Pitco Frialator L22-303 To enter Level 2 Options Programmingstore manager, Shake Time, Hold Time

Page 6

I8 Water Cooker Computer Service

Pitco P/N PP11375

To deactivate the cook timer on a product key, enter in a cook time of zero for this key.

2.2.2 Shake Time

Shake Time is an alarm that sounds while a cook timer is running to prompt an operator to shake the product in the basket. The default value for shake time on a product key is zero, which disables this alarm. To enable the shake time alarm, a non-zero value must be entered for this setting. The shake time value must be less than the cook time.

With the display showing [nSH mm:ss] (where n is the desired product key, SH means Shake and mm:ss is the time value in minutes:seconds), enter the new shake time value using the product keys 0-9. NOTE: the time value entered will be the time remaining before the end of the cook.

Press the clock key to save/exit this setting and proceed to the next step(2.2.3) or press the program key three times to exit out of this programming option and return to normal operation.

2.2.3 Hold Time

After a product is cooked, it may stand in bins for a period of time. Hold Time provides a timer to control how long a product stands in a bin. After the hold timer expires, an alarm will sound to inform the operator to cook more product. The default value for hold time on a product key is zero, which disables this alarm/timer. To enable the hold timer/alarm, a non-zero value must be entered for this setting.

With the display showing [nHDh.mm:ss] (where n is the desired product key, HD means Hold and h.mm:ss is the time value in hours.minutes:seconds), enter the new hold time value using the product keys 0-9. Press the program key three times to save and exit out of this programming option. The control display will show either [READY], [ACT xxx’F], or [FILLING ] and the control will return to normal operation.

3.0To enter Level 2 Options Programming(store manager):

Note: The factory default setting for this control does not require an operator password to be entered. However, the operator password requirement and value may be changed in section 3.2. Entry of a password when NOT required will not interfere with the programming process.

While there are no cook timers running, and the control display shows either [READY], [ACT xxx’F], or [FILLING ], press the program key. If the control displays [PASS ], enter the manager password(or the default manager password 6684) using the product keys 0-9. The control display will show [PROGRAM ]. To enter into the Level 2 Options

Menu, press product key 0. The control display will show [SELECT ].

The key indicators that light up will have options that can be adjusted. Any key indicators that do not light up do not have options that can be adjusted.

0

All of the Level 2 Options Menu programming options shown below must begin with the control displaying this prompt [SELECT ].

6

L22-303 Rev 0 (01/07)

Image 6
Contents I8 Water Cooker Computer Table of Contents Control Alarm Displays Key Locations and Functions To cancel a cookTo Check Actual and Set Temperatures To turn the appliance OFFTo set the Cook Temperature To enter Level 1 Programmingstore managerTo enter Level 2 Options Programmingstore manager Shake TimeHold Time Beeper Volume Setting Fahrenheit or Celcius Temperature DisplayPassword Settings Xxx’F, or FillingTo Enter Level 3 Service Programmingservice technician Control or Timer Mode SettingOffset Temperature Setting Cancel Type Setting Cancel Delay SettingMinimum On Cycle Time Setting Diagnostics MenuRight Basket LiftRBL Output Drain SwitchDVI InputLeft Basket LiftLBL Output Heat DemandHD OutputLow Ready Level Adjustment Recovery Test ValueMore Service Menu Options High Ready Level AdjustmentControl Temperature Average Setting Low Dead Band AdjustmentHigh Dead Band Adjustment Display Temperature Average SettingFilling Pilot Flame Sense Timer Adjustment Control Alarm DisplaysMinimum Fill Time Setting Open Probe AlarmHeat Failure Alarm High Temperature AlarmDrain Valve Alarm System Failure AlarmElectrical ConnectionsJ1 Connection Type NominalProbe Resistance Chart ResistanceTemp Ohms Physical Dimensions Page Page L22-303 Rev 0 01/07