Regency Comprehensive Maintenance Guide for Fireplace Blower and U39 Stove

Page 31

MAINTENANCE

7)Tighten side panels nuts using the following procedure:

a.tighten top & bottom outside corner nuts

(2)

b.tighten inside nuts (3)

c.tighten top & bottom inside corners (2)

8)Tighten the 10 nuts on center glass retainer.

9)Repeat step 7 for other side panel.

10)Replace new gasket by gluing it in place.

11)Install door onto stove and check the seal.

FAN MAINTENANCE

If your fan requires maintenance or replace- ment, access to the fan is through the plate on the rear wall of the firebox. NOTE: the unit

MUST NOT be operated without the fan access panel securely in place and cor- rectly sealed.

IMPORTANT: These fans collect a lot of dust from within your home. En- sure you maintain these fan mo- tors on a regular basis by vacuum- ing out the fan squirrel cages, around the motor, and around the grills on the back of the stove.

IMPORTANT

Disconnect power supply

before servicing

WARNING:

Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

To remove U39 fan:

1)Unplug or disconnect power source to stove.

2)Remove all logs and the rear log support, then remove the 10 screws holding the access panel in place.

3)Unclip the black and white wires from the fan motor.

4)Open both side doors and gently pull the flex pipe away from the center, otherwise the fan can catch on the flex pipe during installation and tear the pipe. Do not tear or damage the flex pipe.

Alternate Fan Access:

If the rear access cover is accessible, it can be removed to provide access to the fan.

5)Lift fan off of the 2 pins, tip back and pull through firebox opening. Disconnect the green ground wire from the right side of the fan as soon as you can reach it.

Replacing U39 Fan:

Reverse the above steps (1 - 5). If necessary install a new gasket before replacing the fan access panel. Make sure the fan wires and the ground wire are reattached.

Hint for pushing fan down onto pins - rub a bit of dish soap on the grommet so it will slide more easily onto the pin. Check to make sure the fan is seated properly on the pins - try to move the fan back and forth, there should be no noise, if there is check that the grommets haven't come loose.

Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove

31

Image 31
Contents Ultimate U39 Regency Unit SpecificationsTable of Contents Copy of Safety Label for U39 Gas Stove Safety LabelInformation for Mobile InstallationSpecifications Save These InstructionsInstallation Checklist General Safety InformationClearances to Combustibles Locating Your Ultimate GAS Stove Louver InstallationInstallation Precautions Venting IntroductionExterior Vent Terminal 4DT-AJB Rigid Pipe Venting Components ListAlternate Horizontal Termination Caps Rigid Pipe Venting SystemsVent Restrictor Position Safety Precautions for the InstallerRigid Pipe Venting Arrangements Horizontal Terminations for All Venting SystemsVertical Venting with Two 2 90o Elbows Horizontal Venting with Two 2 90o ElbowsSions on pages 8 to DV Stove Horizontal Vent KITQty. Description OptionalBrick, concrete, or other types of sidings Dismantle all pipe sections including vent terminalDURA-VENT Venting Components Planning Your Dura-Vent InstallationMinimum components for a Dura-Vent Horizontal Installation DURA-VENT Termination KITSnorkel Terminations DURA-VENT Horizontal InstallationsBelow Grade Installation Cathedral Ceilings Offset ChartGeneral Support Extensions Round Rdse or Square SqseConverting a Factory Built Metal Chimney Converting a Masonry Chimney System Data GAS ConnectionHigh Elevation System Data U39 with 40,000 BTUConversion from Natural GAS to Propane Pilot assembly is now accessible for stepsConversion to Lower BTU Rating GAS Pipe Pressure TestingValve Description U39 with 30,000 Btu/h Aeration AdjustmentLOG SET Installation U39 with 38,000 Btu/hPackaged separately Front Door InstallationOptional Remote Control WiringOptional Wall Thermostat Operating Instructions Copy of the Lighting Plate instructions Adjusting Flame HeightNormal Operating Sounds GAS Appliances Automatic Convection FAN OperationGOLD-PLATED Doors MaintenanceMaintenance Instructions General Vent MaintenanceDoor Gasket LOG ReplacementLatch Adjustment Glass ReplacementReplacing U39 Fan FAN MaintenanceAlternate Fan Access To remove U39 fanRemoving Valve U39 Main Assembly Parts ListDescription U39 Burner & LOG Assembly U39 Door Assemblies Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

U39-NG, U39-LP specifications

The Regency U39-LP and U39-NG are modern gas fireplaces designed to enhance the aesthetic appeal and functionality of any space while delivering exceptional performance. These units are part of Regency's commitment to innovation and sustainability, providing homeowners with an efficient heating solution that seamlessly integrates into various home styles.

One of the standout features of the U39 series is its versatility in fuel options. The U39-LP operates on liquid propane, while the U39-NG utilizes natural gas. This flexibility allows homeowners to choose the best option suited for their existing infrastructure and personal preferences. Both models are designed to deliver efficient heating with an impressive BTU output, ensuring that rooms stay warm and comfortable during colder months.

The U39 series is equipped with cutting-edge technologies, including a state-of-the-art control system that allows users to easily adjust the flame height and heat output. This feature not only enhances user convenience but also promotes energy efficiency by allowing adjustments based on real-time heating needs. The inclusion of an optional remote control further simplifies the operation, enabling users to manage their fireplace from anywhere in the room.

Another remarkable aspect of the Regency U39-LP and U39-NG is the clean, contemporary design. The linear shape and large viewing area provide an unobstructed view of the flames, adding a stunning focal point to any living space. The customizable options for finishes and surround materials mean that homeowners can tailor the fireplace to perfectly match their décor, whether it be modern, traditional, or somewhere in between.

Safety is a top priority for Regency, and the U39 series includes multiple safety features to ensure peace of mind. An integrated safety shut-off system is designed to automatically turn off the unit in case of emergencies, while tempered glass doors protect against accidental burns.

In summary, the Regency U39-LP and U39-NG gas fireplaces embody a blend of functionality, beauty, and safety. With their high thermal efficiency, user-friendly technologies, and elegant design, these fireplaces are an ideal choice for anyone looking to elevate their home heating experience while enjoying the charm of a glowing fire. Whether it's for a cozy gathering with family or a quiet evening alone, the U39 series stands out as a stylish solution with exceptional performance.