Regency U39-NG DV Stove Horizontal Vent KIT, Qty. Description, Optional, Sions on pages 8 to

Page 13

INSTALLATION

DV STOVE HORIZONTAL VENT KIT

DV Stove Horizontal Vent Kit (2 ft. Part # 946-116 or 4 ft. Part # 946-216) includes all the parts needed to install the U39 with minimum horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents use the Dura-Vent system as shown on page 15.

Qty. Description

1)1 Rigid Pipe Section (Kit # 946-116: 2 ft. (1.2m) length,

Kit # 946-216: 4 ft. (1.2m) length), 6-1/2" (165mm) inside diameter

2)1 Flex Liner, compressed aluminium 2 ply liner, 4" (102mm) inside diameter

3)4 spring spacers

4)1 90 deg. Elbow

5)1 Adjustable pipe section 13-1/2" to 24" (343mm x 610mm), 2 pieces

6)1 Thimble Cover

7)1 Wall Thimble (2 pcs.)

8)1 Adapter

9)1 AstroCap Termination Cap

10)2 Trim Collar

11)1 tube of Mill-Pac, high temperature sealant

12)12 Screws, #8 x 1/2" Self tapping, Stainless Steel

13)13 Screws, #8 x 1/2" Self tapping, Black

14)4 Screws #8 x 1-1/2" Drill Point, Black

15)4 Screws #8 x 1-1/2" Drill Point, Stainless Steel

16)8 Wood screws #8 x 1"

Optional:

946-206 Vinyl Siding Standoff

for AstroCap

Note:

a)Liner sections should be continuous without any joints or seams.

b)This is an approved system, therefore components in this system must not be substituted for any other manufac- turer's products.

DV STOVE HORIZONTAL VENT KIT (# 946-116 & #946-216) INSTALLATION

Review the following sequence of in- structions which are typical of most in- stallations. The sequence may vary de- pending on wall thickness. Refer to vent location and clearance dimen-

sions on pages 8 to 13.

1)Set the unit in its desired location. Check to determine if wall studs will be in the way of the venting system, adjust location until all clearances are met and there are no obstructions.

Note: A 1-1/2"(38mm) clearance around the outer pipe must be maintained except that only a 1" (25mm) clearance is needed at the termination end.

IMPORTANT:

Do not locate termination hood where excessive snow or ice build- up may occur. Be sure to check vent termination area after snow falls, and clear to prevent accidental

Minimum Installation Height: U39: 59-3/4" ( 1518mm)

blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

2)Assemble a trialfit to determine the vertical center-line for the vent termination.

a)Cut a 9-1/2" x 9-1/2" (241mm x 241 mm) square hole on both the interior and exterior wall.

b)Install wall thimbles on both interior and exterior wall with 4 wood screws (#8 x 1") per thimble.

c)Attach the 2 piece adjustable pipe section to the vent terminal and slide into position from the exterior. The larger diameter end of the ad- justable pipe goes to the vent terminal.

d)Install the 90o elbow onto the adjust- able pipe to determine the vertical centerline of the starter collar on the unit.

Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove

13

Image 13
Contents Ultimate U39 Regency Unit SpecificationsTable of Contents Copy of Safety Label for U39 Gas Stove Safety LabelSpecifications InstallationSave These Instructions Information for MobileInstallation Checklist General Safety InformationClearances to Combustibles Installation Precautions Louver InstallationVenting Introduction Locating Your Ultimate GAS StoveExterior Vent Terminal 4DT-AJB Rigid Pipe Venting Components ListAlternate Horizontal Termination Caps Rigid Pipe Venting SystemsRigid Pipe Venting Arrangements Safety Precautions for the InstallerHorizontal Terminations for All Venting Systems Vent Restrictor PositionVertical Venting with Two 2 90o Elbows Horizontal Venting with Two 2 90o ElbowsQty. Description DV Stove Horizontal Vent KITOptional Sions on pages 8 toBrick, concrete, or other types of sidings Dismantle all pipe sections including vent terminalMinimum components for a Dura-Vent Horizontal Installation Planning Your Dura-Vent InstallationDURA-VENT Termination KIT DURA-VENT Venting ComponentsSnorkel Terminations DURA-VENT Horizontal InstallationsBelow Grade Installation Cathedral Ceilings Offset ChartGeneral Support Extensions Round Rdse or Square SqseConverting a Factory Built Metal Chimney Converting a Masonry Chimney High Elevation GAS ConnectionSystem Data U39 with 40,000 BTU System DataConversion from Natural GAS to Propane Pilot assembly is now accessible for stepsConversion to Lower BTU Rating GAS Pipe Pressure TestingValve Description LOG SET Installation Aeration AdjustmentU39 with 38,000 Btu/h U39 with 30,000 Btu/hPackaged separately Front Door InstallationOptional Remote Control WiringOptional Wall Thermostat Operating Instructions Normal Operating Sounds GAS Appliances Adjusting Flame HeightAutomatic Convection FAN Operation Copy of the Lighting Plate instructionsMaintenance Instructions MaintenanceGeneral Vent Maintenance GOLD-PLATED DoorsLatch Adjustment LOG ReplacementGlass Replacement Door GasketAlternate Fan Access FAN MaintenanceTo remove U39 fan Replacing U39 FanRemoving Valve U39 Main Assembly Parts ListDescription U39 Burner & LOG Assembly U39 Door Assemblies Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

U39-NG, U39-LP specifications

The Regency U39-LP and U39-NG are modern gas fireplaces designed to enhance the aesthetic appeal and functionality of any space while delivering exceptional performance. These units are part of Regency's commitment to innovation and sustainability, providing homeowners with an efficient heating solution that seamlessly integrates into various home styles.

One of the standout features of the U39 series is its versatility in fuel options. The U39-LP operates on liquid propane, while the U39-NG utilizes natural gas. This flexibility allows homeowners to choose the best option suited for their existing infrastructure and personal preferences. Both models are designed to deliver efficient heating with an impressive BTU output, ensuring that rooms stay warm and comfortable during colder months.

The U39 series is equipped with cutting-edge technologies, including a state-of-the-art control system that allows users to easily adjust the flame height and heat output. This feature not only enhances user convenience but also promotes energy efficiency by allowing adjustments based on real-time heating needs. The inclusion of an optional remote control further simplifies the operation, enabling users to manage their fireplace from anywhere in the room.

Another remarkable aspect of the Regency U39-LP and U39-NG is the clean, contemporary design. The linear shape and large viewing area provide an unobstructed view of the flames, adding a stunning focal point to any living space. The customizable options for finishes and surround materials mean that homeowners can tailor the fireplace to perfectly match their décor, whether it be modern, traditional, or somewhere in between.

Safety is a top priority for Regency, and the U39 series includes multiple safety features to ensure peace of mind. An integrated safety shut-off system is designed to automatically turn off the unit in case of emergencies, while tempered glass doors protect against accidental burns.

In summary, the Regency U39-LP and U39-NG gas fireplaces embody a blend of functionality, beauty, and safety. With their high thermal efficiency, user-friendly technologies, and elegant design, these fireplaces are an ideal choice for anyone looking to elevate their home heating experience while enjoying the charm of a glowing fire. Whether it's for a cozy gathering with family or a quiet evening alone, the U39 series stands out as a stylish solution with exceptional performance.