Regency U39-LP, U39-NG installation manual Converting a Masonry Chimney

Page 20

INSTALLATION

4)Pass the flex pipe down through the center of the chimney system, and center the adaptor on the top of the chimney pipe. Drill four 1/8" diameter holes through the adap- tor and into the chimney top. Insure that you are in fact, drilling into the metal on the chimney. Twist-lock the Termination Cap (Part# 980 or 991) onto the Adaptor. (Dia- gram 3 and 4).

Converting a Masonry Chimney

Important: The existing masonry flue opening needs to have an area of at least a 36 sq. in. to insure proper intake/ex- haust flow.

1)Before cutting any holes, assemble the desired sections of black direct vent pipe to determine the center of the masonry pen- etration.

Diagram 3

Diagram 4

5)Pull the flex pipe down through the ceiling support box, until it protrudes approximate- ly 3" (76mm). Connect the flex pipe to the Retro Connector by slipping it into the

4-3/4" diameter sleeve on the top side of the Connector. Use 3 sheet metal screws to assemble these two parts.

6)Push the flex pipe back up into the ceiling support box, center the Retro Connector, and attach it to the support box, or decora- tive sleeve for double wall solid packed pipe, with the sheet metal screws (sup- plied). The holes in the Retro Connector are pre-punched. Diagram 5.

Diagram 5

7)The connection between the appliance and the Retro Connector may be completed with sections of black direct vent pipe, together with an adjustable length.

Diagram 6

2)Once the center point of the penetration has been determined, cut a 6" (152mm) dia. hole in the masonry. Be careful, if the hole is too large, the Retro Connector might not mount properly, and if the hole is too small, then the appliance might starve for intake air. If there is a frame wall in front of the masonry wall, cut and frame a 10" (254mm) clear square opening in the wall (centered around the 6" (152mm) masonry opening). IF there is sheet rock only (no studs) in front of the masonry, the 10" (254mm) clear opening is still needed, but does not need to be framed. This allows the Retro Connector to mount directly on the masonry and provide clear- ance to the combustibles. Diagram 11.

3)Secure the Flashing (Part # 705C) to the top of the masonry chimney using a bead of non-hardening sealant-adhesive. If the Flashing is larger than the top of the chim- ney, then cut and fold flashing as needed to fit chimney. Diagram 7.

Diagram 7

4)To determine the length of flex required, measure from 3" (76mm) above the top of the Flashing down to the level of the open- ing. Add to this measurement the distance from the center of the chimney to out through the wall. Cut a piece of 4" flex to this length (the flex should already be extended to its nominal length).

5)Connect the 4" flex liner to the Top Adaptor (Part # 985K) using 3 sheet metal screws. Diagram 2.

6)Feed the 4" flex liner through the Flashing into the chimney. Continue to feed the liner out through the opening in the masonry wall.

7)Secure the Top Adaptor to the Flashing. Use 3 sheet metal screws through the side of the adaptor into the flange on the Flashing (diagram 8). Twist lock the Termination Cap (Part # 980 or 991) on to the Top Adaptor.

Diagram 8

8)Attach the flex to the Retro Connector. Use 3 sheet metal screws to attach the flex liner to the Connector. Diagram 9. Mount the Retro Connector to the masonry wall using masonry bolts. Re-drill larger holes on con- nector as needed. Be careful to insure that the connector is centered in the opening and the mounting holes line up with the masonry wall.

