Regency U39-NG Louver Installation, Venting Introduction, Locating Your Ultimate GAS Stove

Page 7

INSTALLATION

Minimum ceiling

height is 36"/914mm

from top of unit.

MANUFACTURED MOBILE HOME ADDITIONAL REQUIREMENTS

LOUVER

INSTALLATION

1)Attach the top & bottom louvers to the side stove panel using 2 screws per side.

VENTING

INTRODUCTION

The DV Stove Horizontal Vent Kit and the Simpson Dura-Vent Direct Vent System Model DV-GS venting systems, in combination with the ULTIMATE Direct Vent Freestanding Gas Stove, U39-NG, and U39-LP, have been tested and listed as direct vent heater systems by Warnock Hersey. If converting a Class-A Metal Chimney or Masonry Chimney to a Direct Vent system, see instructions on pages 19 to 21.

These units use the "balanced flue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.

Note: These flue pipes must not be con- nected to any other appliance.

1)Ensure that structural members are not cut or weakened during installation.

2)Ensure proper grounding using the #8 ground lug provided.

3)Appliance must be anchored to the floor with the supplied anchoring methods.

LOCATING YOUR

ULTIMATE GAS STOVE

When selecting a location for your stove, ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper opera- tion.

A)Cross Corner

B)Room Divider

C)Island

D)Flat on Wall

E)Flat on Wall Corner

F)Flush with Wall/ Alcove

For Vent Termination require- ments, see page 8.

COMBUSTION AND VENTILATION AIR

The combustion air from this appliance is drawn from outside the building through the outer flue.

Extra provision for combustion air inside the room is not required.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent sys- tems are prohibited.

IMPORTANT

Read all instructions carefully before starting the installation. Failure to follow these instruc- tions may create a fire or other safety hazard, and will void the warranty. Be sure to check the venting and clearance to combustible require- ments. Consult your local building codes before beginning installation.

The location of the termination cap must con- form to the requirements in the Exterior Vent Terminal Locations diagram on page 8.

INSTALLATION

PRECAUTIONS

These venting systems are engineered prod- ucts that have been designed and tested for use with the U39-NG, and U39-LP. The warran- ty will be voided and serious fire, health or other safety hazards may result from any of the following actions:

1)Installation of any damaged Direct Vent component

2)UnauthorizedmodificationoftheDirectVent System

3)Installation of any component part not man- ufactured or approved by Simpson Dura-

Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove

7

Image 7
Contents Ultimate U39 Regency Unit SpecificationsTable of Contents Copy of Safety Label for U39 Gas Stove Safety LabelInformation for Mobile InstallationSpecifications Save These InstructionsInstallation Checklist General Safety InformationClearances to Combustibles Locating Your Ultimate GAS Stove Louver InstallationInstallation Precautions Venting IntroductionExterior Vent Terminal 4DT-AJB Rigid Pipe Venting Components ListAlternate Horizontal Termination Caps Rigid Pipe Venting SystemsVent Restrictor Position Safety Precautions for the InstallerRigid Pipe Venting Arrangements Horizontal Terminations for All Venting SystemsVertical Venting with Two 2 90o Elbows Horizontal Venting with Two 2 90o ElbowsSions on pages 8 to DV Stove Horizontal Vent KITQty. Description OptionalBrick, concrete, or other types of sidings Dismantle all pipe sections including vent terminalDURA-VENT Venting Components Planning Your Dura-Vent InstallationMinimum components for a Dura-Vent Horizontal Installation DURA-VENT Termination KITSnorkel Terminations DURA-VENT Horizontal InstallationsBelow Grade Installation Cathedral Ceilings Offset ChartGeneral Support Extensions Round Rdse or Square SqseConverting a Factory Built Metal Chimney Converting a Masonry Chimney System Data GAS ConnectionHigh Elevation System Data U39 with 40,000 BTUConversion from Natural GAS to Propane Pilot assembly is now accessible for stepsConversion to Lower BTU Rating GAS Pipe Pressure TestingValve Description U39 with 30,000 Btu/h Aeration AdjustmentLOG SET Installation U39 with 38,000 Btu/hPackaged separately Front Door InstallationOptional Remote Control WiringOptional Wall Thermostat Operating Instructions Copy of the Lighting Plate instructions Adjusting Flame HeightNormal Operating Sounds GAS Appliances Automatic Convection FAN OperationGOLD-PLATED Doors MaintenanceMaintenance Instructions General Vent MaintenanceDoor Gasket LOG ReplacementLatch Adjustment Glass ReplacementReplacing U39 Fan FAN MaintenanceAlternate Fan Access To remove U39 fanRemoving Valve U39 Main Assembly Parts ListDescription U39 Burner & LOG Assembly U39 Door Assemblies Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

U39-NG, U39-LP specifications

The Regency U39-LP and U39-NG are modern gas fireplaces designed to enhance the aesthetic appeal and functionality of any space while delivering exceptional performance. These units are part of Regency's commitment to innovation and sustainability, providing homeowners with an efficient heating solution that seamlessly integrates into various home styles.

One of the standout features of the U39 series is its versatility in fuel options. The U39-LP operates on liquid propane, while the U39-NG utilizes natural gas. This flexibility allows homeowners to choose the best option suited for their existing infrastructure and personal preferences. Both models are designed to deliver efficient heating with an impressive BTU output, ensuring that rooms stay warm and comfortable during colder months.

The U39 series is equipped with cutting-edge technologies, including a state-of-the-art control system that allows users to easily adjust the flame height and heat output. This feature not only enhances user convenience but also promotes energy efficiency by allowing adjustments based on real-time heating needs. The inclusion of an optional remote control further simplifies the operation, enabling users to manage their fireplace from anywhere in the room.

Another remarkable aspect of the Regency U39-LP and U39-NG is the clean, contemporary design. The linear shape and large viewing area provide an unobstructed view of the flames, adding a stunning focal point to any living space. The customizable options for finishes and surround materials mean that homeowners can tailor the fireplace to perfectly match their décor, whether it be modern, traditional, or somewhere in between.

Safety is a top priority for Regency, and the U39 series includes multiple safety features to ensure peace of mind. An integrated safety shut-off system is designed to automatically turn off the unit in case of emergencies, while tempered glass doors protect against accidental burns.

In summary, the Regency U39-LP and U39-NG gas fireplaces embody a blend of functionality, beauty, and safety. With their high thermal efficiency, user-friendly technologies, and elegant design, these fireplaces are an ideal choice for anyone looking to elevate their home heating experience while enjoying the charm of a glowing fire. Whether it's for a cozy gathering with family or a quiet evening alone, the U39 series stands out as a stylish solution with exceptional performance.