Regency U39-NG, U39-LP installation manual Front Door Installation, Packaged separately

Page 25
Diagram 1

INSTALLATION

7)Place the Left Top Log D)02-46 on the pin on Log B)02-56 and on top of the cutout on Log A)02-65.

A)02-65

D)02-46

-

C)02-44

PinCutout

8)Place Front Right Log E)02-45 on the two pins as shown.

E)02-45

11)Position notch in Front Right Log G)02-48 on Log F)02-47 and push the bottom right edge against the bracket on the burner tray.

-48

-65

-

Notch

G)02-48

45

FRONT DOOR

INSTALLATION

(packaged separately)

1)Open the two side panels.

2)Slide the door onto the two

hinge pins mak-

i n g

sure the

two

 

pieces

are

 

flush together.

 

See diagram 1.

 

3) Close the door.

The

latch plate must be centered around the alignment pin. See dia- gram 2. If the latch plate interferes with the cor- ner of the stove you may want to angle the

plate slightly so the door closes easier.

4)The latches should already be at the proper setting. If they are too hard or too easy to close, you may want to adjust them by loosening the latch catch. See diagram 3.

9)Place the lava rock in the area between the left and right logs, leaving a space in the middle for log (F) 02-47.

10)Place the notch in Center Log F)02-47 over Log E)02-45 and across the cutout on Log A)02-65.

-

A)02-65

Bracket

The bottom right edge of Log G)02-48 must sit snugly against the bracket

12)Test fire to ensure proper light off (make sure flame flows smoothly from one end of burner to the other. If there is any flame hesitation, check that area for any block- age of the burner port.

-

-46

 

-

 

 

B)02-56

F)02

-

E)02-45

 

C)02-44

Diagram 2

5)Remove the blue plastic protective coating from the glass.

6)Test the seal around the door by placing a piece of paper between the unit and the door, close the door and try to pull the paper out. If it slips out easily, then the door is not properly sealed. Tighten or loosen the latch. See diagram 3.

E)02-45

Notch Cutout

Diagram 3

Note: The door latch may require ad- justment as the door gasket mate- rial compresses after a few fires and after glass replacement. Turn the latch catch inward or outward to loosen or tighten.

Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove

25

Image 25
Contents Ultimate U39 Regency Unit SpecificationsTable of Contents Copy of Safety Label for U39 Gas Stove Safety LabelSpecifications InstallationSave These Instructions Information for MobileInstallation Checklist General Safety InformationClearances to Combustibles Installation Precautions Louver InstallationVenting Introduction Locating Your Ultimate GAS StoveExterior Vent Terminal 4DT-AJB Rigid Pipe Venting Components ListAlternate Horizontal Termination Caps Rigid Pipe Venting SystemsRigid Pipe Venting Arrangements Safety Precautions for the InstallerHorizontal Terminations for All Venting Systems Vent Restrictor PositionVertical Venting with Two 2 90o Elbows Horizontal Venting with Two 2 90o ElbowsQty. Description DV Stove Horizontal Vent KITOptional Sions on pages 8 toBrick, concrete, or other types of sidings Dismantle all pipe sections including vent terminalMinimum components for a Dura-Vent Horizontal Installation Planning Your Dura-Vent InstallationDURA-VENT Termination KIT DURA-VENT Venting ComponentsSnorkel Terminations DURA-VENT Horizontal InstallationsBelow Grade Installation Cathedral Ceilings Offset ChartGeneral Support Extensions Round Rdse or Square SqseConverting a Factory Built Metal Chimney Converting a Masonry Chimney High Elevation GAS ConnectionSystem Data U39 with 40,000 BTU System DataConversion from Natural GAS to Propane Pilot assembly is now accessible for stepsConversion to Lower BTU Rating GAS Pipe Pressure TestingValve Description LOG SET Installation Aeration AdjustmentU39 with 38,000 Btu/h U39 with 30,000 Btu/hPackaged separately Front Door InstallationOptional Remote Control WiringOptional Wall Thermostat Operating Instructions Normal Operating Sounds GAS Appliances Adjusting Flame HeightAutomatic Convection FAN Operation Copy of the Lighting Plate instructionsMaintenance Instructions MaintenanceGeneral Vent Maintenance GOLD-PLATED DoorsLatch Adjustment LOG ReplacementGlass Replacement Door GasketAlternate Fan Access FAN MaintenanceTo remove U39 fan Replacing U39 FanRemoving Valve U39 Main Assembly Parts ListDescription U39 Burner & LOG Assembly U39 Door Assemblies Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

U39-NG, U39-LP specifications

The Regency U39-LP and U39-NG are modern gas fireplaces designed to enhance the aesthetic appeal and functionality of any space while delivering exceptional performance. These units are part of Regency's commitment to innovation and sustainability, providing homeowners with an efficient heating solution that seamlessly integrates into various home styles.

One of the standout features of the U39 series is its versatility in fuel options. The U39-LP operates on liquid propane, while the U39-NG utilizes natural gas. This flexibility allows homeowners to choose the best option suited for their existing infrastructure and personal preferences. Both models are designed to deliver efficient heating with an impressive BTU output, ensuring that rooms stay warm and comfortable during colder months.

The U39 series is equipped with cutting-edge technologies, including a state-of-the-art control system that allows users to easily adjust the flame height and heat output. This feature not only enhances user convenience but also promotes energy efficiency by allowing adjustments based on real-time heating needs. The inclusion of an optional remote control further simplifies the operation, enabling users to manage their fireplace from anywhere in the room.

Another remarkable aspect of the Regency U39-LP and U39-NG is the clean, contemporary design. The linear shape and large viewing area provide an unobstructed view of the flames, adding a stunning focal point to any living space. The customizable options for finishes and surround materials mean that homeowners can tailor the fireplace to perfectly match their décor, whether it be modern, traditional, or somewhere in between.

Safety is a top priority for Regency, and the U39 series includes multiple safety features to ensure peace of mind. An integrated safety shut-off system is designed to automatically turn off the unit in case of emergencies, while tempered glass doors protect against accidental burns.

In summary, the Regency U39-LP and U39-NG gas fireplaces embody a blend of functionality, beauty, and safety. With their high thermal efficiency, user-friendly technologies, and elegant design, these fireplaces are an ideal choice for anyone looking to elevate their home heating experience while enjoying the charm of a glowing fire. Whether it's for a cozy gathering with family or a quiet evening alone, the U39 series stands out as a stylish solution with exceptional performance.