20

Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove

Image 20
Contents Ultimate U39 Unit Specifications RegencyTable of Contents Safety Label Copy of Safety Label for U39 Gas StoveInstallation SpecificationsSave These Instructions Information for MobileClearances to Combustibles General Safety InformationInstallation Checklist Louver Installation Installation PrecautionsVenting Introduction Locating Your Ultimate GAS StoveExterior Vent Terminal Rigid Pipe Venting Components List 4DT-AJBRigid Pipe Venting Systems Alternate Horizontal Termination CapsSafety Precautions for the Installer Rigid Pipe Venting ArrangementsHorizontal Terminations for All Venting Systems Vent Restrictor PositionHorizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o ElbowsDV Stove Horizontal Vent KIT Qty. DescriptionOptional Sions on pages 8 toDismantle all pipe sections including vent terminal Brick, concrete, or other types of sidingsPlanning Your Dura-Vent Installation Minimum components for a Dura-Vent Horizontal InstallationDURA-VENT Termination KIT DURA-VENT Venting ComponentsDURA-VENT Horizontal Installations Snorkel TerminationsBelow Grade Installation Offset Chart Cathedral CeilingsConverting a Factory Built Metal Chimney Support Extensions Round Rdse or Square SqseGeneral Converting a Masonry Chimney GAS Connection High ElevationSystem Data U39 with 40,000 BTU System DataPilot assembly is now accessible for steps Conversion from Natural GAS to PropaneValve Description GAS Pipe Pressure TestingConversion to Lower BTU Rating Aeration Adjustment LOG SET InstallationU39 with 38,000 Btu/h U39 with 30,000 Btu/hFront Door Installation Packaged separatelyOptional Wall Thermostat WiringOptional Remote Control Operating Instructions Adjusting Flame Height Normal Operating Sounds GAS AppliancesAutomatic Convection FAN Operation Copy of the Lighting Plate instructionsMaintenance Maintenance InstructionsGeneral Vent Maintenance GOLD-PLATED DoorsLOG Replacement Latch AdjustmentGlass Replacement Door GasketFAN Maintenance Alternate Fan AccessTo remove U39 fan Replacing U39 FanRemoving Valve Description Parts ListU39 Main Assembly U39 Burner & LOG Assembly U39 Door Assemblies Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Regency U39 Ultimate Direct Vent Freestanding Gas Stove Warranty ConditionsInstaller Please complete the following information

U39-NG, U39-LP specifications

The Regency U39-LP and U39-NG are modern gas fireplaces designed to enhance the aesthetic appeal and functionality of any space while delivering exceptional performance. These units are part of Regency's commitment to innovation and sustainability, providing homeowners with an efficient heating solution that seamlessly integrates into various home styles.

One of the standout features of the U39 series is its versatility in fuel options. The U39-LP operates on liquid propane, while the U39-NG utilizes natural gas. This flexibility allows homeowners to choose the best option suited for their existing infrastructure and personal preferences. Both models are designed to deliver efficient heating with an impressive BTU output, ensuring that rooms stay warm and comfortable during colder months.

The U39 series is equipped with cutting-edge technologies, including a state-of-the-art control system that allows users to easily adjust the flame height and heat output. This feature not only enhances user convenience but also promotes energy efficiency by allowing adjustments based on real-time heating needs. The inclusion of an optional remote control further simplifies the operation, enabling users to manage their fireplace from anywhere in the room.

Another remarkable aspect of the Regency U39-LP and U39-NG is the clean, contemporary design. The linear shape and large viewing area provide an unobstructed view of the flames, adding a stunning focal point to any living space. The customizable options for finishes and surround materials mean that homeowners can tailor the fireplace to perfectly match their décor, whether it be modern, traditional, or somewhere in between.

Safety is a top priority for Regency, and the U39 series includes multiple safety features to ensure peace of mind. An integrated safety shut-off system is designed to automatically turn off the unit in case of emergencies, while tempered glass doors protect against accidental burns.

In summary, the Regency U39-LP and U39-NG gas fireplaces embody a blend of functionality, beauty, and safety. With their high thermal efficiency, user-friendly technologies, and elegant design, these fireplaces are an ideal choice for anyone looking to elevate their home heating experience while enjoying the charm of a glowing fire. Whether it's for a cozy gathering with family or a quiet evening alone, the U39 series stands out as a stylish solution with exceptional performance.