Regency L900-LP Unit Installation With Vertical Termination, This allows for small adjustments

Page 24

INSTALLATION

INSTALLATION

UNIT INSTALLATION

WITH VERTICAL

TERMINATION

(Rigid Vent Systems)

Note: A clearance of 2"(51mm) must be maintained; except when passing through a wall, ceiling, or at the termination where the use of a firestop or wall thimble reduces the required clearance to 1-1/2" (38mm). We recommend framing a 11"(279mm) x 11"(279mm) (inside dimensions) hole to give structural rigidity for mounting the termination.

1)Maintain the 2" (51mm)

clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafter, or other nearby combustible surfaces. Do not pack air spaces with insulation. Check "Venting Arrangemnt - Vertical Termination" s e c t i o n f o r t h e maximum vertical rise of the venting system and the maximum horizontal offset limitations.

Diagram 1

2)Setthegasappliance initsdesiredlocation. Drop a plumb bob

downfromtheceiling

 

to the position of the

 

appliance fl ue exit,

 

andmarkthelocation

 

where the vent will

 

penetrate the ceiling.

 

Drill a small hole at

 

his point. Next, drop

 

a plumb bob from

 

the roof to the hole

 

previously drilled in

 

the ceiling, and mark

 

the spot where the

Diagram 2

vent will penetrate the roof. Determine if ceiling joists, roof rafters or other framing will obstruct the venting system. You may wish to relocate the appliance or to offset, as shown in Diagram 2 to avoid cutting load bearing members.

3)AFirestop spacer must be installed in the fl oor or ceiling of every level.

Diagram 3

4)Assemble the desired lengths of pipe and elbows. Ensure that all pipes and elbow connections are in the fully twist-locked position and sealed.

Note:

For best results and optimum performance with each approved venting system, it is highly recommended to apply “Mill-Pac” sealant(supplied)toeveryinnerpipeconnec- tion. Failure to do so may result in drafting or performance issues not covered under warranty. Silicone (red RTV) is optional.

5)Cut a hole in the roof centered on the small drilled hole placed in the roof in Step 2. The hole should be of suffi cient size to meet the minimum requirements for clearance to combustiblesof1-1/2"(38mm).Sliptheflashing under the shingles (shingles should overlap half the flashing) as per Diagram 4.

Diagram 4: The upper half of the fl ashing is installed under the roofi ng material and not nailed down until the chimney is installed.

This allows for small adjustments.

6)Continue to assemble pipe lengths.

Note: If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (0.9 meter), to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose

(Diagram 2).

Galvanizedpipeisdesirableabovetheroofline duetoitshighercorrosionresistance.Continue to add pipe sections through the flashing until the height of the vent cap meets the minimum height requirements specified in Diagram 5 or local codes. Note that for steep roof pitches, the vertical height must be increased.

Diagram 5

 

Minimum Vent

Roof Pitch

 

Height

 

Feet

 

Meters

fl at to 7/12

2

 

0.61

over 7/12 to 8/12

2

 

0.61

over 8/12 to 9/12

2

 

0.61

over 9/12 to 10/12

2.5

 

0.76

over 10/12 to 11/12

3.25

 

0.99

over 11/12 to 12/12

4

 

1.22

over 12/12 to 14/12

5

 

1.52

over 14/12 to 16/12

6

 

1.83

over 16/12 to 18/12

7

 

2.13

over 18/12 to 20/12

7.5

 

2.29

A poor draft, or down drafting can result from highwindconditionsnearbigtreesoradjoining roof lines, in these cases, increasing the vent height may solve the problem.

7)Ensure vent is vertical and secure the base of the fl ashing to the roof with roofi ng rails, slide storm collar over the pipe section and seal with a mastic.

8)Install the vertical termination cap by twist- locking it.

Note: Any closets or storage spaces, which the vent passes through must be enclosed.

