Regency U39-NG, U39-LP installation manual Table of Contents

Page 3

Page

Safety Label

 

Safety Labels

4

Installation

 

Specifications

5

Information for Mobile/Manufactured Home

 

After First Sale

5

Before You Start

5

General Safety Information

6

Installation Checklist

6

Clearances to Combustibles

6

Manufactured Mobile Home Requirements

7

Locating Your ULTIMATE Gas Stove

7

Louver Installation

7

Combustion and Ventilation Air

7

Venting

7

Installation Precautions

7

Exterior Vent Terminal Locations

8

Rigid Pipe Venting Components List

9

Rigid Pipe Venting Systems

 

Horizontal or Vertical Terminatioins

10

Safety Precautions for the Installer

11

Venting Arrangements - Horizontal

 

Terminations: All Systems

11

Venting Arrangements - Vertical Terminations

11

- Straight Vertical

11

- Offset Vertical

11

Vent Restrictor Position

11

Horizontal and Vertical Venting With Two Elbows

12

DV Stove Horizontal Vent Kit

13

Dura-Vent Termination Kits

15

Planning Your Dura-Vent Installation

15

Dura-Vent Venting Components Parts List

15

Dura-Vent Horizontal Installation

16

Dura-Vent Vertical Termination Installation

17

Offset Chart

18

Cathedral Ceiling Installations

18

Support Extension - Round or Square

19

Converting a Class-A Metal Chimney or Masonry

 

Chimney to a Direct Vent System

19

- Instructions for Converting a Factory Built

 

Metal Chimney

19

- Instructions for Converting a Masonry Chimney ...

20

TABLE OF CONTENTS

 

Page

System Data Chart

21

Gas Connection

21

High Elevation

21

Conversion from Natural Gas to Propane

22

Conversion to Lower BTU

23

Gas Pipe Pressure Testing

23

Valve Description

23

Aeration Adjustment

24

Log Installation

24

Front Door Installation

25

Wiring Diagram

26

Optional Wall Thermostat

26

Optional Remote Control Installation

26

Final Check

27

Operating Instructions

 

Operating Instructions

27

Lighting Procedure

27

Shutdown Procedure

27

First Fire

27

Convection Fan Operation

28

Copy of Lighting Plate Instructions

28

Adjusting Flame Height

28

Normal Operating Sounds of Gas Appliances

28

Maintenance

 

Maintenance Instructions

29

General Vent Maintenance

29

Gold Plated Doors

29

Log Replacement

30

Door Gasket

30

Latch Adjustment

30

Glass Replacement

30

Fan Maintenance

31

Removing Valve

32

Replacement Parts List

33

Warranty

 

Warranty

39

Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove

3

Image 3
Contents Ultimate U39 Regency Unit SpecificationsTable of Contents Copy of Safety Label for U39 Gas Stove Safety LabelInformation for Mobile InstallationSpecifications Save These InstructionsGeneral Safety Information Installation ChecklistClearances to Combustibles Locating Your Ultimate GAS Stove Louver InstallationInstallation Precautions Venting IntroductionExterior Vent Terminal 4DT-AJB Rigid Pipe Venting Components ListAlternate Horizontal Termination Caps Rigid Pipe Venting SystemsVent Restrictor Position Safety Precautions for the InstallerRigid Pipe Venting Arrangements Horizontal Terminations for All Venting SystemsVertical Venting with Two 2 90o Elbows Horizontal Venting with Two 2 90o ElbowsSions on pages 8 to DV Stove Horizontal Vent KITQty. Description OptionalBrick, concrete, or other types of sidings Dismantle all pipe sections including vent terminalDURA-VENT Venting Components Planning Your Dura-Vent InstallationMinimum components for a Dura-Vent Horizontal Installation DURA-VENT Termination KITSnorkel Terminations DURA-VENT Horizontal InstallationsBelow Grade Installation Cathedral Ceilings Offset ChartSupport Extensions Round Rdse or Square Sqse GeneralConverting a Factory Built Metal Chimney Converting a Masonry Chimney System Data GAS ConnectionHigh Elevation System Data U39 with 40,000 BTUConversion from Natural GAS to Propane Pilot assembly is now accessible for stepsGAS Pipe Pressure Testing Conversion to Lower BTU RatingValve Description U39 with 30,000 Btu/h Aeration AdjustmentLOG SET Installation U39 with 38,000 Btu/hPackaged separately Front Door InstallationWiring Optional Remote ControlOptional Wall Thermostat Operating Instructions Copy of the Lighting Plate instructions Adjusting Flame HeightNormal Operating Sounds GAS Appliances Automatic Convection FAN OperationGOLD-PLATED Doors MaintenanceMaintenance Instructions General Vent MaintenanceDoor Gasket LOG ReplacementLatch Adjustment Glass ReplacementReplacing U39 Fan FAN MaintenanceAlternate Fan Access To remove U39 fanRemoving Valve Parts List U39 Main AssemblyDescription U39 Burner & LOG Assembly U39 Door Assemblies Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

U39-NG, U39-LP specifications

The Regency U39-LP and U39-NG are modern gas fireplaces designed to enhance the aesthetic appeal and functionality of any space while delivering exceptional performance. These units are part of Regency's commitment to innovation and sustainability, providing homeowners with an efficient heating solution that seamlessly integrates into various home styles.

One of the standout features of the U39 series is its versatility in fuel options. The U39-LP operates on liquid propane, while the U39-NG utilizes natural gas. This flexibility allows homeowners to choose the best option suited for their existing infrastructure and personal preferences. Both models are designed to deliver efficient heating with an impressive BTU output, ensuring that rooms stay warm and comfortable during colder months.

The U39 series is equipped with cutting-edge technologies, including a state-of-the-art control system that allows users to easily adjust the flame height and heat output. This feature not only enhances user convenience but also promotes energy efficiency by allowing adjustments based on real-time heating needs. The inclusion of an optional remote control further simplifies the operation, enabling users to manage their fireplace from anywhere in the room.

Another remarkable aspect of the Regency U39-LP and U39-NG is the clean, contemporary design. The linear shape and large viewing area provide an unobstructed view of the flames, adding a stunning focal point to any living space. The customizable options for finishes and surround materials mean that homeowners can tailor the fireplace to perfectly match their décor, whether it be modern, traditional, or somewhere in between.

Safety is a top priority for Regency, and the U39 series includes multiple safety features to ensure peace of mind. An integrated safety shut-off system is designed to automatically turn off the unit in case of emergencies, while tempered glass doors protect against accidental burns.

In summary, the Regency U39-LP and U39-NG gas fireplaces embody a blend of functionality, beauty, and safety. With their high thermal efficiency, user-friendly technologies, and elegant design, these fireplaces are an ideal choice for anyone looking to elevate their home heating experience while enjoying the charm of a glowing fire. Whether it's for a cozy gathering with family or a quiet evening alone, the U39 series stands out as a stylish solution with exceptional performance.