INSTALLATION

IMPORTANT:

SAVE THESE

INSTRUCTIONS

The ULTIMATE Direct Vent Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the in- structions in this manual first. Consult the building authority having jurisdiction to deter- mine the need for a permit prior to starting the installation.

Note: Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or prop- erty damage. Failure to follow these instructions may also void your fire insurance and/or war- ranty.

Note: These instructions take prece- dence over Simpson Dura-Vent instructions.

Installations,Sites,andCommunitiesANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.

This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.

This Regency Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit.

This Regency Mobile/Manufactured Home listed appliance comes equipped with a dedicated #8 ground lug to which an 18 gauge copper wire from the steel chassis ground must be attached.

AND CIRCULATING AIR PASSAGE- WAYS OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LO- CATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERA- TURES, ESPECIALLY THE FIRE- PLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS

SPECIFICATIONS

Fuels: U39-NG is approved for use with nat- ural gas.

U39-LP is approved for use with lique- fied petroleum gases (propane).

Electrical: 120V A.C. system.

Circulation Fan: Variable speed, 125/75.

Log Sets: Ceramic fibre, 7 per set.

Vent System:Coaxial (6-5/8" outer / 4" inner liner) rigid flue and termination cap.

INFORMATION FOR

MOBILE/

MANUFACTURED HOMES AFTER FIRST SALE

This Regency product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to thefollowing standards: CAN/CGA- 2.17-M91 and ANSI Z21.88b-2003/CSA 2.33b- 2003.

This Direct Vent System Appliance must be installed in accordance with the manufactur- er's installation instructions and the Manufac- tured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or thecurrentStandard of Fire Safety Criteria for Manufactured Home

This appliance may only be in- stalled in an aftermarket perma- nently located, manufactured (mo- bile) home, where not prohibited by local codes.

This appliance is only use with the type of gas indicated on the rating plate. This appliance is not con- vertible for use with other gases, unless a certified kit is used.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

INSTALLATION AND REPAIRS SHOULD BE DONE BY A QUALI- FIED SERVICE PERSON. THIS AP- PLIANCE SHOULD BE INSTALLED, REPAIRED, INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A QUALIFIED SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, ETC. IT IS IMPERATIVE THAT THE CON- TROL COMPARTMENT, BURNERS

OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLI- ANCE.

1)Provide adequate clearances for servic- ing, proper operation and around the air openings into the combustion chamber.

2)The appliance may be installed on a flat, solid, continuous surface (e.g. wood, met- al, concrete). This may be the floor, or it can be raised up on a platform to enhance its visual impact. The appliance may be in- stalled on carpeting, tile, wood flooring or other combustible material, because the appliance's metal pedestal base extends the full width and depth of the appliance. The ULTIMATE Direct Vent Freestanding Gas Stove can be installed in a wide variety of ways and will fit nearly any room layout. It may be installed in a recessed position, framed out into the room, or across a corner.

3)The ULTIMATE Direct Vent Freestanding Gas Stove is approved for alcove installa- tions, which meet the clearances listed on page 7. This unit is approved for manufac- tured home installations, see page 11 for the required vent arrangements. If installed

Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove

5

Image 5
Contents Ultimate U39 Regency Unit SpecificationsTable of Contents Copy of Safety Label for U39 Gas Stove Safety LabelSpecifications InstallationSave These Instructions Information for MobileClearances to Combustibles General Safety InformationInstallation Checklist Installation Precautions Louver InstallationVenting Introduction Locating Your Ultimate GAS StoveExterior Vent Terminal 4DT-AJB Rigid Pipe Venting Components ListAlternate Horizontal Termination Caps Rigid Pipe Venting SystemsRigid Pipe Venting Arrangements Safety Precautions for the InstallerHorizontal Terminations for All Venting Systems Vent Restrictor PositionVertical Venting with Two 2 90o Elbows Horizontal Venting with Two 2 90o ElbowsQty. Description DV Stove Horizontal Vent KITOptional Sions on pages 8 toBrick, concrete, or other types of sidings Dismantle all pipe sections including vent terminalMinimum components for a Dura-Vent Horizontal Installation Planning Your Dura-Vent InstallationDURA-VENT Termination KIT DURA-VENT Venting ComponentsSnorkel Terminations DURA-VENT Horizontal InstallationsBelow Grade Installation Cathedral Ceilings Offset ChartConverting a Factory Built Metal Chimney Support Extensions Round Rdse or Square SqseGeneral Converting a Masonry Chimney High Elevation GAS ConnectionSystem Data U39 with 40,000 BTU System DataConversion from Natural GAS to Propane Pilot assembly is now accessible for stepsValve Description GAS Pipe Pressure TestingConversion to Lower BTU Rating LOG SET Installation Aeration AdjustmentU39 with 38,000 Btu/h U39 with 30,000 Btu/hPackaged separately Front Door InstallationOptional Wall Thermostat WiringOptional Remote Control Operating Instructions Normal Operating Sounds GAS Appliances Adjusting Flame HeightAutomatic Convection FAN Operation Copy of the Lighting Plate instructionsMaintenance Instructions MaintenanceGeneral Vent Maintenance GOLD-PLATED DoorsLatch Adjustment LOG ReplacementGlass Replacement Door GasketAlternate Fan Access FAN MaintenanceTo remove U39 fan Replacing U39 FanRemoving Valve Description Parts ListU39 Main Assembly U39 Burner & LOG Assembly U39 Door Assemblies Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

U39-NG, U39-LP specifications

The Regency U39-LP and U39-NG are modern gas fireplaces designed to enhance the aesthetic appeal and functionality of any space while delivering exceptional performance. These units are part of Regency's commitment to innovation and sustainability, providing homeowners with an efficient heating solution that seamlessly integrates into various home styles.

One of the standout features of the U39 series is its versatility in fuel options. The U39-LP operates on liquid propane, while the U39-NG utilizes natural gas. This flexibility allows homeowners to choose the best option suited for their existing infrastructure and personal preferences. Both models are designed to deliver efficient heating with an impressive BTU output, ensuring that rooms stay warm and comfortable during colder months.

The U39 series is equipped with cutting-edge technologies, including a state-of-the-art control system that allows users to easily adjust the flame height and heat output. This feature not only enhances user convenience but also promotes energy efficiency by allowing adjustments based on real-time heating needs. The inclusion of an optional remote control further simplifies the operation, enabling users to manage their fireplace from anywhere in the room.

Another remarkable aspect of the Regency U39-LP and U39-NG is the clean, contemporary design. The linear shape and large viewing area provide an unobstructed view of the flames, adding a stunning focal point to any living space. The customizable options for finishes and surround materials mean that homeowners can tailor the fireplace to perfectly match their décor, whether it be modern, traditional, or somewhere in between.

Safety is a top priority for Regency, and the U39 series includes multiple safety features to ensure peace of mind. An integrated safety shut-off system is designed to automatically turn off the unit in case of emergencies, while tempered glass doors protect against accidental burns.

In summary, the Regency U39-LP and U39-NG gas fireplaces embody a blend of functionality, beauty, and safety. With their high thermal efficiency, user-friendly technologies, and elegant design, these fireplaces are an ideal choice for anyone looking to elevate their home heating experience while enjoying the charm of a glowing fire. Whether it's for a cozy gathering with family or a quiet evening alone, the U39 series stands out as a stylish solution with exceptional performance.