Wayne JSU50 operating instructions For Replacement Parts, Call

Page 8

Operating Instructions and Parts Manual

 

 

 

JSU50

For Replacement Parts, Call 1-800-237-0987

Please provide following information:

Address any correspondence to:

- Model number

Wayne Water Systems

- Serial number (if any)

101 Production Drive

 

- Part description and number as shown in parts list

Harrison, OH 45030

U.S.A.

2

 

 

 

 

1

3

5

 

 

 

 

8, 9

 

 

 

 

 

6

7

 

 

12

 

 

 

13

10

 

15

4

 

14

NOTE: Only use factory parts to repair this pump.

Ref.

 

Part

 

Ref.

 

Part

 

No.

Description

No.

Qty.

No.

Description

No.

Qty.

1

Motor

32059-001

1

9

Venturi

17151-002

1

2

Screw

16636-002

4

10

Nozzle

15672

1

3

Square ring rubber gasket

17150-001

1

† 11

3/4” Pipe plug

15921

1

4

Shaft seal assembly

56393

1

12

Pump housing

41033-001

1

5

Impeller

23285-002

1

13

Base

23029-001

1

6

Diffuser

17148-001

1

14

Pressure switch

30010-001

1

7

Screw

17165-001

2

15

Seal Plate

4372-001

1

8

O-ring

15557

1

Not Shown

 

 

Limited Warranty

For one year from the date of purchase, Wayne Water Systems (“Wayne”) will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or workmanship. Please call Wayne (800-237-0987) for instructions or see your dealer. Be prepared to provide the model number when exercising this warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser.

This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance, or failure to operate in accordance with Wayne's written instructions.

THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE. THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED.

Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of incidental or consequential damages, so the above limitations might not apply to you. This limited warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state.

In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall Wayne or its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equipment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer’s customers for such damages.

You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST send a copy of the purchase receipt along with the material or correspondence. Please call Wayne (800-237-0987) for return authorization and instructions.

DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records.

MODEL NO. _____________________ SERIAL NO. ________________________ INSTALLATION DATE _____________________

ATTACH YOUR RECEIPT HERE

www.waynepumps.com

8

Image 8
Contents Safety Guidelines General Safety InformationInstallation DescriptionPump piping installation Operating Instructions and Parts ManualSuction piping Discharge piping FigureConnection to water source Operating Instructions & Parts ManualElectrical connections Maintenance OperationAir pressure check for pre- charged tanks Friction loss chartRecommended Fusing & Wiring Data 60 HZ Motors Troubleshooting Chart Water Supplies OperatingInstructions & Parts ManualFor Replacement Parts, Call Déballage Directives de SécuritéGénéralités Sur La Sécurité PRoposition 65 DE CalifornieInstallation Suite 11-Fr Connexion ÉlectriqueBranchement a la source d’eau 12-Fr FonctionnementAmorçage de la pompe Entretien Tableau de dépannage 14-FrDe Pièces 15-Fr Instructions D’utilisation et ManualInstructions D’utilisation et Manual de PiècesJSU50 16-FrDescripción Para DesempacarMedidas de Seguridad Informaciones Generales de SeguridadInstalación Continúa 19-Sp ConexiÓnes elÉctricasConexiÓn al suministro de agua 20-Sp FuncionamientoCÓmo cebar la bomba Mantenimiento Cómo drenar la bombaCÓmo drenar el tanque Tanques inundadosTabla de Identificación de Problemas 22-Sp23-Sp Piezas Capa FreaticaManantial CisternaNo Envie Estos Datos a WAYNE. Conserve esto sólo como datos 24-Sp