Regency L900-NG, L900-LP installation manual Valve Tray Replacement, Unplug the power source

Page 47

MAINTENANCE

VALVE TRAY REPLACEMENT

1)Remove the exterior brick panels.

2)Remove the glass door.

a.Release the 2 door latches on the left and right side at the top of the fi rebox.

Latch Location

Latch

3)Loosen the 2 screws that hold the left side heat shield in place.

Heat

Shield

4)Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket (located directly above the heat shield).

Bracket

9)Remove the front burner by removing the screw.

Front Burner

Front Burner Removed

b.Swingthedooroutfromthetopandrelease the hinges on the left and right side of the door by lifting them up.

Heat

Shield

Hinge

Door

5) Unplug the power source.

6) Remove the log set.

7) Remove the interior brick panels.

8) Remove the grate by undoing the 2 screws on the right and left side.

c.Place the door on a soft surface to prevent scratching.

10)Remove the back burner by removing the screw.

Back Burner

11)Remove the rear log stand by removing the 4 screws.

MAINTENANCE

Rear Log Stand

Grate

Regency® L900 Direct Vent Gas Fireplace

47

Image 47
Contents Libertytm L900 Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale Manufactured Mobile Home RequirementsTable of Contents Certified for / Certifiée pour Canada and U.S.A Safety LabelCopy of Safety Decal Listed Vented GAS Fireplace HeaterMA Code CO Detector RequirementsUnit Dimensions Important Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistLocating Your GAS Fireplace Heat Release KITHearth Requirements Manufactured Mobile Home Additional RequirementsClearances Mantel LEG Clearances Mantel ClearancesMaterial DiagramFraming & Finishing Prior to Installation Unit AssemblyVent Restrictor Plate Venting IntroductionVent Restrictor Position Latch Location= Clearance to permanently closed window *min /30cm Exterior Vent Termination RequirementsFPI Kit # Length Contains Venting ArrangementsHorizontal Termination Flex Basic Horizontal & Vertical Terminations Rigid Pipe Venting Systems58DVA-16AB 8 Rigid Pipe Cross Reference ChartL676 & L900 Direct Vent Fireplace Allowable Horizontal Terminations Vent Restrictor SettingHorizontal Venting with Two 2 90o Elbows Vertical Venting with Three 3 90o Elbows Allowable Vertical Terminations Unit Installation with Horizontal Termination Minimum Vent Unit Installation With Vertical TerminationThis allows for small adjustments DiagramAstrocap XL Unit InstallationSIT 825 Valve Description GAS LineL900-NG System Data L900-LP System DataHeat Shield Latch Location BACK-UP Battery InstallationHinge Door Heat Shield Power Module Power ModuleLP Conversion Kit Contains Qty Description Conversion KIT #546-969 from NG to LPClip Heat Shield Using a flat head screw driverPilot Shield Heat J9 Jumper Location Bracket Heat Shield Unplug the power sourceHinge Door Heat ShieldValve Tray Slightly Removed Modulating Coil WiresBottom Brick Panel Valve TrayJ9 Jumper Pilot ShieldClip Cable TieHandle with care. do not Force Into Position Brick Panel InstallationRight Side Brick Panel F t Side Brick Panel Back Brick PanelTop Brick Panel Outerbox of Firebox03-42 03-41 LOG SET Installation03-42 03-45 03-41 03-43 03-43Burner Tube 03-44Wiring Diagram Aeration AdjustmentOperating Instructions Lighting ProcedureOperating Instructions Matching Remote Handset & Control BOX ID CodeNormal Operating Sounds GAS Appliances Shutdown ProcedureOperation During Power Outage Copy of Lighting Plate Instructions STOP! Read the safety information above on this labelMaintenance Bracket Hinge Heat Door BACK-UP Battery ReplacementHeat Shield Bracket Heat Shield Power Module ReplacementControl Module Control Module ReplacementBracket Hinge Heat Heat Shield Replace the DC sparker DC Sparker ReplacementBattery Cover Unplug the power source Valve Tray ReplacementValve Tray WiresBottom Brick Panel Modulating Coil Valve Tray Slightly RemovedDescription Parts ListMain Assembly Parts List Burner & LOG Assembly Regency L900 Direct Vent Gas Fireplace Regency L900 Direct Vent Gas Fireplace Regency L900 Direct Vent Gas Fireplace Warranty Limited Lifetime WarrantyInstaller Please complete the following information

L900-LP, L900-NG specifications

The Regency L900-NG and L900-LP are remarkable gas fireplaces that epitomize both elegance and efficiency, bringing a blend of modern technology and traditional aesthetics to any living space. Designed for versatility, these units are suitable for homes with natural gas (NG) or propane (LP) gas lines, thus catering to a wide range of customer preferences.

One of the standout features of the L900 series is its impressive heating capacity. With up to 30,000 BTUs, these fireplaces can efficiently warm large areas, making them an exceptional choice for both residential and commercial settings. Their exceptional airflow and heat distribution ensure that users enjoy a cozy ambience throughout the space.

The L900 models are integrated with cutting-edge technology that enhances user experience. The advanced electronic ignition ensures reliable start-ups, while the variable flame height adjustment provides flexibility, allowing users to customize the heat output according to their needs. The inclusion of an optional remote control system adds an extra layer of convenience, enabling homeowners to operate the fireplace from anywhere in the room.

Aesthetic appeal is also a major highlight of the Regency L900 series. The full-view glass front maximizes the viewing area, allowing users to enjoy the mesmerizing flames fully. The sleek, contemporary design can easily complement various interior styles, from modern to traditional settings. Moreover, with several customizable options, including media choices such as glass, pebbles, or logs, users can personalize their fireplace to suit their decor.

Safety is always a priority with Regency products. The L900 models come equipped with a safety shut-off valve that activates in case of any irregularities, providing peace of mind for users. Additionally, the fireplace’s direct venting system ensures that combustion gases are safely expelled outside, allowing for effective ventilation without compromising indoor air quality.

Durability is another significant characteristic of the Regency L900 series. Constructed from high-quality materials, these fireplaces promise longevity and resilience, ensuring they can withstand the test of time.

Overall, the Regency L900-NG and L900-LP gas fireplaces stand out for their combination of performance, efficiency, and style. With their advanced features, customizable options, and focus on safety, they provide an enticing heating solution for any home or business, merging warmth with a touch of elegance.