Regency L900-LP Conversion KIT #546-969 from NG to LP, LP Conversion Kit Contains Qty Description

Page 28

INSTALLATION

INSTALLATION

CONVERSION KIT #546-969 FROM NG TO LP

LP Conversion instructions for BEFORE UNIT INSTALLATION.

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER, IF IN DOUBT DO NOT DO THIS CONVERSION!!

LP Conversion Kit Contains:

Qty.

Part #

Description

1

910-462

LP Conversion Coil

1

904-573

Cable Tie

1

910-037

LP Pilot Orifice

1

904-641

Orifice #50 (back)

1

904-241

Orifice #56 (front)

1

904-529

Allen Key

1

918-590

LP Conversion Decal

1

908-528

Red Propane Label

1918-608 Instruction Sheet

1)Remove the glass door.

a.Release the 2 door latches on the left and right side at the top of the firebox.

b. Swing the door out from the top and release the hinges on the left and right side of the door by lifting them up.

Hinge

Door

 

Front Burner Removed

c. Place the door on a soft surface to prevent

4) Remove the back burner by removing the

screw.

scratching.

 

2) Remove the grate by undoing the 2 screws

 

on the right and left side.

 

Latch Location

Latch

Grate

Back Burner

5)Remove the rear log stand by removing the 4 screws.

Rear Log Stand

3)Remove the front burner by removing the screw.

Front Burner

28

Regency® L900 Direct Vent Gas Fireplace

Image 28
Contents Libertytm L900 Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Copy of Safety DecalListed Vented GAS Fireplace Heater Certified for / Certifiée pour Canada and U.S.ARequirements MA Code CO DetectorUnit Dimensions Installation General Safety InformationInstallation Checklist Important Message Save These InstructionsHeat Release KIT Hearth RequirementsManufactured Mobile Home Additional Requirements Locating Your GAS FireplaceClearances Mantel Clearances Mantel LEG ClearancesFraming & Finishing DiagramMaterial Unit Assembly Prior to InstallationVenting Introduction Vent Restrictor PositionLatch Location Vent Restrictor PlateExterior Vent Termination Requirements = Clearance to permanently closed window *min /30cmHorizontal Termination Flex Venting ArrangementsFPI Kit # Length Contains Rigid Pipe Venting Systems Basic Horizontal & Vertical Terminations8 Rigid Pipe Cross Reference Chart 58DVA-16ABL676 & L900 Direct Vent Fireplace Vent Restrictor Setting Allowable Horizontal TerminationsHorizontal Venting with Two 2 90o Elbows Vertical Venting with Three 3 90o Elbows Allowable Vertical Terminations Unit Installation with Horizontal Termination Unit Installation With Vertical Termination This allows for small adjustmentsDiagram Minimum VentUnit Installation Astrocap XLGAS Line L900-NG System DataL900-LP System Data SIT 825 Valve DescriptionBACK-UP Battery Installation Hinge Door Heat Shield Power ModulePower Module Heat Shield Latch LocationConversion KIT #546-969 from NG to LP LP Conversion Kit Contains Qty DescriptionPilot Shield Heat Using a flat head screw driverClip Heat Shield J9 Jumper Location Unplug the power source Hinge DoorHeat Shield Bracket Heat ShieldModulating Coil Wires Bottom Brick PanelValve Tray Valve Tray Slightly RemovedPilot Shield ClipCable Tie J9 JumperBrick Panel Installation Handle with care. do not Force Into PositionF t Side Brick Panel Back Brick Panel Top Brick PanelOuterbox of Firebox Right Side Brick Panel03-42 LOG SET Installation03-42 03-41 03-43 Burner Tube03-44 03-45 03-41 03-43Aeration Adjustment Wiring DiagramLighting Procedure Operating InstructionsMatching Remote Handset & Control BOX ID Code Operating InstructionsOperation During Power Outage Shutdown ProcedureNormal Operating Sounds GAS Appliances STOP! Read the safety information above on this label Copy of Lighting Plate InstructionsMaintenance Heat Shield BACK-UP Battery ReplacementBracket Hinge Heat Door Power Module Replacement Bracket Heat ShieldBracket Hinge Heat Control Module ReplacementControl Module Battery Cover DC Sparker ReplacementHeat Shield Replace the DC sparker Valve Tray Replacement Unplug the power sourceWires Bottom Brick PanelModulating Coil Valve Tray Slightly Removed Valve TrayMain Assembly Parts ListDescription Parts List Burner & LOG Assembly Regency L900 Direct Vent Gas Fireplace Regency L900 Direct Vent Gas Fireplace Regency L900 Direct Vent Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information

L900-LP, L900-NG specifications

The Regency L900-NG and L900-LP are remarkable gas fireplaces that epitomize both elegance and efficiency, bringing a blend of modern technology and traditional aesthetics to any living space. Designed for versatility, these units are suitable for homes with natural gas (NG) or propane (LP) gas lines, thus catering to a wide range of customer preferences.

One of the standout features of the L900 series is its impressive heating capacity. With up to 30,000 BTUs, these fireplaces can efficiently warm large areas, making them an exceptional choice for both residential and commercial settings. Their exceptional airflow and heat distribution ensure that users enjoy a cozy ambience throughout the space.

The L900 models are integrated with cutting-edge technology that enhances user experience. The advanced electronic ignition ensures reliable start-ups, while the variable flame height adjustment provides flexibility, allowing users to customize the heat output according to their needs. The inclusion of an optional remote control system adds an extra layer of convenience, enabling homeowners to operate the fireplace from anywhere in the room.

Aesthetic appeal is also a major highlight of the Regency L900 series. The full-view glass front maximizes the viewing area, allowing users to enjoy the mesmerizing flames fully. The sleek, contemporary design can easily complement various interior styles, from modern to traditional settings. Moreover, with several customizable options, including media choices such as glass, pebbles, or logs, users can personalize their fireplace to suit their decor.

Safety is always a priority with Regency products. The L900 models come equipped with a safety shut-off valve that activates in case of any irregularities, providing peace of mind for users. Additionally, the fireplace’s direct venting system ensures that combustion gases are safely expelled outside, allowing for effective ventilation without compromising indoor air quality.

Durability is another significant characteristic of the Regency L900 series. Constructed from high-quality materials, these fireplaces promise longevity and resilience, ensuring they can withstand the test of time.

Overall, the Regency L900-NG and L900-LP gas fireplaces stand out for their combination of performance, efficiency, and style. With their advanced features, customizable options, and focus on safety, they provide an enticing heating solution for any home or business, merging warmth with a touch of elegance.