Avalon Stoves DVL Insert EF II Steps for Finalizing the Installation, Pilot Flame Inspection

Page 24

24

Finalizing the Installation

Steps for Finalizing the Installation

1.Remove the glass (see page 20).

NOTE: If using propane (LP) convert the appliance prior to installing the logs.

2.We recommend you purge the gas line at this time (with the glass removed). This allows gas to be detected once it enters the firebox, ensuring gas does not build up.

3.Turn on gas to the heater. Leak test all gas joints prior to starting the appliance. Start the pilot. Start the main burner. Leak test all gas joints again.

4.Check the pilot flame following the directions below.

Pilot Flame Inspection

The pilot flame should look like the illustration below. Adjust the pilot flame if necessary.

To adjust the pilot flame, turn this screw. Clockwise

The pilot flame must contact the thermocouple and

 

lowers the flame while counter-clockwise raises it.

thermopile (see the illustration below). Adjust the pilot up or

 

Standard

down as necessary.

Screwdriver

 

5.Install the logs (see page 22).

6.Replace the glass.

7.Check the air shutter following the directions below.

Air Shutter Adjustment

Let the heater burn for fifteen minutes (make sure the logs and glass are in place. The flames should look like the illustration below. Adjust the air shutter, if necessary, to achieve the correct looking flame.

There are two air shutters on this fireplace - adjust both air shutters to obtain the correct flame.

Move the controls left or right until the flame

Front Air Shutter

Rear Air

looks correct. The rear air shutter affects the rear portion of the burner, the front air shutter the front portion of the burner.

Pushing to the right gives the flame more air, making it more blue. Pushing to the left gives the flame less air, making it more orange.

NOTE: If the air control is all the way open, yet the flames remain sooty, shut off gas to the fireplace and contact a qualified gas service technician.

Control

Shutter Control

NOTE: The logs must be installed correctly to monitor the flame while adjusting the air shutter.

Correct

Not Enough Air

Too Much Air

Flames should be blue at the base, yellow-orange on the top.

If the flames are over 14" tall or sooty on the ends, open the air shutter.

If the flames are all blue and short, close the air shutter.

© Travis Industries

4080123

100-01174_002

Image 24
Contents DVL Insert EF Travis Industries, Inc2Introduction Introduction Important InformationSave Your Bill of Sale 4080123Table of Contents Safety Precautions If YOU Smell GASDo not place anything inside Features Installation Options Heating SpecificationsDimensions Natural Gas PropaneInstallation for qualified installers only Top Convection Deflector Fireplace RequirementsHearth Requirements Leveling BoltsFactory-Built Metal Wood-Burning Fireplace Requirements Clearances Mantel ClearancesFace Sizing Face Height WidthGas Line Requirements Gas Line LocationGas Inlet Pressure Vent Requirements Altitude ConsiderationsVent Installation Vent RestrictorVent Configurations Inlet & Exhaust Re-Line Vent LocationVent Connector Removal and Installation Vent Connector Removal Installation Without Surround Panels Surround Panel InstallationInstallation of the On/Off Switch and Rheostat Electrical ConnectionFinalizing the Installation Glass Frame Removal and InstallationGlass Log Set Installation Install the logsInstall the twigs, ember chunk, kibbles, and rock wool Installing the Rock WoolSteps for Finalizing the Installation Air Shutter AdjustmentPilot Flame Inspection Fine Tuning the EMBER-FYRE Burner 26Operation Before You BeginLocation of Controls Operation Starting The Pilot FlameAdjusting the Flame Height 28OperationStarting the Heater for the First Time Turning the Heater On and OffAdjusting the Blower Speed Operation29Normal Operating Sounds Normal Operating Odors30Maintenance Yearly Service ProcedureMaintaining Your Heaters Appearance Maintenance Troubleshooting Table32Maintenance How this Heater WorksWhat Turns the Main Burners On and Off What Prevents Gas BuildupMaintenance33 Wiring DiagramReplacement Parts List Safety Label Safety LabelLimited 7 Year Warranty Years 1 & 2 Coverage Parts & LaborYears 3 Through 5 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyBurner Replacement LP Conversion InstructionsOptional Equipment for qualified installers only Follow the directions below to replace the orificesTo adjust the pilot flame, turn this screw Note if totally Firebacks Optional Equipment for qualified installers only Important Installation Note for Models Using the Firebacks Accent LightAccent Light Operation Lower Surround Panel Index

DVL Insert EF II specifications

The Avalon Stoves DVL Insert EF II is an impressive addition to any home, combining functionality, efficiency, and aesthetic appeal. Designed to convert traditional wood-burning fireplaces into an efficient heating source, the DVL Insert EF II stands out due to its exceptional engineering and innovative features.

One of the main characteristics of the DVL Insert EF II is its high-efficiency rating. With an impressive efficiency of up to 85%, this insert maximizes heat output while minimizing wood consumption. This translates to fewer trips to the woodpile, allowing homeowners to enjoy extended warmth and comfort during the cold months.

Key technologies incorporated into the DVL Insert EF II include a sophisticated air wash system that keeps the glass clean, ensuring a clear view of the captivating flames. This feature not only enhances the aesthetic appeal of the insert but also reduces the maintenance required to keep the glass sparkling. Additionally, the DVL Insert EF II employs a secondary combustion system that ensures more complete burning of the wood, which increases both efficiency and heat output while reducing smoke emissions.

The DVL Insert EF II comes with a robust firebox, made from high-quality steel, which is designed to withstand high temperatures and offer durability over time. Its large viewing area is framed by a cast-iron door, giving it a timeless and elegant appearance that complements various styles of decor. The insert is available in multiple finishes, allowing homeowners to choose a look that fits their personal style and existing interior.

Another notable feature is the built-in blower system, which helps distribute heat more evenly throughout the room, enhancing comfort. This option can be particularly beneficial in larger spaces, as it allows for better temperature regulation and extends the reach of the warmth generated.

Installation flexibility is also a key characteristic of the DVL Insert EF II. It can be fitted into most standard fireplaces, making it a versatile choice for many homes. Its compact design ensures that it can fit effortlessly into the existing structure while still providing powerful heating capabilities.

In summary, the Avalon Stoves DVL Insert EF II is a highly efficient, aesthetically pleasing option for homeowners looking to upgrade their fireplace capabilities. With advanced technologies such as an air wash system, secondary combustion, and a built-in blower, this insert delivers both convenience and performance, making it an excellent addition to any living space.