Regency L900-NG, L900-LP installation manual Burner Tube, 03-44, 03-45 03-41 03-43

Page 37

INSTALLATION

5) Place the left end of log 03-43 into the pin while fitting the notch

8) Spread all of the Embers on the bottom brick panel around the burner

onto the burner tube. Slide the right end of the log forward until it is

tube and on the inside of the grate as shown.

approximately 3/8" away from the back side of the grate.

 

03-43

Embers on bottom brick panel.

Burner Tube

6)Line up the two holes on the underside of log 03-44 with the pins on logs 03-41 and 03-42 and fit in place.

03-44

Embers on inside of grate.

03-41

9) Spread the vermiculite on the base brick panel covering the remaining exposed base brick.

03-42

7)Line up the two holes on the underside of log 03-45 with the pins on logs 03-41 and 03-43 and fit in place.

03-45

03-41

03-43

INSTALLATION

Regency® L900 Direct Vent Gas Fireplace

37

Image 37
Contents Libertytm L900 Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale Manufactured Mobile Home RequirementsTable of Contents Copy of Safety Decal Safety LabelListed Vented GAS Fireplace Heater Certified for / Certifiée pour Canada and U.S.AMA Code CO Detector RequirementsUnit Dimensions General Safety Information InstallationInstallation Checklist Important Message Save These InstructionsHearth Requirements Heat Release KITManufactured Mobile Home Additional Requirements Locating Your GAS FireplaceClearances Mantel LEG Clearances Mantel ClearancesFraming & Finishing DiagramMaterial Prior to Installation Unit AssemblyVent Restrictor Position Venting IntroductionLatch Location Vent Restrictor Plate= Clearance to permanently closed window *min /30cm Exterior Vent Termination RequirementsHorizontal Termination Flex Venting ArrangementsFPI Kit # Length Contains Basic Horizontal & Vertical Terminations Rigid Pipe Venting Systems58DVA-16AB 8 Rigid Pipe Cross Reference ChartL676 & L900 Direct Vent Fireplace Allowable Horizontal Terminations Vent Restrictor SettingHorizontal Venting with Two 2 90o Elbows Vertical Venting with Three 3 90o Elbows Allowable Vertical Terminations Unit Installation with Horizontal Termination This allows for small adjustments Unit Installation With Vertical TerminationDiagram Minimum VentAstrocap XL Unit InstallationL900-NG System Data GAS LineL900-LP System Data SIT 825 Valve DescriptionHinge Door Heat Shield Power Module BACK-UP Battery InstallationPower Module Heat Shield Latch LocationLP Conversion Kit Contains Qty Description Conversion KIT #546-969 from NG to LPPilot Shield Heat Using a flat head screw driverClip Heat Shield J9 Jumper Location Hinge Door Unplug the power sourceHeat Shield Bracket Heat ShieldBottom Brick Panel Modulating Coil WiresValve Tray Valve Tray Slightly RemovedClip Pilot ShieldCable Tie J9 Jumper Handle with care. do not Force Into Position Brick Panel InstallationTop Brick Panel F t Side Brick Panel Back Brick PanelOuterbox of Firebox Right Side Brick Panel03-42 LOG SET Installation03-42 03-41 Burner Tube 03-4303-44 03-45 03-41 03-43Wiring Diagram Aeration AdjustmentOperating Instructions Lighting ProcedureMatching Remote Handset & Control BOX ID Code Operating InstructionsOperation During Power Outage Shutdown ProcedureNormal Operating Sounds GAS Appliances Copy of Lighting Plate Instructions STOP! Read the safety information above on this labelMaintenance Heat Shield BACK-UP Battery ReplacementBracket Hinge Heat Door Bracket Heat Shield Power Module ReplacementBracket Hinge Heat Control Module ReplacementControl Module Battery Cover DC Sparker ReplacementHeat Shield Replace the DC sparker Unplug the power source Valve Tray ReplacementBottom Brick Panel WiresModulating Coil Valve Tray Slightly Removed Valve TrayMain Assembly Parts ListDescription Parts List Burner & LOG Assembly Regency L900 Direct Vent Gas Fireplace Regency L900 Direct Vent Gas Fireplace Regency L900 Direct Vent Gas Fireplace Warranty Limited Lifetime WarrantyInstaller Please complete the following information