Regency U39-NG, U39-LP Rigid Pipe Venting Arrangements, Safety Precautions for the Installer

Page 11

INSTALLATION

Vent or Fireplace Products Interna- tional Ltd.

RIGID PIPE VENTING ARRANGEMENTS

4)Installation other than as instructed by Simpson Dura-Vent and Fireplace Prod- ucts International Ltd.

Warning: Always maintain re- quired clearances (air spaces) to nearby combustibles to pre- vent a fire hazard. Do not fill air spaces with insulation.

Be sure to check the vent termination clearance requirements from decks, win- dows, soffits, gas regulators, air supply inlets and public walkways as specified in the Exterior Vent Terminal Locations on page 8 and in your local building codes.

The gas appliance and vent system must be vented directly to the out- side of the building, and never be attached to a chimney serving a sep- arate solid fuel or gas-burning appli-

ance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.

SAFETY

PRECAUTIONS FOR THE INSTALLER

1)Wear gloves and safety glasses for protection.

2)Exercise extreme caution when using ladders or on roof tops.

3)Be aware of electrical wiring lo- cations in walls and ceilings.

Horizontal Terminations for All Venting Systems

The shaded areas in the diagram below show all allowable combinations of verti- cal runs with horizontal terminations. Maximum one 90O elbow (two 45o elbows equal one 90o elbow).

Propane and Natural Gas:

Residential, Manufactured and

Mobile Homes Installations

The venting arrangements diagrammed below, have a min. of 75% (flue loss) efficiency with Fan Off, as required for manufactured homes. (Actual efficiency may be as high as 85%)

May be installed in Manufactured (Mobile)

Homes after first sale.

Vertical Termination Systems for Residential Manufactured and Mobile Homes

The shaded area in the diagram below shows all allowable combinations of straight verti- cal and offset to vertical runs with vertical terminations. Maximum two 45o elbows.

If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles.

May be installed in Manufactured (Mobile)

Homes after first sale.

Vent Restrictor Position

To set the Vent restriction as indi- cated in the diagram, simply loosen the screws and push the vent restrictor plate to the correct posi- tion. Tighten the screws.

Vent Restrictor setting at

Vent Restrictor setting at

38,000 Btu/h

30,000 Btu/h

Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove

11

Image 11
Contents Ultimate U39 Regency Unit SpecificationsTable of Contents Copy of Safety Label for U39 Gas Stove Safety LabelInformation for Mobile InstallationSpecifications Save These InstructionsClearances to Combustibles General Safety InformationInstallation Checklist Locating Your Ultimate GAS Stove Louver InstallationInstallation Precautions Venting IntroductionExterior Vent Terminal 4DT-AJB Rigid Pipe Venting Components ListAlternate Horizontal Termination Caps Rigid Pipe Venting SystemsVent Restrictor Position Safety Precautions for the InstallerRigid Pipe Venting Arrangements Horizontal Terminations for All Venting SystemsVertical Venting with Two 2 90o Elbows Horizontal Venting with Two 2 90o ElbowsSions on pages 8 to DV Stove Horizontal Vent KITQty. Description OptionalBrick, concrete, or other types of sidings Dismantle all pipe sections including vent terminalDURA-VENT Venting Components Planning Your Dura-Vent InstallationMinimum components for a Dura-Vent Horizontal Installation DURA-VENT Termination KITSnorkel Terminations DURA-VENT Horizontal InstallationsBelow Grade Installation Cathedral Ceilings Offset ChartConverting a Factory Built Metal Chimney Support Extensions Round Rdse or Square SqseGeneral Converting a Masonry Chimney System Data GAS ConnectionHigh Elevation System Data U39 with 40,000 BTUConversion from Natural GAS to Propane Pilot assembly is now accessible for stepsValve Description GAS Pipe Pressure TestingConversion to Lower BTU Rating U39 with 30,000 Btu/h Aeration AdjustmentLOG SET Installation U39 with 38,000 Btu/hPackaged separately Front Door InstallationOptional Wall Thermostat WiringOptional Remote Control Operating Instructions Copy of the Lighting Plate instructions Adjusting Flame HeightNormal Operating Sounds GAS Appliances Automatic Convection FAN OperationGOLD-PLATED Doors MaintenanceMaintenance Instructions General Vent MaintenanceDoor Gasket LOG ReplacementLatch Adjustment Glass ReplacementReplacing U39 Fan FAN MaintenanceAlternate Fan Access To remove U39 fanRemoving Valve Description Parts ListU39 Main Assembly U39 Burner & LOG Assembly U39 Door Assemblies Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

U39-NG, U39-LP specifications

The Regency U39-LP and U39-NG are modern gas fireplaces designed to enhance the aesthetic appeal and functionality of any space while delivering exceptional performance. These units are part of Regency's commitment to innovation and sustainability, providing homeowners with an efficient heating solution that seamlessly integrates into various home styles.

One of the standout features of the U39 series is its versatility in fuel options. The U39-LP operates on liquid propane, while the U39-NG utilizes natural gas. This flexibility allows homeowners to choose the best option suited for their existing infrastructure and personal preferences. Both models are designed to deliver efficient heating with an impressive BTU output, ensuring that rooms stay warm and comfortable during colder months.

The U39 series is equipped with cutting-edge technologies, including a state-of-the-art control system that allows users to easily adjust the flame height and heat output. This feature not only enhances user convenience but also promotes energy efficiency by allowing adjustments based on real-time heating needs. The inclusion of an optional remote control further simplifies the operation, enabling users to manage their fireplace from anywhere in the room.

Another remarkable aspect of the Regency U39-LP and U39-NG is the clean, contemporary design. The linear shape and large viewing area provide an unobstructed view of the flames, adding a stunning focal point to any living space. The customizable options for finishes and surround materials mean that homeowners can tailor the fireplace to perfectly match their décor, whether it be modern, traditional, or somewhere in between.

Safety is a top priority for Regency, and the U39 series includes multiple safety features to ensure peace of mind. An integrated safety shut-off system is designed to automatically turn off the unit in case of emergencies, while tempered glass doors protect against accidental burns.

In summary, the Regency U39-LP and U39-NG gas fireplaces embody a blend of functionality, beauty, and safety. With their high thermal efficiency, user-friendly technologies, and elegant design, these fireplaces are an ideal choice for anyone looking to elevate their home heating experience while enjoying the charm of a glowing fire. Whether it's for a cozy gathering with family or a quiet evening alone, the U39 series stands out as a stylish solution with exceptional performance.