models Using the FirebacksAccent Light Operation Lower Surround Panel Index

DVL Insert EF II specifications

The Avalon Stoves DVL Insert EF II is an impressive addition to any home, combining functionality, efficiency, and aesthetic appeal. Designed to convert traditional wood-burning fireplaces into an efficient heating source, the DVL Insert EF II stands out due to its exceptional engineering and innovative features.

One of the main characteristics of the DVL Insert EF II is its high-efficiency rating. With an impressive efficiency of up to 85%, this insert maximizes heat output while minimizing wood consumption. This translates to fewer trips to the woodpile, allowing homeowners to enjoy extended warmth and comfort during the cold months.

Key technologies incorporated into the DVL Insert EF II include a sophisticated air wash system that keeps the glass clean, ensuring a clear view of the captivating flames. This feature not only enhances the aesthetic appeal of the insert but also reduces the maintenance required to keep the glass sparkling. Additionally, the DVL Insert EF II employs a secondary combustion system that ensures more complete burning of the wood, which increases both efficiency and heat output while reducing smoke emissions.

The DVL Insert EF II comes with a robust firebox, made from high-quality steel, which is designed to withstand high temperatures and offer durability over time. Its large viewing area is framed by a cast-iron door, giving it a timeless and elegant appearance that complements various styles of decor. The insert is available in multiple finishes, allowing homeowners to choose a look that fits their personal style and existing interior.

Another notable feature is the built-in blower system, which helps distribute heat more evenly throughout the room, enhancing comfort. This option can be particularly beneficial in larger spaces, as it allows for better temperature regulation and extends the reach of the warmth generated.

Installation flexibility is also a key characteristic of the DVL Insert EF II. It can be fitted into most standard fireplaces, making it a versatile choice for many homes. Its compact design ensures that it can fit effortlessly into the existing structure while still providing powerful heating capabilities.

In summary, the Avalon Stoves DVL Insert EF II is a highly efficient, aesthetically pleasing option for homeowners looking to upgrade their fireplace capabilities. With advanced technologies such as an air wash system, secondary combustion, and a built-in blower, this insert delivers both convenience and performance, making it an excellent addition to any living space.