Pitco Frialator L22-303 service manual Electrical ConnectionsJ1, Connection Type Nominal

Page 15

I8 Water Cooker Computer Service

Pitco P/N PP11375

6.0Electrical Connections(J1):

J1

Connection

Type

Nominal

Notes:

 

 

 

 

 

1

24VAC IN

PWR

24VAC

24VAC +20% / -15% 50/60Hz

 

 

 

 

 

2

24VAC COM

PWR

0VAC

AC RETURN

 

 

 

 

 

3

PROBE +

THERMISTOR

Resistance varies with vat temperature. 6.22K

 

 

PROBE

ohms at 212°F.

4

PROBE -

 

 

 

 

 

 

 

5

DVI

INPUT

24VAC/DC

Drain Valve Interlock

 

 

 

 

 

6

HFB

INPUT

24VAC/DC

Heat FeedBack

 

 

 

 

 

7

24VDC COM

PWR

0VDC

DC RETURN

 

 

 

 

 

8

HD

OUTPUT

24VDC

Heat Demand

 

 

 

 

 

9

SO(TRANSFER)

OUTPUT

24VDC

Side On(TRANSFER)

 

 

 

 

 

10

RBL

OUTPUT

24VDC

Right Basket Lift

 

 

 

 

 

11

LBL

OUTPUT

24VDC

Left Basket Lift

 

 

 

 

 

12

FILL DONE

INPUT

24VAC/DC

Fill Done signal

 

 

 

 

 

NOTE: The Diagnostics Menu(sections

4.0and 4.5) can be used to check the inputs and outputs on this connector.

12

9

6

3

11

8

5

2

10

7

4

1

 

J1

 

10

7

4

1

11

8

5

2

12

9

6

3

L22-303 Rev 0 (01/07)

15

Image 15
Contents I8 Water Cooker Computer Table of Contents Control Alarm Displays To turn the appliance OFF To cancel a cookTo Check Actual and Set Temperatures Key Locations and FunctionsTo enter Level 1 Programmingstore manager To set the Cook TemperatureTo enter Level 2 Options Programmingstore manager Shake TimeHold Time Xxx’F, or Filling Fahrenheit or Celcius Temperature DisplayPassword Settings Beeper Volume SettingTo Enter Level 3 Service Programmingservice technician Control or Timer Mode SettingOffset Temperature Setting Diagnostics Menu Cancel Delay SettingMinimum On Cycle Time Setting Cancel Type SettingHeat DemandHD Output Drain SwitchDVI InputLeft Basket LiftLBL Output Right Basket LiftRBL OutputHigh Ready Level Adjustment Recovery Test ValueMore Service Menu Options Low Ready Level AdjustmentDisplay Temperature Average Setting Low Dead Band AdjustmentHigh Dead Band Adjustment Control Temperature Average SettingOpen Probe Alarm Control Alarm DisplaysMinimum Fill Time Setting Filling Pilot Flame Sense Timer AdjustmentSystem Failure Alarm High Temperature AlarmDrain Valve Alarm Heat Failure AlarmConnection Type Nominal Electrical ConnectionsJ1Probe Resistance Chart ResistanceTemp Ohms Physical Dimensions Page Page L22-303 Rev 0 01/07