Regency L900-LP, L900-NG Heat Release KIT, Hearth Requirements, Locating Your GAS Fireplace

Page 8

INSTALLATION

INSTALLATION

11)Install standard and optional features. Refer to the following sections:

a)Interior Brick Panels

b)Log Set

c)Exterior Brick Panels

d)Remote Control - refer to "Matching Remote Handset & Control Box ID Code" section.

12)Final check.

Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly and operation fully explained to customer.

This includes:

A)Flat on Wall

B)Flat on Wall Corner

C)Recessed into Wall/Alcove

D)Corner

Diagram 1

HEAT RELEASE KIT

The Heat Release Kit expels warm air from the

replace to the outside of the building, allowing the fireplace to be operated with less heat entering the room. The kit may be used on either the left or right side.

SeeHeatReleaseinstallationmanualforcomplete details and clearances from side only.

HEARTH

REQUIREMENTS

Aminimum 33-1/8" (838mm) wide x 12" (305mm) deep x 2" (51mm) thick non-combustible hearth

1)Clocking the appliance to ensure the correct fi ring rate (rate noted on label 48,000 (NG) Btu/h, 46,500 (LP) Btu/h) after burning appliance for 15 minutes.

2)If required, adjusting the primary air to ensure that the fl ame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

1)Ensure that structural members are not cut or weakened during installation.

2)Ensure proper grounding using the #8 ground lug provided. See "Wiring Diagram" section.

LOCATING YOUR

GAS FIREPLACE

1)When selecting a location for your fi replace, ensure that the clearances are met.

2)The appliance must be installed on a fl at, solid, continuous surface (e.g. wood, metal, concrete). This may be the fl oor, or raised up on a platform to enhance its visual impact. The appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

3)The L900 Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A, B, C and D. See Diagram 1.

4)This appliance is Listed for bedroom installations using the standard FireWizard Remote (millivolt thermostat system). Some areas may have further requirements, check local codes before installation.

5)The L900 Direct Vent Gas Fireplace is approved for alcove installations, see "Clearances" section for details.

6)We recommendthatyouplanyourinstallation on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have an authorized inspector, dealer, or installer review your plans before installation.

Note: For vent terminations refer to "ExteriorVent TerminationLocations" section.

HEATWAVE

DUCT KIT

The HeatWave Air Duct Kit increases the effectiveness of your fi replace by dispersing warm air from the fi replace to remote locations in the same room or other rooms in your home.

Up to two kits may be installed on the fi replace. Please Note: Only 1 HeatWave kit may be operated at one time.

See HeatWave installation manual for complete details and clearances from side only.

The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details.

is required if the fi nished fl oor is not fl ush with the base of the unit. The maximum height between the fi nished fl oor and sub-fl oor is 1" (25mm).

 

-1/8"

(838mm)

 

 

12"

33

 

 

 

(305mm)

 

 

2” (51mm)

NOTE: No hearth is required when the unit is fl ush with the fi nished fl oor as shown below.

The minimum fl oor clearance must be maintained from the top surface of the carpet, etc. to the unit base.