Offset Chart

24

Regency® L900 Direct Vent Gas Fireplace

Image 24
Contents Libertytm L900 Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Copy of Safety DecalListed Vented GAS Fireplace Heater Certified for / Certifiée pour Canada and U.S.ARequirements MA Code CO DetectorUnit Dimensions Installation General Safety InformationInstallation Checklist Important Message Save These InstructionsHeat Release KIT Hearth RequirementsManufactured Mobile Home Additional Requirements Locating Your GAS FireplaceClearances Mantel Clearances Mantel LEG ClearancesDiagram Framing & FinishingMaterial Unit Assembly Prior to InstallationVenting Introduction Vent Restrictor PositionLatch Location Vent Restrictor PlateExterior Vent Termination Requirements = Clearance to permanently closed window *min /30cmVenting Arrangements Horizontal Termination FlexFPI Kit # Length Contains Rigid Pipe Venting Systems Basic Horizontal & Vertical Terminations8 Rigid Pipe Cross Reference Chart 58DVA-16ABL676 & L900 Direct Vent Fireplace Vent Restrictor Setting Allowable Horizontal TerminationsHorizontal Venting with Two 2 90o Elbows Vertical Venting with Three 3 90o Elbows Allowable Vertical Terminations Unit Installation with Horizontal Termination Unit Installation With Vertical Termination This allows for small adjustmentsDiagram Minimum VentUnit Installation Astrocap XLGAS Line L900-NG System DataL900-LP System Data SIT 825 Valve DescriptionBACK-UP Battery Installation Hinge Door Heat Shield Power ModulePower Module Heat Shield Latch LocationConversion KIT #546-969 from NG to LP LP Conversion Kit Contains Qty DescriptionUsing a flat head screw driver Pilot Shield HeatClip Heat Shield J9 Jumper Location Unplug the power source Hinge DoorHeat Shield Bracket Heat ShieldModulating Coil Wires Bottom Brick PanelValve Tray Valve Tray Slightly RemovedPilot Shield ClipCable Tie J9 JumperBrick Panel Installation Handle with care. do not Force Into PositionF t Side Brick Panel Back Brick Panel Top Brick PanelOuterbox of Firebox Right Side Brick PanelLOG SET Installation 03-4203-42 03-41 03-43 Burner Tube03-44 03-45 03-41 03-43Aeration Adjustment Wiring DiagramLighting Procedure Operating InstructionsMatching Remote Handset & Control BOX ID Code Operating InstructionsShutdown Procedure Operation During Power OutageNormal Operating Sounds GAS Appliances STOP! Read the safety information above on this label Copy of Lighting Plate InstructionsMaintenance BACK-UP Battery Replacement Heat ShieldBracket Hinge Heat Door Power Module Replacement Bracket Heat ShieldControl Module Replacement Bracket Hinge HeatControl Module DC Sparker Replacement Battery CoverHeat Shield Replace the DC sparker Valve Tray Replacement Unplug the power sourceWires Bottom Brick PanelModulating Coil Valve Tray Slightly Removed Valve TrayParts List Main AssemblyDescription Parts List Burner & LOG Assembly Regency L900 Direct Vent Gas Fireplace Regency L900 Direct Vent Gas Fireplace Regency L900 Direct Vent Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information

L900-LP, L900-NG specifications

The Regency L900-NG and L900-LP are remarkable gas fireplaces that epitomize both elegance and efficiency, bringing a blend of modern technology and traditional aesthetics to any living space. Designed for versatility, these units are suitable for homes with natural gas (NG) or propane (LP) gas lines, thus catering to a wide range of customer preferences.

One of the standout features of the L900 series is its impressive heating capacity. With up to 30,000 BTUs, these fireplaces can efficiently warm large areas, making them an exceptional choice for both residential and commercial settings. Their exceptional airflow and heat distribution ensure that users enjoy a cozy ambience throughout the space.

The L900 models are integrated with cutting-edge technology that enhances user experience. The advanced electronic ignition ensures reliable start-ups, while the variable flame height adjustment provides flexibility, allowing users to customize the heat output according to their needs. The inclusion of an optional remote control system adds an extra layer of convenience, enabling homeowners to operate the fireplace from anywhere in the room.

Aesthetic appeal is also a major highlight of the Regency L900 series. The full-view glass front maximizes the viewing area, allowing users to enjoy the mesmerizing flames fully. The sleek, contemporary design can easily complement various interior styles, from modern to traditional settings. Moreover, with several customizable options, including media choices such as glass, pebbles, or logs, users can personalize their fireplace to suit their decor.

Safety is always a priority with Regency products. The L900 models come equipped with a safety shut-off valve that activates in case of any irregularities, providing peace of mind for users. Additionally, the fireplace’s direct venting system ensures that combustion gases are safely expelled outside, allowing for effective ventilation without compromising indoor air quality.

Durability is another significant characteristic of the Regency L900 series. Constructed from high-quality materials, these fireplaces promise longevity and resilience, ensuring they can withstand the test of time.

Overall, the Regency L900-NG and L900-LP gas fireplaces stand out for their combination of performance, efficiency, and style. With their advanced features, customizable options, and focus on safety, they provide an enticing heating solution for any home or business, merging warmth with a touch of elegance.