Avalon Stoves DVL Insert EF II owner manual 26Operation, Before You Begin, Location of Controls

Page 26

26Operation

Before You Begin

Read this entire manual before you use your new heater (especially the section "Safety Precautions" on pages 4 & 5). Failure to follow the instructions may result in property damage, bodily injury, or even death.

Location of Controls

The Pilot Flame can be

found below the back log.

OFF

Blower Knob is

HI

LO

located either on the

upper right of the

 

 

surround panels or

 

behind the access panel

An instruction card for

 

operating the fireplace is

Open the

access door

attached to the inside of the

to view the

fireplace here. Replace it for

controls.

 

easy reference.

 

Gas Control Valve

Gas Control Knob Flame Adjust Knob

PILOT

IGNITER

PIlot Igniter

is located under this plate. It can only be

accessed with the glass removed.

N

O

OFF

ON/OFF Switch is

located either on

the upper right of

the surround panels

or behind the

access panel

Blower Knob

This knob controls the speed of the internal convection blower that

 

pushes the heated air into the room.

 

On/Off Switch

This control is used to turn the heater on and off.

Pilot Igniter

The pilot igniter is used only to start the pilot.

When pressed, it sends an

 

electrical charge to the pilot assembly. This creates a blue spark

 

directly next to the pilot, igniting the pilot flame.

Gas Control Knob

This knob is used to control gas to the heater and for starting the pilot.

 

There are three positions, ON, OFF, & PILOT. The pointer to the left of

 

the knob indicates the position this knob is in.

 

Flame Adjust Knob

This knob controls the flame height from low ("LO") to high ("HI"). The

 

pointer above the knob points to the position this knob is in.

 

 

 

© Travis Industries

4080123

100-01174_002

Image 26
Contents DVL Insert EF Travis Industries, IncSave Your Bill of Sale 2IntroductionIntroduction Important Information 4080123Table of Contents Safety Precautions If YOU Smell GASDo not place anything inside Dimensions Features Installation OptionsHeating Specifications Natural Gas PropaneInstallation for qualified installers only Top Convection Deflector Fireplace RequirementsFactory-Built Metal Wood-Burning Fireplace Requirements Hearth RequirementsLeveling Bolts Clearances Mantel ClearancesFace Sizing Face Height WidthGas Inlet Pressure Gas Line RequirementsGas Line Location Vent Requirements Altitude ConsiderationsVent Installation Vent RestrictorVent Configurations Inlet & Exhaust Re-Line Vent LocationVent Connector Removal and Installation Vent Connector Removal Installation Without Surround Panels Surround Panel InstallationInstallation of the On/Off Switch and Rheostat Electrical ConnectionFinalizing the Installation Glass Frame Removal and InstallationGlass Log Set Installation Install the logsInstall the twigs, ember chunk, kibbles, and rock wool Installing the Rock WoolPilot Flame Inspection Steps for Finalizing the InstallationAir Shutter Adjustment Fine Tuning the EMBER-FYRE Burner Location of Controls 26OperationBefore You Begin Operation Starting The Pilot FlameStarting the Heater for the First Time Adjusting the Flame Height28Operation Turning the Heater On and OffNormal Operating Sounds Adjusting the Blower SpeedOperation29 Normal Operating OdorsMaintaining Your Heaters Appearance 30MaintenanceYearly Service Procedure Maintenance Troubleshooting TableWhat Turns the Main Burners On and Off 32MaintenanceHow this Heater Works What Prevents Gas BuildupReplacement Parts List Maintenance33Wiring Diagram Safety Label Safety LabelYears 3 Through 5 Coverage Parts & Labor Limited 7 Year WarrantyYears 1 & 2 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyBurner Replacement LP Conversion InstructionsOptional Equipment for qualified installers only Follow the directions below to replace the orificesTo adjust the pilot flame, turn this screw Note if totally Firebacks Optional Equipment for qualified installers only Important Installation Note for Models Using the Firebacks Accent LightAccent Light Operation Lower Surround Panel Index

DVL Insert EF II specifications

The Avalon Stoves DVL Insert EF II is an impressive addition to any home, combining functionality, efficiency, and aesthetic appeal. Designed to convert traditional wood-burning fireplaces into an efficient heating source, the DVL Insert EF II stands out due to its exceptional engineering and innovative features.

One of the main characteristics of the DVL Insert EF II is its high-efficiency rating. With an impressive efficiency of up to 85%, this insert maximizes heat output while minimizing wood consumption. This translates to fewer trips to the woodpile, allowing homeowners to enjoy extended warmth and comfort during the cold months.

Key technologies incorporated into the DVL Insert EF II include a sophisticated air wash system that keeps the glass clean, ensuring a clear view of the captivating flames. This feature not only enhances the aesthetic appeal of the insert but also reduces the maintenance required to keep the glass sparkling. Additionally, the DVL Insert EF II employs a secondary combustion system that ensures more complete burning of the wood, which increases both efficiency and heat output while reducing smoke emissions.

The DVL Insert EF II comes with a robust firebox, made from high-quality steel, which is designed to withstand high temperatures and offer durability over time. Its large viewing area is framed by a cast-iron door, giving it a timeless and elegant appearance that complements various styles of decor. The insert is available in multiple finishes, allowing homeowners to choose a look that fits their personal style and existing interior.

Another notable feature is the built-in blower system, which helps distribute heat more evenly throughout the room, enhancing comfort. This option can be particularly beneficial in larger spaces, as it allows for better temperature regulation and extends the reach of the warmth generated.

Installation flexibility is also a key characteristic of the DVL Insert EF II. It can be fitted into most standard fireplaces, making it a versatile choice for many homes. Its compact design ensures that it can fit effortlessly into the existing structure while still providing powerful heating capabilities.

In summary, the Avalon Stoves DVL Insert EF II is a highly efficient, aesthetically pleasing option for homeowners looking to upgrade their fireplace capabilities. With advanced technologies such as an air wash system, secondary combustion, and a built-in blower, this insert delivers both convenience and performance, making it an excellent addition to any living space.