8

Regency® L900 Direct Vent Gas Fireplace

Image 8
Contents Libertytm L900 Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Copy of Safety DecalListed Vented GAS Fireplace Heater Certified for / Certifiée pour Canada and U.S.ARequirements MA Code CO DetectorUnit Dimensions Installation General Safety InformationInstallation Checklist Important Message Save These InstructionsHeat Release KIT Hearth RequirementsManufactured Mobile Home Additional Requirements Locating Your GAS FireplaceClearances Mantel Clearances Mantel LEG ClearancesMaterial DiagramFraming & Finishing Unit Assembly Prior to InstallationVenting Introduction Vent Restrictor PositionLatch Location Vent Restrictor PlateExterior Vent Termination Requirements = Clearance to permanently closed window *min /30cmFPI Kit # Length Contains Venting ArrangementsHorizontal Termination Flex Rigid Pipe Venting Systems Basic Horizontal & Vertical Terminations8 Rigid Pipe Cross Reference Chart 58DVA-16ABL676 & L900 Direct Vent Fireplace Vent Restrictor Setting Allowable Horizontal TerminationsHorizontal Venting with Two 2 90o Elbows Vertical Venting with Three 3 90o Elbows Allowable Vertical Terminations Unit Installation with Horizontal Termination Unit Installation With Vertical Termination This allows for small adjustmentsDiagram Minimum VentUnit Installation Astrocap XLGAS Line L900-NG System DataL900-LP System Data SIT 825 Valve DescriptionBACK-UP Battery Installation Hinge Door Heat Shield Power ModulePower Module Heat Shield Latch LocationConversion KIT #546-969 from NG to LP LP Conversion Kit Contains Qty DescriptionClip Heat Shield Using a flat head screw driverPilot Shield Heat J9 Jumper Location Unplug the power source Hinge DoorHeat Shield Bracket Heat ShieldModulating Coil Wires Bottom Brick PanelValve Tray Valve Tray Slightly RemovedPilot Shield ClipCable Tie J9 JumperBrick Panel Installation Handle with care. do not Force Into PositionF t Side Brick Panel Back Brick Panel Top Brick PanelOuterbox of Firebox Right Side Brick Panel03-42 03-41 LOG SET Installation03-42 03-43 Burner Tube03-44 03-45 03-41 03-43Aeration Adjustment Wiring DiagramLighting Procedure Operating InstructionsMatching Remote Handset & Control BOX ID Code Operating InstructionsNormal Operating Sounds GAS Appliances Shutdown ProcedureOperation During Power Outage STOP! Read the safety information above on this label Copy of Lighting Plate InstructionsMaintenance Bracket Hinge Heat Door BACK-UP Battery ReplacementHeat Shield Power Module Replacement Bracket Heat ShieldControl Module Control Module ReplacementBracket Hinge Heat Heat Shield Replace the DC sparker DC Sparker ReplacementBattery Cover Valve Tray Replacement Unplug the power sourceWires Bottom Brick PanelModulating Coil Valve Tray Slightly Removed Valve TrayDescription Parts ListMain Assembly Parts List Burner & LOG Assembly Regency L900 Direct Vent Gas Fireplace Regency L900 Direct Vent Gas Fireplace Regency L900 Direct Vent Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information

L900-LP, L900-NG specifications

The Regency L900-NG and L900-LP are remarkable gas fireplaces that epitomize both elegance and efficiency, bringing a blend of modern technology and traditional aesthetics to any living space. Designed for versatility, these units are suitable for homes with natural gas (NG) or propane (LP) gas lines, thus catering to a wide range of customer preferences.

One of the standout features of the L900 series is its impressive heating capacity. With up to 30,000 BTUs, these fireplaces can efficiently warm large areas, making them an exceptional choice for both residential and commercial settings. Their exceptional airflow and heat distribution ensure that users enjoy a cozy ambience throughout the space.

The L900 models are integrated with cutting-edge technology that enhances user experience. The advanced electronic ignition ensures reliable start-ups, while the variable flame height adjustment provides flexibility, allowing users to customize the heat output according to their needs. The inclusion of an optional remote control system adds an extra layer of convenience, enabling homeowners to operate the fireplace from anywhere in the room.

Aesthetic appeal is also a major highlight of the Regency L900 series. The full-view glass front maximizes the viewing area, allowing users to enjoy the mesmerizing flames fully. The sleek, contemporary design can easily complement various interior styles, from modern to traditional settings. Moreover, with several customizable options, including media choices such as glass, pebbles, or logs, users can personalize their fireplace to suit their decor.

Safety is always a priority with Regency products. The L900 models come equipped with a safety shut-off valve that activates in case of any irregularities, providing peace of mind for users. Additionally, the fireplace’s direct venting system ensures that combustion gases are safely expelled outside, allowing for effective ventilation without compromising indoor air quality.

Durability is another significant characteristic of the Regency L900 series. Constructed from high-quality materials, these fireplaces promise longevity and resilience, ensuring they can withstand the test of time.

Overall, the Regency L900-NG and L900-LP gas fireplaces stand out for their combination of performance, efficiency, and style. With their advanced features, customizable options, and focus on safety, they provide an enticing heating solution for any home or business, merging warmth with a touch of elegance.