Pitco Frialator L22-303 Fahrenheit or Celcius Temperature Display, Password Settings

Page 7

I8 Water Cooker Computer Service

Pitco P/N PP11375

3.1Fahrenheit or Celcius Temperature Display:

This control will display temperatures in Fahrenheit(ºF).or Celsius(ºC) degrees. The default setting is degrees Fahrenheit(ºF).

With the control display showing [SELECT ], press product key 1. The display will show [DEGREE n] where n is the current setting, either F or C. Press the 0 key to scroll between the two options. Press the program key to save the setting. The control display will show [PROGRAM ]. Press product key 0 to select more options below(display shows [SELECT ]) or press the program key to return to normal operations(display shows either [READY], [ACT xxx’F], or [FILLING ]).

1

3.2Password Settings:

The factory default setting for this control is password disabled. The default factory password for Level 1 and Level 2 programming is 6684. This default password will always work, regardless of the new password that can be entered using this option.

With the control display showing [SELECT ], press product key 2. The display will show

2

[SET PASS]. Press product key 0 to scroll between the two options [PASS REQ], and

 

 

[NO PASS ]. Press the program key to save this setting. If the [NO PASS ] option was

 

selected, the control display will show [PROGRAM ]. ]. Press product key 0 to select

 

 

more options below(display shows [SELECT ]) or press the program key to return to normal

 

operations(display shows either [READY], [ACT xxx’F], or [FILLING ]). If the [PASS REQ]

 

option was selected, the display will show [PASSxxxx], where xxxx is the current password.

 

Enter the new password using the product keys 0-9. Press the program key. The control display will show [PROGRAM ]. Press product key 0 to select more options below(display shows [SELECT ]) or press the program key to return to normal operation(display shows either [READY], [ACT xxx’F], or [FILLING ]).

3.3Beeper Volume Setting:

The volume setting of the beeper(alarm) can be set to low(1), medium(2) and high(3). The default value for the beeper volume is 3.

With the control display showing [SELECT ], press product key 3. The display will show

3

[VOLUME x] where x is the current volume setting. Press product key 0 to scroll through

the volume options. The control will beep using the volume setting currently shown on the display. Press the program key to save this setting. The control display will show [PROGRAM ]. Press product key 0 to select more options below(display shows [SELECT ]) or press the program key to return to normal operation(display shows either [READY], [ACT xxx’F], or [FILLING ]).

3.4

Language Selection:

 

 

 

This control can display text in English, Spanish, French, German and Dutch.

 

 

With the control display showing [SELECT ], press product key 4. The display will show

 

 

 

 

4

 

 

 

the current language setting of either [ENGLISH], [ESPANOL], [FRANCAIS],

 

 

 

[DEUTSCH], or [HOLLANDS]. Press product key 0 to scroll through the language

 

 

 

options. Press the program key to save this setting. The control display will show

 

 

 

 

 

 

[PROGRAM ]. Press product key 0 to select more options below(display shows [SELECT ]) or

 

 

press the program key to return to normal operation(display shows either [READY], [ACT

 

 

xxx’F], or [FILLING ]).

 

 

L22-303 Rev 0 (01/07)

7

Image 7
Contents I8 Water Cooker Computer Table of Contents Control Alarm Displays To turn the appliance OFF To cancel a cookTo Check Actual and Set Temperatures Key Locations and FunctionsTo enter Level 1 Programmingstore manager To set the Cook TemperatureShake Time To enter Level 2 Options Programmingstore managerHold Time Xxx’F, or Filling Fahrenheit or Celcius Temperature DisplayPassword Settings Beeper Volume SettingControl or Timer Mode Setting To Enter Level 3 Service Programmingservice technicianOffset Temperature Setting Diagnostics Menu Cancel Delay SettingMinimum On Cycle Time Setting Cancel Type SettingHeat DemandHD Output Drain SwitchDVI InputLeft Basket LiftLBL Output Right Basket LiftRBL OutputHigh Ready Level Adjustment Recovery Test ValueMore Service Menu Options Low Ready Level AdjustmentDisplay Temperature Average Setting Low Dead Band AdjustmentHigh Dead Band Adjustment Control Temperature Average SettingOpen Probe Alarm Control Alarm DisplaysMinimum Fill Time Setting Filling Pilot Flame Sense Timer AdjustmentSystem Failure Alarm High Temperature AlarmDrain Valve Alarm Heat Failure AlarmConnection Type Nominal Electrical ConnectionsJ1Resistance Probe Resistance ChartTemp Ohms Physical Dimensions Page Page L22-303 Rev 0 01/07