Regency L900-LP, L900-NG installation manual Aeration Adjustment, Wiring Diagram

Page 38

INSTALLATION

INSTALLATION

AERATION

ADJUSTMENT

The burner aeration is factory set but may need

Minimum Air Shutter Opening:

CAUTION: Carbon will be produced if air shutter

adjusting due to either the local gas supply or

NG

Front Burner

1/4"

is tightly closed.

altitude. Open the air shutter for a blue fl ame or

 

close for a more yellow fl ame.

 

Rear Burner

1/2"

Note: Any damage due to carboning

 

LP

Front Burner

1/4"

resulting from improperly setting

In order to adjust the aeration, the logs, grate

the aeration controls is NOT covered

and burners will need to be removed to be able

 

Rear Burner

3/8"

under warranty.

to access the shutters.

 

 

 

 

A receptacle is provided on the left hand side of the unit. 120 Volt AC power must be wired to the receptacle and the control module plugged in for the unit to operate fully. The front and rear burners will operate on low, when the unit is running on battery back-up.

WIRING DIAGRAM

(Do not cut the ground terminal off under any circumstances.)

Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

38

Regency® L900 Direct Vent Gas Fireplace

Image 38
Contents Libertytm L900 Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Listed Vented GAS Fireplace Heater Safety LabelCopy of Safety Decal Certified for / Certifiée pour Canada and U.S.ARequirements MA Code CO DetectorUnit Dimensions Installation Checklist InstallationGeneral Safety Information Important Message Save These InstructionsManufactured Mobile Home Additional Requirements Heat Release KITHearth Requirements Locating Your GAS FireplaceClearances Mantel Clearances Mantel LEG ClearancesMaterial DiagramFraming & Finishing Unit Assembly Prior to InstallationLatch Location Venting IntroductionVent Restrictor Position Vent Restrictor PlateExterior Vent Termination Requirements = Clearance to permanently closed window *min /30cmFPI Kit # Length Contains Venting ArrangementsHorizontal Termination Flex Rigid Pipe Venting Systems Basic Horizontal & Vertical Terminations8 Rigid Pipe Cross Reference Chart 58DVA-16ABL676 & L900 Direct Vent Fireplace Vent Restrictor Setting Allowable Horizontal TerminationsHorizontal Venting with Two 2 90o Elbows Vertical Venting with Three 3 90o Elbows Allowable Vertical Terminations Unit Installation with Horizontal Termination Diagram Unit Installation With Vertical TerminationThis allows for small adjustments Minimum VentUnit Installation Astrocap XLL900-LP System Data GAS LineL900-NG System Data SIT 825 Valve DescriptionPower Module BACK-UP Battery InstallationHinge Door Heat Shield Power Module Heat Shield Latch LocationConversion KIT #546-969 from NG to LP LP Conversion Kit Contains Qty DescriptionClip Heat Shield Using a flat head screw driverPilot Shield Heat J9 Jumper Location Heat Shield Unplug the power sourceHinge Door Bracket Heat ShieldValve Tray Modulating Coil WiresBottom Brick Panel Valve Tray Slightly RemovedCable Tie Pilot ShieldClip J9 JumperBrick Panel Installation Handle with care. do not Force Into Position Outerbox of Firebox F t Side Brick Panel Back Brick Panel Top Brick Panel Right Side Brick Panel03-42 03-41 LOG SET Installation03-42 03-44 03-43Burner Tube 03-45 03-41 03-43Aeration Adjustment Wiring DiagramMatching Remote Handset & Control BOX ID Code Lighting ProcedureOperating Instructions Operating InstructionsNormal Operating Sounds GAS Appliances Shutdown ProcedureOperation During Power Outage STOP! Read the safety information above on this label Copy of Lighting Plate InstructionsMaintenance Bracket Hinge Heat Door BACK-UP Battery ReplacementHeat Shield Power Module Replacement Bracket Heat ShieldControl Module Control Module ReplacementBracket Hinge Heat Heat Shield Replace the DC sparker DC Sparker ReplacementBattery Cover Valve Tray Replacement Unplug the power sourceModulating Coil Valve Tray Slightly Removed WiresBottom Brick Panel Valve TrayDescription Parts ListMain Assembly Parts List Burner & LOG Assembly Regency L900 Direct Vent Gas Fireplace Regency L900 Direct Vent Gas Fireplace Regency L900 Direct Vent Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information