Regency U39-NG, U39-LP Maintenance Instructions, General Vent Maintenance, GOLD-PLATED Doors

Page 29

MAINTENANCE

MAINTENANCE

INSTRUCTIONS

1)Always turn off the valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged.

2)Clean glass (never when unit is hot), appli- ance, louvers, and door with a damp cloth. Never use an abrasive cleaner. The gold louvers (and optional gold door) may be scratched if abrasives are used to clean them.

The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint (not with wall paint). Regency uses StoveBright Paint - Metallic Black #6309.

3)Make a periodic check of burner for proper position and condition. Visually check the flame of the burner periodically, making sure the flames are steady; not lifting or floating. If there is a problem, call a qualified service person.

4)Caution: Label all wires prior to disconnec- tion when servicing controls. Wiring errors can cause improper and dangerous oper- ation.

5)The appliance and venting system must be inspected before use, and at least annually, by a qualified field service person, to en- sure that the flow of combustion and ven- tilation air is not obstructed.

During the annual service call, the burners should be removed from the burner tray and cleaned. Replace the embers but do not block the pilot.

6)Keep the area near the appliance clear and free from combustible materials, gasoline, and other flammable vapours and liquids.

WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFUL- LY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE AP- PLIANCE.

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WA- TER. IMMEDIATELY CALL A QUAL- IFIED SERVICE TECHNICIAN TO INSPECT THE APPLIANCE AND TO REPLACE ANY PART OF CON- TROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.

CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV- ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERAT- ING THE APPLIANCE.

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE AP- PLIANCE.

7)Each time the appliance is lit, it may cause condensation and fog the glass. This con- densation and fog is normal and will disap- pear in a few minutes as the glass heats up.

Never operate the appliance without the glass properly secured in place or with the door open.

8)Periodically check the pilot flames. Correct flame pattern has three strong blue flames: 1 flowing around the thermopile and 1 around the thermocouple, and 1 flowing across the rear of the burner (it does not have to be touching the burner).

Note: If you have an incorrect flame pat- tern, contact your Regency dealer for further instructions.

Top View of pilot flame

Incorrect flame pattern will have small, proba- bly yellow flames, not coming into proper con- tact with the rear of the burner or thermopile.

Top View of pilot flame

GENERAL VENT

MAINTENANCE

Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows:

1)Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These compo- nents should be replaced immediately.

2)Remove the Cap, and shine a flashlight down the Vent. Remove any bird nests, or other foreign material.

3)Check for evidences of excessive conden- sation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fittings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.

4)Inspect joints, to verify that no pipe sections or fittings have been disturbed, and conse- quently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.

GOLD-PLATED DOORS

The 24 carat gold plated finish on the door requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the finish and void the warranty.

Clean any fingerprints off before turning the unit on. If the door starts to discolour, check the gasket seal and replace if nec- essary.

Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove

29

Image 29
Contents Ultimate U39 Regency Unit SpecificationsTable of Contents Copy of Safety Label for U39 Gas Stove Safety LabelSpecifications InstallationSave These Instructions Information for MobileClearances to Combustibles General Safety InformationInstallation Checklist Installation Precautions Louver InstallationVenting Introduction Locating Your Ultimate GAS StoveExterior Vent Terminal 4DT-AJB Rigid Pipe Venting Components ListAlternate Horizontal Termination Caps Rigid Pipe Venting SystemsRigid Pipe Venting Arrangements Safety Precautions for the InstallerHorizontal Terminations for All Venting Systems Vent Restrictor PositionVertical Venting with Two 2 90o Elbows Horizontal Venting with Two 2 90o ElbowsQty. Description DV Stove Horizontal Vent KITOptional Sions on pages 8 toBrick, concrete, or other types of sidings Dismantle all pipe sections including vent terminalMinimum components for a Dura-Vent Horizontal Installation Planning Your Dura-Vent InstallationDURA-VENT Termination KIT DURA-VENT Venting ComponentsSnorkel Terminations DURA-VENT Horizontal InstallationsBelow Grade Installation Cathedral Ceilings Offset ChartConverting a Factory Built Metal Chimney Support Extensions Round Rdse or Square SqseGeneral Converting a Masonry Chimney High Elevation GAS ConnectionSystem Data U39 with 40,000 BTU System DataConversion from Natural GAS to Propane Pilot assembly is now accessible for stepsValve Description GAS Pipe Pressure TestingConversion to Lower BTU Rating LOG SET Installation Aeration AdjustmentU39 with 38,000 Btu/h U39 with 30,000 Btu/hPackaged separately Front Door InstallationOptional Wall Thermostat WiringOptional Remote Control Operating Instructions Normal Operating Sounds GAS Appliances Adjusting Flame HeightAutomatic Convection FAN Operation Copy of the Lighting Plate instructionsMaintenance Instructions MaintenanceGeneral Vent Maintenance GOLD-PLATED DoorsLatch Adjustment LOG ReplacementGlass Replacement Door GasketAlternate Fan Access FAN MaintenanceTo remove U39 fan Replacing U39 FanRemoving Valve Description Parts ListU39 Main Assembly U39 Burner & LOG Assembly U39 Door Assemblies Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

U39-NG, U39-LP specifications

The Regency U39-LP and U39-NG are modern gas fireplaces designed to enhance the aesthetic appeal and functionality of any space while delivering exceptional performance. These units are part of Regency's commitment to innovation and sustainability, providing homeowners with an efficient heating solution that seamlessly integrates into various home styles.

One of the standout features of the U39 series is its versatility in fuel options. The U39-LP operates on liquid propane, while the U39-NG utilizes natural gas. This flexibility allows homeowners to choose the best option suited for their existing infrastructure and personal preferences. Both models are designed to deliver efficient heating with an impressive BTU output, ensuring that rooms stay warm and comfortable during colder months.

The U39 series is equipped with cutting-edge technologies, including a state-of-the-art control system that allows users to easily adjust the flame height and heat output. This feature not only enhances user convenience but also promotes energy efficiency by allowing adjustments based on real-time heating needs. The inclusion of an optional remote control further simplifies the operation, enabling users to manage their fireplace from anywhere in the room.

Another remarkable aspect of the Regency U39-LP and U39-NG is the clean, contemporary design. The linear shape and large viewing area provide an unobstructed view of the flames, adding a stunning focal point to any living space. The customizable options for finishes and surround materials mean that homeowners can tailor the fireplace to perfectly match their décor, whether it be modern, traditional, or somewhere in between.

Safety is a top priority for Regency, and the U39 series includes multiple safety features to ensure peace of mind. An integrated safety shut-off system is designed to automatically turn off the unit in case of emergencies, while tempered glass doors protect against accidental burns.

In summary, the Regency U39-LP and U39-NG gas fireplaces embody a blend of functionality, beauty, and safety. With their high thermal efficiency, user-friendly technologies, and elegant design, these fireplaces are an ideal choice for anyone looking to elevate their home heating experience while enjoying the charm of a glowing fire. Whether it's for a cozy gathering with family or a quiet evening alone, the U39 series stands out as a stylish solution with exceptional performance.